Group: NEU-JKF
Catalog excerpts
When the alarm is active: • The green "pressure OK" LED on the front panel is off. • The red "alarm" LED on the front panel lights up. • The siren is activated • The strobe light is activated • The differential pressure measurement flashes. AIRLOCK PRESSURE CONTROLLER DIFFERENTIAL PRESSURE MEASUREMENTThe AIRLOCK PRESSURE CONTROLLER is a differential pressure measurement device. • The measurement is read from a three-digit LED-type display. • The pressure is compared to an alarm threshold value. If the pressure is below the threshold value, the alarm is triggered. The alarm status is indicated by LEDs on the front panel and transmitted by a relay. • The casing is equipped with a siren/strobe light which is activated when the alarm is triggered. • The alarm threshold value can be adjusted by the user by means of the buttons and the display on the front of the casing. • Access to the alarm threshold value is authorized following correct entry of a protection code. • This device is designed for installation in nuclear power plants. The manufacturer formally reserves the right to make any modifications it considers suitable to its models. If the measured differential pressure remains below the set alarm threshold value for more than 10 seconds, the alarm will be triggered. If the measured differential pressure then rises above the set alarm threshold value for more than 10 seconds, the alarm will be cancelled. When the alarm is not active: • The green "pressure OK" LED on the front panel is on. • The red "alarm" LED on the front panel is off. • The siren is not activated • The strobe light is not activated • A steady differential pressure measurement is displayed. The "TEST" button on the front panel is used to test the alarm. If the button is pressed: • The green "pressure OK" LED on the front panel goes off. • The red "alarm" LED on the front panel lights up. The siren is activated • The strobe light is activated • A steady differential pressure measurement is displayed.
Open the catalog to page 1CASING • Supply voltage (rated voltage) • Operating temperature • Storage temperature • Electronic board protection • Casing power supply protection DP MEASUREMENT • Scale • Max. pressure (P+>P-) • Humidity of measurable fluids (non-condensing) • Measurable fluids • Type of materials in contact with fluid • Alarm response time • Alarm threshold setting SIREN • Type • Acoustic power • Luminous intensity 230 V AC 50 Hz maximum power 50 mA typical 800 mA max. (when switched on) 0° to 60°C -20° to 70°C ABS material 240x191x107 IP65 / IK07 (except siren) Cover with hinges...
Open the catalog to page 2All NEU-JKF catalogs and technical brochures
-
JETLINE® CH
2 Pages
-
NEUMATIC® JE / JR
2 Pages
-
Corporate Brochure
2 Pages
-
Flyer NEU-JKF Fevi_EN
2 Pages
-
NEU CLEAN UNLOADING STATION®
2 Pages
-
Vanne d'aiguillage AMCR
2 Pages
-
Écluse rotative PV
2 Pages
-
HDP
2 Pages
-
JETLINE® E HD
2 Pages
-
JETLINE ® K Compact
2 Pages
-
TEST URANINE
2 Pages
-
PUPITRE SHELTER
2 Pages
-
EXTRACTAIR® C
2 Pages
-
JETLINE® KS
2 Pages
-
IODAIR® 600
2 Pages
-
IODAIR®
2 Pages
-
ÉCLUSE POUSSIÈRES
2 Pages
-
DEM DUST EMISSION CONTROL
2 Pages
-
Manches - Nucléaire
2 Pages
-
SEPAROPACK R
2 Pages
-
FILTRACLEAN® ECO
2 Pages
-
ACHD
2 Pages
-
JETLINE® V / VR
2 Pages
-
POLUCLEAN® SI
2 Pages
-
AQUALINE®
2 Pages
-
B.O.A.
2 Pages
-
Chopperline
2 Pages
-
CYCLAIR®
2 Pages
-
DELTOLE
2 Pages
-
FILTRACLEAN S
2 Pages
-
JETLINE® E
2 Pages
-
JETLINE® K
2 Pages
-
MED CP
2 Pages
-
MED GV
2 Pages
-
MED PZR
2 Pages
-
NEUMATIC® JK
2 Pages
-
OILPACK
2 Pages
-
SEPAROJET®P
2 Pages
-
SEPAROPACK C
2 Pages
-
SEPAROPACK V
2 Pages
-
COBRA® SERIES
4 Pages
-
ECONOCLIM® B / C
1 Pages
-
DELTAJET® S
2 Pages
-
CYCLAIR 300®
2 Pages
-
SEPAROBOIS® M / P
2 Pages