MED PZR
2Pages

{{requestButtons}}

Catalog excerpts

MED PZR - 1

FILTRATION MED PZR APPLICATION OF NEGATIVE PRESSURE TO THE PRESSURISER * available in IODAIR version - independent from MED CP - for site with iodine risk To protect operators and their environment + Mobile ventilation unit intended to apply negative pressure to the pressuriser. It can be controlled by the MED CP (negative pressure applied to the primary circuit) + Specifically designed to comply with DT 288 (the edf framework and Technical Directive) + Coated in decontaminable paint + Equipped with : • THE polydiedre filter • Iodine trap with activated carbon • Heating battery • Control and safety systems. OPERATING PRINCIPLE + Air is sucked in via a flexible duct (0 300 mm) equipped with quick-fit connectors. + The air passes through a « nuclear » absolute filter, an electric heater coil in order not to exceed 40 % relative humidity in the air and then an active charcoal filter to trap radioactive iodine. + Negative pressure is applied to the whole assemble by a UNILINE® fan. + The discharge can be equipped with a 0 300 quick fit connector to allow a flexible duct to be connected.. + Replacement of the absolute filter is performed in a vinyl bag to avoid spreading any contamination during this procedure. MED PZR IS EQUIPPED WITH THE FOLLOWING AS STANDARD : + An electrical control and power cabinet + Built-in filter blocked pressure switch (continuous pressure loss detection and configurable set-point value) + 2 limit switches for the absolute filter and iodine filter. If the filter is incorrectly positioned, the absence of contact prohib its the starting of the differential pressure device. A defect indicator is associated with this contact. + Automatic fan re-start in the event of power failure + 4,5 kW heating battery + A RS485 connection is available for the radioprotection station The manufacturer formally reserves the right to make any modifications it considers suitable to its models.

Open the catalog to page 1
MED PZR - 2

Maxi flow rate of the fan at nominal flow rate Empty weight Heater power Available pressure Absolute filter (*) (filtering surface : 20,5 m2) Nuclear-certified absolute Filter pressure drop filter 250 Pa clean filter 610 x 305 292 mm 800 Pa clogged filter (recommanded value) Iodine filter (**) Nuclear-certified iodine filter 610 x 610 x 292 mm (*) Absolute filter : DOP and Nacl > 99,99 % - URANINE cleaning coefficient > 5 000 (**) Iodine filter : cleaning coefficient 4 000 with lCH3 Parc d’activités de la Houssoye – Rue Ampère – 59930 La Chapelle d’Armentières - France Tél. +33 (0)3 20 10...

Open the catalog to page 2

All NEU-JKF catalogs and technical brochures

  1. JETLINE® CH

    2 Pages

  2. HDP

    2 Pages

  3. TEST URANINE

    2 Pages

  4. JETLINE® KS

    2 Pages

  5. IODAIR® 600

    2 Pages

  6. IODAIR®

    2 Pages

  7. SEPAROPACK R

    2 Pages

  8. ACHD

    2 Pages

  9. AQUALINE®

    2 Pages

  10. B.O.A.

    2 Pages

  11. Chopperline

    2 Pages

  12. CYCLAIR®

    2 Pages

  13. DELTOLE

    2 Pages

  14. JETLINE® E

    2 Pages

  15. JETLINE® K

    2 Pages

  16. MED CP

    2 Pages

  17. MED GV

    2 Pages

  18. OILPACK

    2 Pages

  19. SEPAROJET®P

    2 Pages

  20. SEPAROPACK C

    2 Pages

  21. SEPAROPACK V

    2 Pages

  22. DELTAJET® S

    2 Pages