Product Overview
12Pages

{{requestButtons}}

Catalog excerpts

Product Overview - 1

Product Overview Thermal Analysis, Thermophysical Properties Testing, Cure Monitoring, Rheology, Accelerating Rate and Isothermal Calorimetry, Fire Testing and HotBox Test Chambers Analyzing & Testing

Open the catalog to page 1
Product Overview - 2

Differential Scanning Calorimetry (DSC) Differential Thermal Analysis (DTA) -180°C to 2000°C The various types of NETZSCH DSC instruments all operate in accordance with the heat flow principle. They are characterized by a three-dimensional symmetrical design with homogeneous heating. Sensors with high calorimetric sensitivity, short time constants and a condensation-free sample chamber in the DSC cell ensure high detection sensitivity. Thermogravimetric Analysis (TGA) 10°C to 1100°C NETZSCH TGA instruments are equipped with digital balances and are vertically designed, featuring a...

Open the catalog to page 2
Product Overview - 3

ANALYSIS Dilatometry (DIL)/Thermomechanical Analysis (TMA) -180°C to 2800°C/-150°C to 1550°C Dimensional changes of the specimen as a function of temperature under a defined load can be monitored with the DIL 402 Expedis series of pushrod dilatometers. Interchangeable furnaces cover all applications for high-precision expansion control in development, basic research and quality control in a very wide temperature range. The TMA 402 F1/ F3 Hyperion® series is determining the dimensional changes in solids, liquids or pasty materials as a function of temperature and/or time under a defined...

Open the catalog to page 3
Product Overview - 4

Calorimetry (ARC/MMC) RT to 500°C The Multiple-Module Calorimeter MMC 274 Nexus® measures chemical reactions and phase changes on gram-size samples for the investigation of process safety, thermal runaway reactions (Heat-WaitSearch), coin cells, etc. Additionally, the well proven Accelerating Rate Calorimeters ARC 244/254 with the patented VariPhi® technology, are high-end systems investigating data relevant to processing and storage of chemicals, chemical process safety and the evaluation of thermal and pressure hazard. Evolved Gas Analysis (EGA) Coupled to Thermal Analysis By coupling a...

Open the catalog to page 4
Product Overview - 5

Refractory Testing by RUL and HMOR RT to 1700°C Special strength-testing methods have been established for refractory ceramics. The RUL 421, Refractoriness under Load (RUL) and Creep in Compression (CIC), identifies the deformation resistance of a test piece under a defined load at a specified temperature/time program. The Hot Modulus of Rupture (HMOR 422) at high temperatures is determined as the amount of force applied to a rectangular test piece at high temperatures until failure occurs. Laser/Light Flash Analysis (LFA) Time Domain Thermoreflectance (TDTR) – LFA for Thin Films -125°C to...

Open the catalog to page 5
Product Overview - 6

Simultaneous Determination of Seebeck Coefficient and Electrical Conductivity -125°C to 1100°C One approach in the field of thermoelectricity is to generate electrical energy from released heat. The SBA 458 Nemesis® can accompany the development of thermoelectric materials with high working temperatures and optimized efficiency. It allows for the simultaneous measurement of the Seebeck coefficient and electrical conductivity under identical conditions. Thermal Conductivity by Heat Flow Meter (HFM) and Guarded Hot Plate (GHP) -160°C to 600°C Our HFM 446 Lambda Eco-Line measures the thermal...

Open the catalog to page 6
Product Overview - 7

RHEOLOGY Rheological properties can be tested for all materials from fluids such as dilute solutions of polymers and surfactants through to concentrated protein formulations, to semi-solids such as pastes and creams, to molten or solid polymers as well as asphalt binders. Kinexus Series Kinexus rotational rheometer platform has been developed from extensive market feedback. The integrated innovative instrument design includes a revolutionary software interface. In a broad temperature range between -40°C to 350°C, a wide torque range from 0.5 nNm to 240 nNm is available. The Kinexus series...

Open the catalog to page 7
Product Overview - 8

Advanced Software Kinetics Neo and Kinetics as a Service The kinetic analysis of thermal measurements allows finding the set of kinetic parameters, e.g., number of steps, contribution of each step to the total effect of the process such as step enthalpy or stepping mass loss; reaction type, activation energy and reaction order for each step. Then this information will be used for predictions of reaction progress for given temperature conditions or optimization of temperatures to get the desired reaction rate and product concentrations. With Kinetics as a Service, NETZSCH offers a...

Open the catalog to page 8
Product Overview - 9

Products Proteus® Protect Proteus® Protect ensures data integrity at the highest level and meets the requirements of 21 CFR Part 11 or EU Annex 11. Super-Res® (RCM, RCS) This software feature offers rate-controlled temperature management (mass-change-controlled TGA, i.e., RCM; and shrinkage-rate-controlled dilatometry, i.e., RCS) is well suited for increasing the resolution of superimposed effects and enhancing sample compaction for sintering processes. Purity Determination For crystalline substances with known molar mass, Purity Determination serves to determine the percentage of eutectic...

Open the catalog to page 9
Product Overview - 10

Hotbox Test Chambers The HotBox Systems are constructively complex test devices for determining the heat transfer properties of wall elements, walls, windows and doors. In the HotBox, it is possible to simulate real-world conditions as they would exist for a building wall, by simulating conditions both inside the building and on the outside of the wall. The HotBox takes into consideration not only the heat conduction through the test specimen (pure material dependence), but also the heat transfer conditions (material properties and ambient conditions). Our test chambers for determining the...

Open the catalog to page 10
Product Overview - 11

Heat release Smoke development Flame spread Flaming droplet TRDA/ TRDL Burning time/speed Mass loss Oxygen index O2, CO2, CO analyzer Euro classification/ Euro fire testing lab TRDA – Smoke Density Tester with light measurement system Mostly integrated Building, ElectroAutonics, motive, Polymers Polymers Polymers Single/ Standalone ISO 3795, DIN 75200, ISO MVSS 302, ISO UL94, 4589-2, GB 8410, 5660-1, DIN EN DIN IS 15061, DIN ASTM 60695-11, 22117, CMVSS 50055 E 1354 ISO 9773 ASTM 302, D 2863 U.T.A.C. 18-502, FAR 25.853 LOI 901 – Oxygen Index Analyzer DIN CEN/TS 1187, test procedure 4

Open the catalog to page 11

All NETZSCH Analyzing & Testing catalogs and technical brochures

  1. HMOR 422

    1 Pages

  2. RUL/CIC 421

    1 Pages

  3. Rosand Series

    20 Pages

  4. NTA HotBoxes

    16 Pages

  5. Kinetics NEO

    16 Pages

  6. DEA 288 Ionic

    20 Pages

  7. GABOMETER®

    8 Pages