Kinexus Prime DSR Series Redefining Rheometer Capabilities for Asphalt Binder and Bitumen Testing Analyzing & Testing

Open the catalog to page 1
Kinexus Prime DSR Series - 2

Characterization and Classification to Asphalt Industry Asphalt Binder and Bitumen

Open the catalog to page 2
Kinexus Prime DSR Series - 3

Asphalt, or bitumen, is a petroleum product used in the road (pavement), roofing and construction industries. A mixture of aromatic hydrocarbons (varying with geographical source), this black viscoelastic material is considered to be a complex colloidal system. Asphalt is used as a binder with aggregates in road (pavement) construction and as such determines performance and lifetime. Additives such as polymers, crumb rubber, oils, waxes, phosphates and pH adjusters are used to enhance mechanical properties in modified asphalt binders. Asphalt emulsions are also used as water-proofing and...

Open the catalog to page 3
Kinexus Prime DSR Series - 4

Kinexus Prime DSR Series Redefining Rheometer Capabilities for Asphalt Binder and Bitumen Testing The Kinexus Prime DSR Series is the next generation rotational rheometer platform for asphalt testing that’s been developed from extensive market knowledge and feedback, integrating innovative instrument design with a revolutionary software interface, to deliver an intelligent solution that will exceed your rheological expectations. A modular rheometer with true plug and play functionality for all measuring systems and environmental control units – the Kinexus Prime DSR Series enables...

Open the catalog to page 4
Kinexus Prime DSR Series - 5

Environmental cartridges are easily changed or removed for service All modes of operation – stress, shear rate and direct strain controlled oscillation Exceptional vertical travel and gapping capabilities with ultra-responsive and highly sensitive Normal Force for dedicated pull-off, tack and penetration testing Unique rSpace software interface that offers total flexibility of test set-up, from sequence-driven Standard Operating Procedure (SOP)-type functionality to fully customizable test design Fully integrated materials database enables user friendly data management that can be tailored...

Open the catalog to page 5
Kinexus Prime DSR Series - 6

High axial and radial stiffness for increased robustness and reduced compliance 10 Features of the ∙ Kinexus Prime DSR ∙ ∙ Series minimize compliance and inertia Quick-connect push-fit design and integrated RFID tag (auto-detection) allows for reduced time to measurement while ensuring the correct measuring system and calibration constants are always used High precision rotational system 3 Accurate measurement of rotor position and speed Optical encoder with nanometer resolution for measuring minuscule radial displacements and speeds Sample response optimized by locating the sensor as close...

Open the catalog to page 6
Kinexus Prime DSR Series - 7

Environmental control cartridge/lower measuring system Provides fast lower geometry interchange, plus temper ature and environmental control Unique plug and play cartridge system with auto-recognition All mechanical, power, communication and fluid connections made in one simple action Cartridge options include: Asphalt Peltier Plate, active hood design Universal cylinder; for cub-bob & torsion High temperature; for polymer melts & curing Geometries available in a wide range of sizes, materials and surface finishes Lower measuring system can be secured and removed easily using a simple slide...

Open the catalog to page 7
Kinexus Prime DSR Series - 8

MEASURING SYSTEMS AND ACCESSORIES Active hood cartridge (-40°C to +150°C) environmental controller with minimized thermal gradients for plate measuring systems Peltier cylinder cartridge (-30°C to +200°C) environmental controller for concentric cylinder-type measuring systems HTC Prime Cartridge (0°C to 450°C) Cutting-edge temperature control in HTC Prime, inspired by thermal analysis technology Applicable to the measurement of highly thermally-sensitive samples, and for temperaturecritical testing Proprietary design incorporates state-of-the-art heating technology with Peltier elements to...

Open the catalog to page 8
Kinexus Prime DSR Series - 9

KINEXUS PRIME DSR ACCESSORY SPECIFICATIONS Measuring systems Quick-connect geometries with intelligent RFID auto-recognition linked to database Lock-down tests to specific geometry to minimize operator error Standard upper plates of 4 mm, 8 mm, and 25 mm to conform to AASHTO, ASTM & EN standards, with disposable options also available Coaxial cylinders (cup and bob) to DIN standard with double gap and vane tool options also available Geometry adapter allows use of custom geometries (e.g., penetration probes) Automatic temperature calibration device available Tribology kit for friction...

Open the catalog to page 9
Kinexus Prime DSR Series - 10

Unprecedented Dual-Action Capabilities A Revolution in Shear and Vertical (Axial) Test Control The unique combination of Kinexus Prime DSR hardware technology and rSpace software gives the user the ability to configure three critical rheometer functions independently: R otational (shear) control – torque, speed and position Vertical (axial) control – gap and Normal Force Temperature control Offering the ultimate in rheological test flexibility for both industry and academia, Kinexus enables: All rotational shear-based testing Advanced vertical (axial) testing including squeeze flow and tack...

Open the catalog to page 10
Kinexus Prime DSR Series - 11

Significant design effort has been directed at the vertical, or axial capabilities of the Kinexus Prime DSR platform – an area that typically sees compromises on most rheometer systems. AASHTO T315 AASHTO T316 AASHTO T350 AASHTO TP70 AASHTO TP101 AASHTO TP123 AASHTO TP126 AASHTO M320 AASHTO M332 Kinexus Prime DSR combines high speed and ultra-fine resolution gap control with high sensitivity and ultraresponsive Normal Force control for truly innovative sample loading and measurement capabilities – from sensitive structures to rapid curing systems. Allied to cradle to grave data collection...

Open the catalog to page 11
Kinexus Prime DSR Series - 12

rSpace Software Standard Operating Procedure (SOP) Driven Tests for Robust Rheological Measurements The Standard Operating Procedure (SOP) approach to material testing has been a cornerstone to all our technologies, and is now available for the first time on a rheometer system. rSpace can be used for simple QC operation or for advanced rheological testing C ontinuous feedback and user guidance at all times E nsure best rheological practice A dd specific test controls relevant to your samples P roduce standard test methods for your samples A vailable for use company-wide C onsistent...