Group: NETZSCH
Catalog excerpts
GABOMETER® Intelligent Universal Flexometer Analyzing & Testing
Open the catalog to page 1GABOMETER® Intelligent Material Testing Our GABOMETER® system – developed on the basis of the established Goodrich Flexometer – provides accurate measurements of heat build-up as well as blow-out tests and determination of the thermal set. Both force- and elongation-controlled tests can be carried out with this state-of-the-art flexometer. The GABOMETER® is well suited to the task of improving the thermal dissipation and durability of semi-finished tire components, dampers or absorbers. Optionally, the new generation can also measure a material’s stiffness (E modulus) and damping (tan δ)...
Open the catalog to page 2■ Heat build-up and blow-out tests according to Goodrich (DIN 53 533, ASTM D 623, ISO 4666/3, ISO 4666/4, BS 903 part A50 and JIS K 6265) ■ Compression set ■ Dynamic visco-elastic properties* ■ Tension flexometer tests* ■ Fatigue tests* ■ Programmable generator board for variable waveforms with automatic self-adjusting signal shape feedback loop* ■ Creep test* ■ Triple temperature measurement ■ Temperature sensor underneath the sample (standard) ■ Temperature sensor for chamber control (standard) ■ Temperature sensor at the core of the sample (needle type)* Intelligent Universal Flexometer
Open the catalog to page 3Heat build-up and blow-out tests according to Goodrich (DIN 53 533, ASTM D 623, ISO 4666/3, ISO 4666/4, BS 903 part A50 and JIS K 6265) Goodrich flexometer tests Static: Strain- or stress-controlled load mode Dynamic: Strain- or stress-controlled load mode Wide frequency range* Wide temperature range* Automatic sample changer (ASC) for fully automatic testing (24h)* Simultaneous measurement of the visco-elastic properties* Visco-elastic properties in DMA mode* Hysteresis
Open the catalog to page 4Heat build-up of ASTM D 623 SBR reference Glass transition Complex Modulus in MPa Modulus in MPa Complex Complex Modulus in MPa Complex Modulus in MPa Modulus in MPa Complex Complex Modulus in MPa Temperature in °C Temperature in ° Temperature in °C GOODRICH FLEXOMETER TESTS Dynamic strain sweep up to 100 % 100 0 10 -1
Open the catalog to page 5Measuring Principle Phase-shift δ Servo motor with static drive Optical sensor for static strain Sample Optical sensor for dynamic strain GABOMETER® measuring principle Force sensor Force amplitude Strain amplitude Phase-shift between force and strain is a measured amount in DMA mode Automatic Sample Changer (ASC) Option The optional automatic sample changer comprises a compression magazine for up to 60 specimens. A robot grip system pulls the samples out of the magazine and transfers them to the GABOMETER®.
Open the catalog to page 6Test specimen size (diameter/thickness) Static load drive Dynamic load drive Frequency range Static strain range Dynamic strain range Force range Temperature range Shaker for servo motor* Electrodynamic shaker system 30 Hz 0.5 up to 50 Hz continuously* up to 60 mm ± 1.5 mm up to ± 10 mm* up to 2000 N (-160°C) RT up to 300°C Shaker for servo motor* Electrodynamic shaker system 30 Hz 0.5 up to 50 Hz continuously* up to 60 mm ± 1.5 mm up to ± 10 mm* up to 4000 N (-160°C) RT up to 300°C Temperature measurement Mode A: Temperature in the furnace PT 100 or type K thermocouple Mode B: Temperature...
Open the catalog to page 7The NETZSCH Group is a mid-sized, family-owned German company engaging in the manufacture of machinery and instrumentation with worldwide production, sales, and service branches. The three Business Units - Analyzing & Testing, Grinding & Dispersing and Pumps & Systems - provide tailored solutions for highest-level needs. Over 3,500 employees at 210 sales and production centers in 35 countries across the globe guarantee that expert service is never far from our customers. When it comes to Thermal Analysis, Calorimetry (adiabatic & reaction) and the determination of Thermophysical Properties,...
Open the catalog to page 8All NETZSCH Analyzing & Testing catalogs and technical brochures
-
DSC 300 Caliris Series
28 Pages
-
STA 509 Jupiter Series
28 Pages
-
TG 309 Libra Series
24 Pages
-
DEA 288 Ionic
20 Pages
-
STA 2500 Regulus
12 Pages
-
NTA Guarded Hot Plate Series
16 Pages
-
TMA 402 F1/F3 Hyperion®
16 Pages
-
Rosand Series
20 Pages
-
Accelerating Rate Calorimetry
20 Pages
-
LFA 467 HyperFlash® Series
28 Pages
-
DMA 303 Eplexor
24 Pages
-
NTA HotBoxes
16 Pages
-
DIL 402 Expedis Select/Supreme
28 Pages
-
DIL 402 Expedis Classic
16 Pages
-
Product Overview
12 Pages
-
NETZSCH Energy Solutions
40 Pages
-
Advanced Materials Testing
32 Pages
-
NTA Fire Testing Systems
20 Pages
-
Kinetics NEO
20 Pages
-
TG-FTIR - product brochure
24 Pages
-
TA-QMS Coupling
28 Pages
-
Kinexus Prime DSR Series
20 Pages
-
Kinexus Prime Series
20 Pages
-
HMOR 422
1 Pages
-
RUL/CIC 421
1 Pages
-
Cone Calorimeter TCC 918
12 Pages
-
Thermal Insulation Materials
24 Pages
-
SBA 458 Nemesis®
24 Pages
-
NETZSCH NEVIO Instrument Series
24 Pages
-
LFA 427 - product brochure
24 Pages
-
DMA GABO EPLEXOR up to 1500°C
12 Pages