DOC-2000

DOC-2000

DOC-2000

Product catalog summary
Overview
The DOC-2000 is a distribution transformer tester designed for de-energized transformers. It identifies short circuits or open circuits in the primary winding and short circuits in the secondary winding without disconnecting the secondary windings.

Specifications
  • Supports transformers up to 167 KVA, single or three-phase.
  • Operates in temperatures from -25°C to 55°C (-13°F to 131°F).
  • Battery operated with a PP3 9V battery.
  • Conforms to IEC-TC78 safety standards.

Features
  • Contact measurement on transformer primary bushing and neutral/ground.
  • Visual and audible warnings for diagnostics.
  • Automatic self-test and auto shut-off features.
  • Low battery indicator.

Advantages
  • Eliminates the need to disconnect transformer secondary windings, saving time.
  • Reduces hazards when re-energizing transformers with shorted windings.

Operation
The DOC-2000 is used by linemen to safely determine if it is safe to re-energize transformers after outages caused by storms or line faults. It helps prevent energy ruptures by identifying faulty circuits before re-energization.

Included Items
  • DOC-2000 instrument with hook type probe.
  • Pin type probe.
  • Transportation bag.
  • User manual and laminated quick reference guide.
  • Calibration certificate.
See more

Catalog excerpts

DOC-2000-1

Distribution Transformer Tester The DOC-2000 is intended for de-energised distribution transformer testing. It can determine the presence of short circuits or an open circuit in the distribution transformer primary winding and also short circuits on the secondary winding. The DOC-2000 is designed to be operated from an arial device or from the ground at the end of a hot stick without disconnecting the transformer’s secondary windings No need for disconnecting transformer secondary windings therefore saving time Reduces risks of hazards when putting fuses back online when the transformer windings are shorted Conformity with the requirements for safety (IEC-TC78 ) Transformers up to 167 KVA single or three phase (Pole mount or Pad mount) Measurement by contact on the transformer primary bushing and neutral/ground Used on de-energized transformers Detects primary transformer short-circuit, open circuit, & secondary short circuits Visual and audible warning. Automatic self-test & Auto shut-off Low battery indicator Operating temperature range -25°C to 55°C EASY OPERATION The instrument requires an electrical connection to the primary bushing and the system ground (neutral). The DOC-2000 displays the diagnostic readings with a visual and audible signal. The DOC-2000 kit includes the test instrument, contact electrodes ( Pole mount hook & Pad mount pin ) and a carrying case. ndb Technologies inc. • 1405 St-Jean-Baptiste, office 111 • Quebec (QC) G2E 5K2 - Canada • Tel: 1(418)877-7701 Fax: 1(418)877-7787 Email: [email protected]

 Open the catalog to page 1
DOC-2000-2

TECHNICAL SPECIFICATIONS Supported transformers up to 167 KVA single or three phase Hook type probe and pin type probe Operating temperature Power supply OPERATION Linemen crews are called on to re-energize transformers regularly, whether it’s after storms or when line faults occurs etc... The reasons for the outages are not always obvious, but the power needs to get back on. When damaged or connected to a faulty circuit, the transformers can rupture with massive amount of energy when attempting to re-energize. In order to make a better decision whether it is safe to re-energize the transformer...

 Open the catalog to page 2
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.