Application of Negative Pressure to the Primary Circuit
The MED CP system is designed to protect operators and the environment during the valve control phase by applying negative pressure to the primary circuit. It functions as a 'Lower Generator' to automatically implement standardized air speeds, which are configurable and continuously controlled. This reduces radiological risk by preventing atmospheric contamination of the reactor building.

Operating Principle
The system operates by filtering suctioned air through two 'nuclear' absolute filters. The air is then heated and passed through a second filtration stage to trap radioactive iodine. The cleaned air can be released into the reactor building or the EBA system. A RS485 connection is available for the radioprotection station.

Advantages
  • Enhances safety by strengthening lines of defense.
  • Facilitates worry-free servicing and simplifies on-site activities due to ease of use.
  • Ensures availability by controlling the reactor shutdown schedule.
  • Improves security with automatic reset, preventing spurious shutdowns of differential pressure devices.
  • Installation and removal of the MED CP have no impact on the reactor shutdown schedule, taking approximately 3 hours each.
  • Reduces waste and contamination, leading to fewer site evacuations and financial savings.

Characteristics
  • Flow rate: 200 to 4,800 m3/h.
  • Filtration: 2 absolute filters and 4 iodine filters.
  • Safety: MED PZR/MED CP slaving with a connector for a CYCLAIR® unit as backup.
  • Measurements: Anemometric probes and 2 temperature and relative humidity probes.
  • Flow rate adjustment: Controlled by PLC-controlled speed variators.
See more

Catalog excerpts

MED CP-1

MED CPAPPLICATION OF NEGATIVE PRESSURE TO THE PRIMARY CIRCUIT + As a “Lower Generator”, the MED CP applies negative pressure to the primary circuit. + It allows the automatic implementation of standardised air speeds. These air speeds are configurable and continuously controlled. + Reduced radiological risk (individual and collective dose rate) - no atmospheric contamination of the reactor building OPERATING PRINCIPLE + The suctioned air is filtered by two "nuclear" absolute filters. + This air is then heated before passing through the second filtration stage to trap the radioactive iodine. + The cleaned air can be released in the reactor building or the E BA system. + A RS485 connection is available for the radioprotection station ADVANTAGES + Safety (strengthening the lines of defence) + Worry-free servicing + Simplification of activities on site : the MED CP is easy to use + Availability (control of the reactor shutdown schedule) + Security (no more spurious shutting down of the differential pressure devices) - automatic reset + Installation of the MED CP has no impact on the reactor shutdown schedule (MED CP deployment: 3 hours; likewise to remove it from the reactor building) + Reduced waste (fewer airlocks, etc.) + Financial savings: less contamination in the reactor building = fewer site evacuations The manufacturer formally reserves the right to make any modifications it considers suitable to its models.

 Open the catalog to page 1
MED CP-2

Parc d'activites de la Houssoye - Rue Ampere - 59930 La Chapelle d'Armentieres - France Tel. +33 (0)3 20 10 53 66 • Contact : [email protected]

 Open the catalog to page 2

All NEU-JKF catalogs and technical brochures

  1. HDP

    2  Pages

  2. TEST URANINE

    2  Pages

  3. JETLINE® KS

    2  Pages

  4. IODAIR® 600

    2  Pages

  5. IODAIR®

    2  Pages

  6. SEPAROPACK R

    2  Pages

  7. ACHD

    2  Pages

  8. AQUALINE®

    2  Pages

  9. B.O.A.

    2  Pages

  10. Chopperline

    2  Pages

  11. CYCLAIR®

    2  Pages

  12. DELTOLE

    2  Pages

  13. FILTRACLEAN S

    2  Pages

  14. JETLINE® E

    2  Pages

  15. JETLINE® K

    2  Pages

  16. MED GV

    2  Pages

  17. MED PZR

    2  Pages

  18. NEUMATIC® JK

    2  Pages

  19. OILPACK

    2  Pages

  20. SEPAROJET®P

    2  Pages

  21. SEPAROPACK C

    2  Pages

  22. SEPAROPACK V

    2  Pages

  23. DELTAJET® S

    2  Pages

  24. CYCLAIR 300®

    2  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.