SEMICONDUCTOR GAS DETECTOR PS-8 SERIES *1 Request separately piping In Inches. *2 Recommended tube length less than 20m. For gases with strong adhesion like Halogen, recommend piping of 5m or less. In areas with high dust levels It may be necessary to shorten and periodically replace piping mote than the recommendation. *3 Modbus-RTU can be used with Ethernet or dispersion unit *40utput accuracy; within FS ± 05%. The Main Unit analog output Is limited to the Main Unit The Sub Unit sensor analog output requires the AO expansion module. The AO expansion module can output analog signals from the Main Unit allowing for multiple connections. *5 When installing two or more sensors using a Sub Unit and using Individual contact output use a DO expansion module. In this case, the Individual outputs for the sensors Installed In the Main Unit will be outputfrom the expansion unit (the main unit’s contacts will be output all at once). *6 When using both analog and digital output power consumption inaeaies dramatically. *7 Power consumption when using the maximum number of modules. The above Information may be subject to change without notice NEW COSMOS GLGCTRIC CO..LTD. Offices_ Group Companies_ Head Office (Osaka, Japan) 2-5-4 Mitsuyana ka, Yodogawa-ku, Osaka, Japan 5320036 Phone: +81 -6-6885-8484 E-mail: [email protected] Thailand Office 4345 Bhiraj Tower at BITEC, 23rd Floor, Sukhumvit Rd„ South Bangna, Bangna, Bangkok 10260Thailand Phone: +66-2-017-5175 E-mail: [email protected] Paris Office 128 Rue Du Faubourg Salnt-Honore, 75008 Paris, France Phone: +33 6-62-93-51-53 E-mail: [email protected] NEW COSMOS ELECTRIC (SHANGHAI) CO., LTD. 4th Plant No.385, Dongxing Road, Songjlang Industrial Zone, Shanghal,Chlna2016l3 Phone: +86-21 -6774-3138 E-mail: [email protected] NEW COSMOS ELECTRIC KOREA CO., LTD. 3R4F BMYTower, 16, Teheran-ro 27-gil, Gangnam-gu, Seoul, Korea Phone:+82-2-555-3102 E-mail: [email protected] TAIWAN NEW COSMOS ELECTRIC CO.,LTD 10F.-3, No. 93, Shulyuan St, East Dlst, Hslnchu City 300042, Taiwan Phone: +886-3-574-4593 E-mail: cosmostl ems75.hlnet.net 650Warrenvllle Road, Suite 101, Lisle, IL60532, USA E-mail: [email protected] New Cosmos-BIE (Netherlands) Maxwellstraat 7, NL-1704 SG, Heerhugowaard, the Netherlands Phone: +31 -72-576-5630 E-mail: [email protected] Developed with the highest level of technical precision 1. Customizable Target Gas2. Compatible with our pyrolyzer-integrated NF3 and COS sensors.3. Easy visual verification \ using large LCD screen / SAFETYWARNING Carefully read the instruction manual prior to use. Select and use the device designed to detect the required type of gas. Use of a wrong sensor type may cause an accident.
Open the catalog to page 1SEMICONDUCTOR GAS DETECTOR PS-8 SERIES Target gas may be tailored to user specifications. For technical assistance, we provide global engineering and service support for your needs. *Please inquire for other gas types I One main unit can display sensor information from up to 12 nodes Sensors can be set to match user needs based on the type of gas and concentration level Max 4 Expansion Units attached to the Main Unit ISfflffffr A smarter pyrolyzer-integrated system The NF3 and COS sensors designed for the PS-8 series come equipped with integrated pyrolyzers, which eliminates the necessity for...
Open the catalog to page 22 Pages
2 Pages
2 Pages
2 Pages
2 Pages
1 Page
1 Page
1 Page
1 Page
4 Pages
1 Page
16 Pages
32 Pages
8 Pages
2 Pages
4 Pages
2 Pages
2 Pages
1 Page