SEMICONDUCTOR GAS DETECTOR PS-8 SERIES *1 Request separately piping in indies. *2 For gases with strong adhesion like Flalogen, recommend piping of 5m or less. In areas with high dust levels it may be necessary to shorten and periodically replace piping more than the recommendation. *3 Modbus-RTU can be used with Ethernet or dispersion unit. *4 The Main Unit analog output is limited to the Main Unit. The Sub Unit sensor analog output requires the AO expansion module. The AO expansion module can output analog signals from the Main Unit allowing for multiple connections. *5 When installing two or more sensors using a Sub Unit and using individual contact output, use a DO expansion module. In this case, the individual outputs for the sensors installed in the Main Unit will be outputfrom the expansion unit (the main unit's contacts will be output all at once). *6 When using both analog and digital output power consumption Increases dramatically. *7 Power consumption when using the maximum number of modules. The above information may be subject to change without notice. Developed with the highest level of technical prowess Features N€W COSMOS GLGCTRIC CO , LTD. Offices_Head Office (Osaka, Japan) 2-5-4 Mitsuyanaka, Yodogawa-ku, Osaka, Japan 5320036 Phone: +81-6-6885-8484 E-mail: e-info0new-cosmos.co.jp Thailand Office 4345 Bhiraj Tower at BITEC, 23rd Floor, Sukhumvit Rd„ South Bangna, Bangna, Bangkok 10260 Thailand Phone:+66-2-017-5175 E-mail: info.cosmos1hailand0new-cosmos.co.th Paris Office 128 Rue Du Faubourg Saint-Honore, 75008 Paris, France Phone: +33 6-62-93-51-53 E-mail: info0new-cosmos.fr Group Companies NEW COSMOS ELECTRIC (SHANGHAI) CO., LTD. 4th Plant No.385, Dongxing Road, Songjiang Industrial Zone, Shanghai,China 201613 Phone: +86-21-6774-3138 E-mail: info0new-cosmos.com.cn 3F,4F BMY Tower, 16, Teheran-ro 27-gil, Gangnam-gu, Seoul, Korea Phone: +82-2-555-3102 E-mail: info0new-cosmos.co.kr TAIWAN NEW COSMOS ELECTRIC CO.,LTD 10F.-3, No. 93, Shuiyuan St., East Dist., Hsinchu City 300042, Taiwan Phone: +886-3-574-4593 E-mail: cosmost1@ms75.hinet.net New Cosmos USA, Inc. 650 Wartenville Road, Suite 101, Lisle, IL 60532, USA Maxwellstraat 7, NL-1704 SG, Heerhugowaard, the Netherlands Phone: +31-72-576-5630 E-mail: sales0newcosmos-europe.com 2. Integrated thermal decomposition converter 3. Easy visual verification using large LCD screen SAFETY WARNING Carefully read the instruction manual prior to use. Select and use the device designed to detect the required type of gas. Use of a wrong sensor type may cause an accident.
Open the catalog to page 1
SEMICONDUCTOR GAS DETECTOR PS-8 SERIES *Please inquire for other gas types I One main unit can display sensor information from up to 16 nodes. Sensors can be set to match user needs based on the type of gas and concentration level Integrated thermal decomposition converter Bulky external converter no longer necessary BBIWIE Confirm concentration levels at a glance with the large LCD screen Tag name Gas type - Expansion Unit 2 expansion units attached to the Main Unit Module Line-up • AO Module (Analog Output) • DO Module (Contact Output) • Al Module (Analog Output) Check sensor records up...
Open the catalog to page 2All New Cosmos catalogs and technical brochures
-
SDM 72 / SDM-73
2 Pages
-
ePACT controller
2 Pages
-
Brochure XP-3000II
2 Pages
-
KS-7R
2 Pages
-
SH-4004-WAD
1 Pages
-
SH-4002-WAD
1 Pages
-
SH-4001-WAD
1 Pages
-
SH-1003/1007-WAD
1 Pages
-
KD-12A
4 Pages
-
SDM-72/73
1 Pages
-
Portable Gas Detection
16 Pages
-
Gas Detection and Alarm Systems
32 Pages
-
Portable detection
8 Pages
-
New Energy
2 Pages
-
Semiconductor
4 Pages
-
Gas and oil leaflet
2 Pages
-
Automotive Leaflet
2 Pages
Archived catalogs
-
PS-7
1 Pages