Catalog excerpts
ADJUSTABLE AIR AMPLIFIER - HOW IT WORKS: A large volume of surrounding air is induced into the Amplifier at point (A) by the action of a small amount of compressed air which enters the annular chamber at point (B) that is then throttled through a small ring Nozzle at high velocity and into the inside of the Amplifier over a coanda profile. The compressed air stream clings to the coanda profile as it enters the inside walls of the Amplifier and thereby creating a vacuum that induces the outside air converting the pressure into amplified airflow. The amplified airflow leaves at the exit at point (C). Airflow is further amplified downstream at point (D) by entraining additional air from the surroundings at the exit. ADJUSTABLE AIR AMPLIFIER RATIOS (APPROX.) ADJUSTABLE AIR AMPLIFIER SPECIFICATIONS: Normally set to .002” (.05mm) gap if greater air force is required, the gap is adjustable. The first two sizes of adjustable air amplifiers come in two versions – unmarked regular versions and marked to gauge the gap setting from 0 to 1.5 mm. Model 40001, 40001G, 40001S 40002, 40002G, 40002S 40003, 40003S OUTSIDE DIAMETER OF OUTLET LOCK RING *BSP Threads or Adaptors can be supplied depending on country location. ADJUSTABLE AIR AMPLIFIRE E-mail:- sales@nexflow.com sales@nexflowair.com sales@nex-flow.com Web:- www.nexflow.com www.nexflowair.com www.nex-flow.com
Open the catalog to page 140001, 40001G and 40001S AMPLIFICATION RATIO = 15:1 (SEE ADDENDUM - I) Pressure vs. Air Consumption for Model 40001, 40001G and 40001S Adjustable Air Amplifier 140(9.8) Pressure at Inlet of Air Amplifier PSIG (BAR) Air Consumption SCFM (SLPM) Pressure vs. Air Flow At Outlet for Model 40001, 40001G and 40001S Adjustable Air Amplifier Air Flow At Outlet SCFM (SLPM) Nex Flow™ Air Products Corp. 10520 Yonge Street, Unit 35B-220 Richmond Hill, ON, Canada, L4C 3C7 Tel: +1-416-410-1313 Fax: +1-416-410-180 or +1-716-626-3001 Pressure at Inlet of Air Amplifier PSIG (BAR)
Open the catalog to page 2Pressure vs. Velocity At Outlet for Model 40001, 40001G and 40001S Adjustable Air Amplifier Pressure at Inlet of Air Amplifier PSIG (BAR) Velocity At Outlet In ft/min (m/sec) Pressure vs. Velocity 12” From Outlet for Model 40001, 40001G and 40001S Adjustable Air Amplifier Pressure at Inlet of Air Amplifier PSIG (BAR) Velocity 12” From Outlet - Includes Downstream Entrainment In ft/min (m/sec) 36" (914mm) Distance from Outlet Diameter of Flow Pattern E-mail:- sales@nexflow.com sales@nexflowair.com sales@nex-flow.com Web:- www.nexflow.com www.nexflowair.com www.nex-flow.com
Open the catalog to page 340002, 40002G & 40002S AMPLIFICATION RATIO = 16:1 (SEE ADDENDUM - I) Pressure vs. Air Consumption for Model 40002, 40002G & 40002S Adjustable Air Amplifier 140(9.8) Pressure at Inlet of Air Amplifier PSIG (BAR) Air Consumption SCFM (SLPM) Pressure vs. Air Flow At Outlet for Model 40002, 40002G & 40002S Adjustable Air Amplifier Air Flow At Outlet SCFM (SLPM) Nex Flow™ Air Products Corp. 10520 Yonge Street, Unit 35B-220 Richmond Hill, ON, Canada, L4C 3C7 Tel: +1-416-410-1313 Fax: +1-416-410-180 or +1-716-626-3001 Pressure at Inlet of Air Amplifier PSIG (BAR)
Open the catalog to page 4Pressure vs. Velocity At Outlet for Model 40002, 40002G & 40002S Adjustable Air Amplifier Pressure at Inlet of Air Amplifier PSIG (BAR) Velocity At Outlet In ft/min (m/sec) Pressure vs. Velocity 12” From Outlet for 40002, 40002G & 40002S Adjustable Air Amplifier Pressure at Inlet of Air Amplifier PSIG (BAR) Velocity 12” From Outlet - Includes Downstream Entrainment In ft/min (m/sec) 36" (914mm) Distance from Outlet Diameter of Flow Pattern E-mail:- sales@nexflow.com sales@nexflowair.com sales@nex-flow.com Web:- www.nexflow.com www.nexflowair.com www.nex-flow.com
Open the catalog to page 540003 & 40003S AMPLIFICATION RATIO = 17:1 (SEE ADDENDUM - I) Pressure vs. Air Consumption for Model 40003 & 40003S Adjustable Air Amplifier Pressure at Inlet of Air Amplifier PSIG (BAR) Air Consumption SCFM (SLPM) Pressure vs. Air Flow At Outlet for Model 40003 & 40003S Adjustable Air Amplifier 500(14160) Air Flow At Outlet SCFM (SLPM) Nex Flow™ Air Products Corp. 10520 Yonge Street, Unit 35B-220 Richmond Hill, ON, Canada, L4C 3C7 Tel: +1-416-410-1313 Fax: +1-416-410-180 or +1-716-626-3001 Pressure at Inlet of Air Amplifier PSIG (BAR)
Open the catalog to page 6Pressure vs. Velocity At Outlet for Model 40003 & 40003S Adjustable Air Amplifier Pressure at Inlet of Air Amplifier PSIG (BAR) Velocity At Outlet In ft/min (m/sec) Pressure vs. Velocity 12” From Outlet for Model 40003 & 40003S Adjustable Air Amplifier Pressure at Inlet of Air Amplifier PSIG (BAR) Velocity 12” From Outlet - Includes Downstream Entrainment In ft/min (m/sec) 72" (1830mm) Distance from Outlet Diameter of Flow Pattern Model 40003 AIR AMPLIFIER SIZE 4" AIR FLOW CHART E-mail:- sales@nexflow.com sales@nexflowair.com sales@nex-flow.com Web:- www.nexflow.com www.nexflowair.com...
Open the catalog to page 7The Adjustable Air Amplifier can be adjusted to provide the blow-off force and/or vacuum required for any particular application. Made of anodized aluminum or stainless steel for corrosive and high temperature applications the unit offers flexibility in applications. Model 40002S Stainless Steel Adjustable Air Amplifiers cool hot spots on a duct where insulation has worn away until downtime can be scheduled. Model 40001 Adjustable Air Amplifier vents dust from a machining operation. NEXFLOW NEXFLOW DUST COLLECTOR The Gauged Adjustable Air Amplifier with marking to indicate the settings from...
Open the catalog to page 8ADJUSTABLE AIR AMPLIFIERS - ALUMINUM PART NO. 1-1/4” Adjustable Aluminum Air Amplifier 2” Adjustable Aluminum Air Amplifier 4” Adjustable Aluminum Air Amplifier 1-1/4” Adjustable Aluminum Amplifier plus Filter with Auto Drain 2” Adjustable Aluminum Amplifier plus Filter with Auto Drain 4” Adjustable Aluminum Amplifier plus Filter with Auto drain 1-1/4” Adjustable Aluminum Amplifier plus Filter with Auto Drain plus Regulator with Gauge 2” Adjustable Aluminum Amplifier plus Filter with Auto Drain plus Regulator with Gauge 4” Adjustable Aluminum Amplifier plus Filter with Auto Drain plus...
Open the catalog to page 9All Nex Flow Air Products Corp. catalogs and technical brochures
-
AIR NOZZLES AND JETS
4 Pages
-
AIR NOZZLES AND JETS
8 Pages
-
SAFETY AIR BLOW OFF GUNS
3 Pages
-
RING VAC AIR CONVEYOR
14 Pages
-
STATIC ELIMINATORS
24 Pages
-
TM FRIGID-X VORTEX TUBES
15 Pages
-
TM FRIGID-X PANEL COOLER
17 Pages
-
Nexflow Catalog
188 Pages
-
Fume and Dust Extractor
2 Pages
-
Mist Tool Cooling System
2 Pages
-
Mini Coolers
2 Pages
-
Adjustable Spot Coolers
2 Pages
-
Air Knives
26 Pages
-
Air Jets
18 Pages
-
STREAM VAC
8 Pages
-
Accessories
13 Pages
-
FRIGID-X TOOL COOLING SYSTEM
6 Pages
-
FRIGID-X VORTEX TUBES
6 Pages
-
Ion Blaster Beam?
2 Pages
-
nexflow-ebook
174 Pages
-
Tool cooling
4 Pages
-
Vortex tubes
9 Pages
-
Pneumatic Water Seperator
9 Pages
-
Static Bars - VS
3 Pages
-
Ionizing Nozzles
1 Pages
-
Ionizing Air Gun
2 Pages
-
Ion Air Blower
2 Pages
-
Air-Blade™ Ionizer
5 Pages
-
Dry Air Gun System
1 Pages
-
X-Stream™ Hand Vac
2 Pages
-
Reversible Drum Angel
2 Pages
-
Sound Level Meter
1 Pages
-
Air Flow Meter
1 Pages
-
PLC Flow Control
2 Pages
-
Ultrasonic Leak Detector
2 Pages
-
Air Jets
4 Pages
-
Tool Cooling
4 Pages
-
Muffling Kits
1 Pages
-
Panel Cooling
16 Pages
-
Mini Spot Cooler
1 Pages
-
Standard Vortex Tube
9 Pages
-
Easy Grip Blowoff Guns
2 Pages
-
Ring-Blade™ Air Wipe
4 Pages
-
X-Stream™ Heavy Duty Ring-Vac™
4 Pages
-
X-Stream™ Air-Blade
26 Pages
-
Air-Blade™ Air Knife
10 Pages
-
Air Amplifier
13 Pages
-
Fixed Air Amplifiers
2 Pages
Archived catalogs
-
X-Stream? Air Nozzles
16 Pages
-
Adjustable Air Amplifier
2 Pages