1. Catalogs
  2. Newtons4th Ltd.
  3. Compact Power Analyzers PPA500Series, PPA1500Series

Compact Power Analyzers PPA500Series, PPA1500Series

Compact Power Analyzers PPA500Series, PPA1500Series

Compact Power Analyzers PPA500Series, PPA1500Series

Product catalog summary
Overview of PPA500 and PPA1500 Series Power Analyzers
Specifications: The PPA500 series offers high accuracy with a basic accuracy of 0.05% and a frequency range from DC to 500kHz, while the PPA1500 extends to 1MHz. Both series feature a fast sample rate of 1M samples/s and phase accuracy of 0.005 degrees plus 0.01 degrees per kHz.
Features: The PPA1500 includes an oscilloscope and graphical datalog display. Both series support interfaces like RS232, USB, and optional LAN and GPIB, with PC software for remote control and data monitoring.
Measurement Capabilities: The PPA5xx series functions as a power analyzer, true RMS voltmeter, power integrator, and harmonic analyzer. The PPA15xx adds an oscilloscope, phase meter, and impedance meter.
Real-Time Analysis: Both series use real-time no-gap analysis to prevent data loss during measurements, essential for asynchronous waveform analysis.
Applications: Suitable for standby power measurement (IEC62301/EN50564) and AC-DC power supply efficiency testing, meeting standards by the U.S. EPA and California Energy Commission.
Accessories: Includes high-performance voltage attenuating probes and external current measurement options for a wide range of measurements.
Calibration and Certification: UKAS calibration certificates are provided, ensuring accuracy across the frequency range, with global re-calibration services available.
Technical Specifications: Detailed specs include frequency range, voltage and current input ranges, accuracy, phase accuracy, power accuracy, and communication ports. Memory capacity is 16,000 records.
Specifications: The voltage attenuator and external inputs have an input impedance of 1MΩ || 30pF, a 480x272 dot full-color TFT display, and dimensions of 92H×215W×312D mm. Safety isolation is rated at 1000Vrms or DC (CATII) and 600Vrms or DC (CATIII). Power supply operates at 90 to 265Vrms, 50 to 60Hz, with a maximum of 35VA.
Operating Conditions: Optimal operation at 23˚C ± 5˚C, with a non-condensing relative humidity of 20-90%. Temperature coefficient is ±0.01% per ˚C of reading between 5-18˚C and 28-40˚C.
Voltage Attenuator Overload Capability: Overload capability is 20mS at 2.5KV PK (1.5KV rms), 5Sec at 2.5KV PK (1.1KV rms), and continuous at 2.5KV PK (1.0KV rms).
Company Information: Newtons4th Ltd, established in 1997, specializes in phase measurement test equipment, is ISO9001 registered, and received the "Innovation 2010" Queen's award for enterprise.
Product Range: Includes Frequency Response and Impedance Analyzers, Selective Level Meters, and Laboratory Power Amplifiers, with applications in power supply phase margin and gain margin (FRA), inductance, capacitance, and resistance (LCR), mechanical vibration analysis (HARM), and phase angle voltmeter (PAV).
Product Comparison: Compares models (PPA500, PPA1500, PPA3500, PPA4500, PPA5500) based on accuracy, phase options, bandwidth, voltage input, direct current input, features, and dimensions. Key features include USB memory port, LAN port, GPIB port, RS232 port, real-time clock, and internal datalogging.
Contact Information: Newtons4th Ltd is located at 1 Bede Island Road, Leicester, UK. Contact via phone at +44 (0)116 230 1066, fax at +44 (0)116 230 1061, or email at [email protected].
See more

Catalog excerpts

Compact Power Analyzers PPA500Series, PPA1500Series-1

Compact Power Analyzers PPA500Series PPA1500Series High Accuracy - Low Cost Leading wideband accuracy Basic 0.05% with class leading high frequency performance Oscilloscope/Graphical Display PPA1500 features Oscilloscope and graphical datalog display Wide frequency range DC, 10mHz to 1MHz (DC, 10mHz to 500kHz PPA500) Fast sample rate and No-Gap 1M samples/s - High accuracy in noisy applications Leading phase accuracy 0.005 degrees plus 0.01 degrees per kHz Built in high precision current shunt 20Arms 300Apk or 30Arms 1000Apk direct plus a wide range of external sensors Versatile interfaces RS232, USB and optional LAN(Standard on PPA1500), GPIB Range of PC software options Remote control, monitoring and recording of real time data, tables and graphs

 Open the catalog to page 1
Compact Power Analyzers PPA500Series, PPA1500Series-2

PO.tR ««IYZER I IAong«i XXX/ Aang# 1/3 coictagt FRONT VIEW © SCREEN DISPLAY OPTIONS PPA5xx: Zoom, Real time and Table PPA15xx: Zoom, Real Time, Table, Graph PPA5xx: POWER ANALYZER, TRUE RMS VOLTMETER, POWER INTEGRATOR, HARMONIC ANALYZER PPA15xx: POWER ANALYZER, HARMONIC ANALYZER, TRUE RMS VOLTMETER, OSCILLOSCOPE Note: The PPA15xx includes the following modes via sub menu: POWER INTEGRATOR, PHASE METER, IMPEDANCE METER ® START, STOP, ZERO AND TRIGGER Trigger button refreshes measurement, Zero resets datalog or allows an offset trim Start and Stop buttons provide manual control of a measurement...

 Open the catalog to page 2
Compact Power Analyzers PPA500Series, PPA1500Series-3

Example Applications Example Application : Standby Power Measurement IEC62301/EN50564 The PPA5xx and PPA15xx are the perfect instruments for tests such as EN50564 Standby Power Testing. PC software that provides simple testing and reporting for EN50564 is available from the N4L website. Clear, Flexible Display Backlit LED display with zoom functions to customise instrument configurations can be saved to internal memory, an external USB device or directly into N4L software. Meets or exceeds the requirements and methodology of U.S. EPA (Energy Star), U.S.DOE, California Energy Commission (CEC),...

 Open the catalog to page 3
Compact Power Analyzers PPA500Series, PPA1500Series-4

High Performance Voltage Attenuating Probes

 Open the catalog to page 4
Compact Power Analyzers PPA500Series, PPA1500Series-6

Newtons4th are an accredited UKAS Calibration laboratory, all PPA500 and PPA1500 Power Analyzers are supplied with an ISO17025 UKAS Calibration Certifcate as standard. Calibration of N4L Power Analyzers is an integral and important part of our service to our clients, we offer quick turnaround times at a competitive price. Re-Calibration is also available at our international offices and various distributors throughout the world1. N4L's schedule of accreditation to ISO17025 is wide ranging and an overview of the schedule is detailed below, for more specific information please see the UKAS website...

 Open the catalog to page 6
Compact Power Analyzers PPA500Series, PPA1500Series-7

Voltage Input Phase Accuracy As per standard spec with Rng error reduced from +0.1% A Rng to 0.05% As per standard spec with Rng error reduced from +0.1% A Rng to 0.05% Power Accuracy As per standard spec with Rng error reduced from +0.1% VA Rng to 0.05% Minimum Current Measurement at Full Accuracy Crest Factor Sample Rate Application Modes As per standard spec with Rng error reduced from +0.1% VA Rng to 0.05% Ballast, Inrush, Standby Power CMRR - Common Mode Rejection Ratio Measurement Parameters Ballast, Inrush, Standby Power 100V @ 100kHz - > 3mA (130dB) W, VA, Var, pf, V & A - rms, rectified...

 Open the catalog to page 7
Compact Power Analyzers PPA500Series, PPA1500Series-8

All specifications at 23°C ± 5°C . These specifications are quoted in good faith but Newtons4th Ltd reserves the right to amend any specification at any time without notice The N4L product range also includes Frequency Response and Impedance Analyzers, Selective Level Meters and Laboratory Power Amplifiers Applications • Power supply phase margin and gain margin (FRA) • Inductance, Capacitance and Resistance (LCR) • Analysis of mechanical vibration (HARM) • Phase Angle Voltmeter (PAV) Contact your local N4L Distributor for further details Newtons4th Newtons4th Ltd (abbreviated to N4L) was established...

 Open the catalog to page 8
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.