LaserGas-iQ2

LaserGas-iQ2

LaserGas-iQ2

Product catalog summary
Overview: The LaserGas™ iQ2 by NEO Monitors is an advanced gas analyzer capable of measuring up to four gases (O2, CO, CH4, H2O) and temperature, designed to replace multiple units in combustion analysis. It offers high reliability, durability, and reduced installation costs with an optional single flange solution.
Key Features:
  • Measures up to 5 components: O2, CO, CH4, H2O, and temperature.
  • Handles combustion processes up to 1300°C (2372°F).
  • Low maintenance and easy installation with a single transceiver unit.
  • Double path length for enhanced signal absorption in low concentrations.
  • Factory calibrated with no zero drift and no interference from background gases.
  • Multiple configurations: cross stack, one-flange with probe, and open path.
  • Automatic gain and in-situ measurement capabilities.
Applications: Suitable for combustion analysis, FCC units, package boilers, process heaters, electrostatic precipitators, VCM waste gas recovery, reformer gas, and incineration.
Technical Specifications:
  • Max process gas temperature: 1300°C.
  • Max process gas pressure: 1.5 barA.
  • Optical path length: up to 20m.
  • Response time: ≤ 5 seconds.
  • Operating temperature: -40°C to +55°C.
  • Storage temperature: -40°C to +70°C.
  • Protection classification: IP66.
  • Power supply: 24 VDC (18 - 30 VDC), max 30W consumption.
  • Laser class: Class 1M, eye safe.
  • Approvals: IECEx/ATEX zone 1, CSA Class I Div. 2.
Installation and Maintenance:
  • Flange dimensions: DN 80/PN 10-40 or ANSI 3’’ #150 (#300).
  • Instrument purge: N2 or air, application dependent.
  • Calibration recommended every 12 months.
  • In-situ span check with optional internal cell.
Performance Ranges:
  • CO Range: 0-100ppm to 0-10000ppm*m, precision 1 ppm.
  • O2 Range (N2 purge): 0-2% to 0-25%, precision 0.02%.
  • CH4 add-on: 0-1%*meter to 0-5%*meter, precision 0.01%.
  • Temperature add-on (N2 purge): -40°C to 500°C, precision 15°C.
See more

Catalog excerpts

LaserGas-iQ2-1

All Rights Reserved, Copyright © June 2018, NEO Monitors AS NEO Monitors LaserGasTM iQ2 analyzer is the first to measure up to four gases (O2, CO, CH4, H2O)** and temperature depending on configuration, which eliminates the need for multiple units for combustion analysis. The cutting-edge design and ground-breaking functionality, ensures that the instrument delivers unmatched reliability and durability. By providing an optional single flange solution, installation cost can be significantly reduced. Customers may replace existing analyzers where explosion risks or high maintenance issues are a huge concern. Customer benefits • No interference from background gases • Combustion analysis • Factory calibrated • Up to 5 measuring components O2, CO, CH4, H2O and temperature • Package boilers • No zero drift • Transceiver configuration • Multiple configurations • Designed for 3 configurations – cross stack, one-flange with probe and open path • Automatic gain • In-situ measurement • Integrated span check option (Application dependent) • FCC units • Process heaters • Electrostatic precipitators • VCM waste gas recovery • Reformer gas • Incineration • Can handle a typical combustion process up to 2372 °F/1300°C • Reduced installation cost • Low maintenance cost • Easy to install transceiver, one unit ensures easy alignment • Double path length increases absorption signal for low concentration • Transceiver can be mounted on coldest side of stack in extreme hot environments • Well proven technology • The design has flexibility to measure new/ other gases and combinations of them NEO Monitors AS • Part of the Nederman Group • Prost Stabels vei 22 • N-2019 Skedsmokorset, Norway

 Open the catalog to page 1
LaserGas-iQ2-2

LaserGas™ iQ2 Technical Data Specifications Max. process gas temprature: Optical path length: Ratings Power supply: Power consumptions: Response time: Storage temperature: Protection classification: Safety Laser class: CE: Environmental conditions Operating temperatures: -40 °C - +55 °C Relay output: Class 1M according to IEC 60825-1, eye safe Certified Approvals IECEx/ATEX zone 1: Input/output Analog output: Digital output: Ethernet (TCP/IP) High gas, warning and fault (normally closed) 4 - 20 mA Process temperature and pressure reading Conformant with directive 2014/30/EU II 2 D Ex pxb IIIC...

 Open the catalog to page 2
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.