Overview
NEO Monitors' LaserGas™ iQ2 Vulcan is an advanced in-situ single-flange solution designed to measure up to four gases (O2, CO, CH4, H2O) and process temperature in a single unit. Utilizing tunable diode laser absorption spectroscopy (TDLAS) technology, it offers a comprehensive combustion solution that reduces the need for multiple units, thereby lowering installation and maintenance costs.
Key Features
  • Measures up to five components: O2, CO, CH4, H2O, and temperature.
  • Handles combustion processes up to 850°C (1562°F).
  • Reduced installation and maintenance costs with easy-to-install transceiver.
  • Double path length for enhanced absorption signal in low concentrations.
  • No interference from background gases and factory calibrated with no zero drift.
  • Automatic gain and in-situ measurement capabilities.
  • Span check/validation option for O2, CO, and CH4.
Applications
  • Combustion analysis.
  • Package boilers and process heaters.
  • Electrostatic precipitators and VCM waste gas recovery.
  • Reformer gas applications.
Technical Specifications
  • Max process gas temperature: 850°C.
  • Max process gas pressure: 1.5 BarA.
  • Response time: 5 seconds.
  • Operating temperature range: -40°C to +55°C.
  • Storage temperature range: -40°C to +70°C.
  • Protection classification: IP66.
  • Power supply: 24 VDC (18 - 30 VDC), max power consumption 30W.
  • Laser class: Class 1M, eye safe according to IEC 60825-1.
  • Approvals: IECEx/ATEX zone 1, CSA Class I Div. 2.
Installation and Operation
  • Flange dimensions: DN80/PN 10-40, DN100/PN 10-40, ANSI 3” #150/#300, ANSI 4” #150/#300.
  • Instrument and probe purge with nitrogen.
  • Calibration check recommended every 12 months.
Dimensions and Weight
  • iQ2 dimensions: 461 mm x 399 mm x 174 mm, weight: 15 kg.
  • Probe dimensions: 1495.8 mm x Ø 63.5 mm, weight: 32 kg.
Detection Limits
  • CO: 10000 ppm, LDL 3 ppm.
  • O2: 25%, LDL 0.05%.
  • CH4 add-on: 5%, LDL 0.01%.
See more

Catalog excerpts

LaserGas-iQ2-Vulcan-1

All Rights Reserved, Copyright © June 2018, NEO Monitors AS NEO Monitors’ LaserGasTM iQ2 Vulcan is the first in-situ single-flange solution to measure up to four gases (O2, CO, CH4, H2O) as well as the process temperature in a single unit. Based on the well-proven and trusted tunable diode laser absorption spectroscopy (TDLAS) technology, the solution combines cutting-edge design and ground-breaking functionality. It is a complete combustion solution eliminating the need for multiple units. Advanced TDLAS technology enables unmatched reliability and durability. Installation costs of this all-in-one solution are significantly reduced since only one flange is needed. In addition, operational and maintenance costs are kept at a minimum. Customer benefits • No interference from background gases • Combustion analysis • Factory calibrated • Up to 5 measuring components O2, CO, CH4, H2O and temperature • Process heaters • No zero drift • Transceiver configuration • Automatic gain • In-situ measurement • Span check/validation option for O2, CO, and CH4 • Package boilers • Electrostatic precipitators • VCM waste gas recovery • Reformer gas • Can handle a typical combustion process up to 1562 °F/850°C • Reduced installation cost • Low maintenance costs • Easy to install transceiver, one unit ensures easy alignment • Double path length increases absorption signal for low concentration • Well-proven technology NEO Monitors AS • Part of the Nederman Group • Prost Stabels vei 22 • N-2019 Skedsmokorset, Norway Phone +47 67 97 4

 Open the catalog to page 1
LaserGas-iQ2-Vulcan-2

LaserGas™ iQ2 Vulcan Technical Data Specifications Max. process gas temperature: Max. process gas pressure: Optical path length: Response time: Environmental conditions Operating temperatures: Storage temperature: Protection classification: Input/output Analog output(6): Digital output: Relay output (6): Ethernet (TCP/IP) 4 - 20 mA Process temperature and pressure reading High gas, warning and fault (normally closed) Power consumptions: Relay output: Safety Laser class: Ratings Power supply: Class 1M according to IEC 60825-1, eye safe Conformant with directive 2014/30/EU Calibration check: Approvals...

 Open the catalog to page 2
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.