1. Catalogs
  2. New Cosmos
  3. Portable detection

Portable detection

Portable detection

Portable detection

Product catalog summary
Introduction: This document serves as a comprehensive guide on portable gas detectors by New Cosmos Electric Co., Ltd., detailing specifications, features, and applications for detecting combustible gases and oxygen levels.
Safety Warning: Users must read the operating instructions thoroughly and select the correct sensor type for the specific gas to prevent accidents.
Product Specifications:
  • XP-3110: Utilizes a catalytic combustion sensor for detecting combustible gases with a range of 0-100% LEL and an accuracy of ±5% full scale. It includes a digital display and alarm systems.
  • XP-3140: Detects gases like methane and propane using thermal conductivity, with a range of 0-100 vol% and digital display with alarms.
  • XP-3118 and XP-3160: High sensitivity detection for combustible gases and oxygen, with ranges up to 10,000 ppm, featuring built-in correction factors and powerful pumps.
Applications: Suitable for leak inspections, environmental monitoring, and VOC measurement in industries such as construction, chemistry, and automotive.
Additional Features: Highlights include compact design, extended battery life, and compliance with safety standards. Optional accessories include gas sampling hoses and data download software.
Conclusion: New Cosmos Electric's portable gas detectors provide reliable solutions for monitoring gas concentrations, ensuring safety and compliance with industry standards.
Device Specifications:
  • XP-3180E: Detects oxygen in flue gas using a galvanic cell with a range of 0-25.0vol% and an accuracy of ±0.3vol%.
  • XOS-2200: Measures oxygen with a range of 0-25vol% using a galvanic cell and diffusion sampling method.
  • XOC-2200: Detects oxygen and carbon monoxide with ranges of 0-25vol% and 0-300ppm, respectively.
  • XP-308B: Detects formaldehyde with a range of 0.01 to 0.38mg/m3 using an electrochemical cell.
  • SDM-72: Measures steel dust concentration in grease with a range of 0-5.000%wt.
  • XP-704 III: Detects refrigerant gases with a response time within 10 seconds.
Key Features and Considerations:
  • Devices include various alarm modes such as buzzers, flashing lights, and vibrators.
  • Battery life varies, with some devices offering up to 5000 hours of operation.
  • Operating conditions like temperature and humidity are specified for accuracy.
  • Standard accessories include batteries, sampling hoses, and carrying cases.
  • Users should avoid tobacco smoke and alcohols during measurement and be aware of environmental changes affecting detection accuracy.
See more

Catalog excerpts

Portable detection-1

OVERSEAS NETWORK PORTABLE GAS DETECTORS PRODUCT GUIDE New Cosmos Electric Co., Ltd. (Korea Office) New Cosmos Electric (Shanghai) Co., Ltd. New Cosmos Electric Co., Ltd. Overseas Business Division New Cosmos Electric Co., Ltd. Head Quarters New Cosmos Electric Co., Ltd. (Taiwan Office) SAFETY WARNING Head Quarters 2-5-4 Mitsuya-naka, Yodogawa-ku, Osaka 532-0036 JAPAN Overseas Business Division Read the operating instructions thoroughly before use. Always operate in accordance with the instructions. Be sure to choose the sensor designed to detect the required type of gas. Use of the wrong sensor type could cause an accident. 2-6-2 Hamamatsu-cho, Minato-ku, Tokyo 105-0013 JAPAN PHONE: +81-3-5403-2715 FAX: +81-3-5403-2710 Email: [email protected] www.new-cosmos.co.jp/en/ New Cosmos BIE (B.V.) maxwellstraat 7, NL-1704 SG, Heerhugowaard, The Netherlands PHONE: +31-72-576 5630 FAX: +31-72 572 1818 Email: [email protected] www.newcosmos-europe.com New Cosmos Electric (Shanghai) Co., Ltd. PHONE: +86-21-6774-3138 FAX: 86-21-6774-3138 Email: [email protected] New Cosmos Electric Co., Ltd. (Korea Office) PHONE: +70-8615-2715 FAX: +70-8612-2716 Email: [email protected] www.new-cosmos.co.jp/kr New Cosmos Electric Co., Ltd. (Taiwan Office) PHONE: +3-574-4593 FAX: +3-574-4593 Email: [email protected] Printed in Japan 201512.2K-02

 Open the catalog to page 1
Portable detection-2

COMBUSTIBLE GAS DETECTORS PORTABLE GAS DETECTOR XP-3110Please make your specification by filling in the type of a gas. Catalytic combustion sensor FEATURES For measurement of combustible gas concentration of 0-10/0-100%LEL. Suitable for monitoring a risk of explosion. New digital display with a simulated analog scale. Built-in correction factors for up to 5 flammable gases.(factory option) Ex: Methane, Isobutane, Propane, Ethanol, Hydrogen, Acetylene, etc. SPECIFICATIONS Model Gas Detected XP-3140Please make your specification by filling in the type of a gas. COMBUSTIBLE GAS DETECTOR XP-3160Please...

 Open the catalog to page 2
Portable detection-3

COMBUSTIBLE GAS DETECTORS GAS LEAK DETECTOR XP-702III FEATURES Smaller and Lighter Easy-to-See LCD Display Two Alarm Lamps Trace Gas can be Detected Capable of Detecting 2-Gas Hot wire semiconductor sensor USAGE EXAMPLES Inspection for leaks from gas pipes Indoor piping, gas outlets, rubber tubes SPECIFICATIONS Model XP-702III-A XP-702III-B XP-702III-F 2 combustible gas 1 combustible gas CFC & Combustible gas (switchable) (switchable) Detection Principle Hot-wire semiconductor Town gas, LPG, etc.: 3.3 × 10-6Pa.m3/s Detectable Leak Rate CFCs: [R407C] 12.4g/year [R410A] 11.2g/year Detectable 10...

 Open the catalog to page 3
Portable detection-4

OXYGEN INDICATORS PERSONAL OXYGEN INDICATOR OXYGEN INDICATORS Galvanic cell sensor DIGITAL OXYGEN INDICATOR Galvanic cell sensor FEATURES Can be used continuously for 5000 hours. Available with loud buzzer, alarm lamp from 4 dimensions, peak hold function. Thin, lightweight design. SPECIFICATIONS Model Gas Detected Detection Principle Sampling Method Detection Range (Service Range) Resolution Indication Accuracy *1 Alarm Set Value 1st stage 2nd stage Response Time *2 Display Mode Alarm Mode Functions (Actual size) Operation Temperature Operation Air Pressure Power Source Battery Life *3 Dimensions...

 Open the catalog to page 4
Portable detection-5

TOXIC GAS DETECTORS PERSONAL CO DETECTOR Electrochemical cell sensor Electrochemical cell sensor FEATURES Can be used continuously for 5,000 hours. Available with loud buzzer, alarm lamp from 4 dimensions, peak hold function. Available with TWA (Time Weighted Average) gas concentration display, memory of peak value, and peak hold function. Thin, lightweight design. How to replace the sensor unit SPECIFICATIONS Model Gas Detected Detection Principle Sampling Method Measuring Range (Service Range) Resolution Indication Accuracy *1 Alarm Set Value Response Time *2 Display Mode Alarm Mode Functions...

 Open the catalog to page 5
Portable detection-6

MULTI-GAS DETECTORS COMBUSTIBLE GAS DETECTOR GAS LEAK DETECTOR Hot wire semiconductor sensor MULTI-GAS DETECTOR Infrared Port Catalytic combustion sensor Galvanic cell sensor Electrochemical cell sensor Water and Dust Proof (IP67) Can detect trace amounts of various semiconductor manufacturing gases. Automatic stop pump function Automatic gas exhaust mode Equivalent to IP22 (in soft case) SPECIFICATIONS Model Target Gas Detection Principle Sampling Method Detectable Leak Rate Detectable Gas Concentration Response Time Power Supply Within 10 seconds (for 300% of detectable gas concentration) Size...

 Open the catalog to page 6
Portable detection-7

MULTI-GAS DETECTORS PERSONAL CO/O2 DETECTOR ODOR LEVEL INDICATOR Electrochemical cell sensor ODOR LEVEL INDICATOR Simple measurement of odor level. Uses continuously for 5,000 hours. 3 types of Alarms: loud buzzer, alarm lamp and vibration. Available with TWA (Time Weighted Average) concentration display, peak memory, and peak hold function. APPLICATIONS Performance check of air purifier and deodorization equipment. Odor measurement of factory exhausts. Quality control of foods and spices. SPECIFICATIONS Model Gas Detected Detection Principle Sampling Method Measuring Range (Service Range) Resolution...

 Open the catalog to page 7
Portable detection-8

INDOOR AIR POLLUTANT DETECTOR FORMALDEHYDE DETECTOR Electrochemical cell sensor GREASE STEEL DUST METER No need to replace reagents for each measurement. Possible to change mg/m³ and ppm as measurement unit. Possible to change 10 min, 30 min and 60 min as measurement time. Fully automatic operation simply by pushing operation buttons. Max. 32 cases of measuring result can be memorized. Reduced influence of VOCs with DNPH filter. Enable the wear condition of bearings to be simply determined before vibration increases. Simple operation - simply measured by a grease sample. Simple diagnosis and...

 Open the catalog to page 8
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.