Group: NETZSCH
Catalog excerpts
Rosand Series Proven Excellence in Rheology Analyzing & Testing
Open the catalog to page 1The Importance of Rheology Phase Behavior, Microstructure, Molecular Weight, Compatibility Formulation, Fillers, Additives Kinexus Prime Rotational Rheometer Product Application, Spreadability, Aesthetics, Mouthfeel, Levelling, Sag Resistance, Tack, Adhesion In-Use Processes, Product Dispensing, Pouring, Sprayability 2
Open the catalog to page 2Rotational and Capillary Rheology WITH OVER 14 DECADES OF SHEAR RATE Processing, Extruding, Injection Moulding Rosand Capillary Rheometer Product Appearance, Particle Suspending Capability, Stability, Homogeneity THE HEART OF FORMULATION AND PRODUCTION FROM FORMULATION AND PROCESSING TO END-USE PRODUCT PERFORMANCE 3
Open the catalog to page 3Powerful Floor Standing Capillary Rheometers for Research and Product Development Flexible measurement capabilities for materials under high pressure and high shear rate extrusion Since its launch, the Rosand RH7 and RH10 have set new standards in research level capillary rheometry. Today, the Rosand is used in hundreds of research laboratories around the world for a range of applications including polymers, foods, coatings and ceramics. Continuous development of the original design and its operating software has produced a generation of floor standing capillary units with market leading...
Open the catalog to page 4Advanced Benchtop Capillary Rheometers for Research, Product Development and Quality Control Wide range of shear rates for correlation with real material processing conditions, in one compact system The Rosand RH2000 series of benchtop capillary rheometers are compact systems capable of most testing requirements encountered in capillary rheometry. The series is available in both single bore or twin bore configurations. The RH2000 incorporates many of the features and attributes found in the floor standing models (Rosand RH7/RH10). A digital drive system gives the RH2000 series unsurpassed...
Open the catalog to page 5Capillary Rheometer HOW THE SYSTEM WORKS Capillary Rheometer Base Unit The Rosand high pressure capillary rheometer systems enable controlled extrusion (by volumetric flow) of a sample through a high precision die of known dimensions. This enables characterization of material flow properties, typically under conditions of high force (or pressure) and/or high shear rate. Using the twin bore barrel option and a zero length die configuration allows, simultaneous determination of shear viscosity and extensional (elongational) viscosity as a function of shear (or deformation) rate can be...
Open the catalog to page 6Edge Failure at the Rotational Rheometer 10-1 10-2 Rotational test 1 Rotational test 2 Capillary test 1 with 0.5mm capillary die Measurements in capillary rheometers to die understand material behaviour during processing, Capillary test 2 are withoften 0.5mmused capillary Capillary 3 with 0.25mm capillary die – depending on the shear rates applied. and to a smaller extent, during thetest application of the product Capillary test 4 with 0.25mm capillary die 103 From Production to Application – NETZSCH Rheometers Can Do it All! PA6 vol% GF Shower gels like many other personal care products...
Open the catalog to page 7Features of Rosand Rheometers Rosand Twin Bore Principle Bi-Modal Speed Control Rosand capillary rheometers were the first to introduce the twin bore measurement principle to the commercial market. Simultaneous measurements can be made on both long and short dies to determine the inlet pressure drop at the die and, therefore, absolute viscosity, using the Bagley method. More commonly, Rosand zero length dies are used to directly measure the inlet pressure drop and measure the extensional viscosity using the Cogswell method. Bi-modal digital speed control technology has been developed for...
Open the catalog to page 8Rigid H Frame Design The H frame design principle provides a vertical stiffness well in excess of that achievable with cantilever or C frame designs. The frame is effectively rigid at loads well in excess of the 100 kN measurement limit. This is an important consideration in transient tests such as pVT, which rely upon compliance free measurement for accurate volume determination. Integral Fume Chamber with Extraction For operator safety, the RH7 and RH10 are equipped with a safety interlocked fume chamber with fan extraction of the gases to a vent at the back of the rheometer unit. An...
Open the catalog to page 9Configuration Options The Rosand capillary rheometers can be configured with a variety of options to provide complete measurement solutions across all applications. High Force Extends the maximum force (summed over both barrels if applicable) to 20 kN for the RH2000. The RH7 and RH10 have forces of 50 and 100 kN, respectively. High Speed An option for the RH2000. It extends the upper speed limit of the unit to 1200 mm/min for high shear rate measurement with no loss in speed sensitivity or available force. The high speed option is fully compatible with the high force option. An advanced,...
Open the catalog to page 10Accessories Several accessories are available to suit particular applications and enhance the testing capability of the base units. Main Accessories for the RH2000: Alternative test dies Alternative pressure transducers Nitrogen purge Die and melt cutters Laser die swell measurement Several accessories are available to suit particular applications or enhance the testing capability of the base units. Main Accessories for RH7 and RH10: Alternative test dies Alternative pressure transducers Nitrogen purge Tragethon haul-off (melt strength) Melt tension apparatus with automatic spooling Laser...
Open the catalog to page 1117. Runs the 12. Opens an existing current test 17. Runs the Continuous development of the Rosand Flowmaster test (.RTS file) current tes software has produced a comprehensive data acquisition and analysis package. Flowmaster offers a wide range of measurement options in multiple languages with an extensive help system. 13. Saves test setup (not18. results) to .RTS Saves testfileresults 1. Opens a graph to .RTD file overlay file FLOWMASTER SOFTWARE 14. Writes test documentation (or views existing documentation) 2.19. Opens a graph Opens the overlay file Window Analysis Software Modules and...
Open the catalog to page 12All NETZSCH Analyzing & Testing catalogs and technical brochures
-
DMA 303 Eplexor
24 Pages
-
LFA 717 HyperFlash® Series
28 Pages
-
DSC 300 Caliris Series
28 Pages
-
STA 509 Jupiter Series
28 Pages
-
TG 309 Libra Series
24 Pages
-
DEA 288 Ionic
20 Pages
-
STA 2500 Regulus
12 Pages
-
NTA Guarded Hot Plate Series
16 Pages
-
TMA 402 F1/F3 Hyperion®
16 Pages
-
Accelerating Rate Calorimetry
20 Pages
-
NTA HotBoxes
16 Pages
-
DIL 402 Expedis Select/Supreme
28 Pages
-
DIL 402 Expedis Classic
16 Pages
-
Product Overview
12 Pages
-
NETZSCH Energy Solutions
40 Pages
-
Advanced Materials Testing
32 Pages
-
NTA Fire Testing Systems
20 Pages
-
Kinetics NEO
20 Pages
-
TG-FTIR - product brochure
24 Pages
-
TA-QMS Coupling
28 Pages
-
Kinexus Prime DSR Series
20 Pages
-
Kinexus Prime Series
20 Pages
-
HMOR 422
1 Pages
-
RUL/CIC 421
1 Pages
-
Cone Calorimeter TCC 918
12 Pages
-
Thermal Insulation Materials
24 Pages
-
SBA 458 Nemesis®
24 Pages
-
NETZSCH NEVIO Instrument Series
24 Pages
-
LFA 427 - product brochure
24 Pages
-
DMA GABO EPLEXOR up to 1500°C
12 Pages
-
GABOMETER®
8 Pages