NCS-CEMS
12Pages

{{requestButtons}}

Catalog excerpts

NCS-CEMS - 1

NCS-CEMS VOCs Continuous Emission Monitoring System

Open the catalog to page 1
NCS-CEMS - 2

About Us NCS Testing Technology CO., Ltd. (hereinafter referred to as NCS) is the wholly owned subsidiary of China Iron & Steel Research Institute Group (CISRI). It is the New and High-tech Enterprise and found by the business integration of National Analysis Center for Iron and Steel, China National Center for Quality Supervision and Testing of Iron and Steel, Analysis and Testing Institute of Central Iron & Steel Research Institute, National Nondestructive Testing Center for Steel Products, Analysis and Testing Training Center of Central Iron & Steel Research Institute, Qingdao Marine...

Open the catalog to page 2
NCS-CEMS - 3

NCS-CEMS VOCs Continuous Emission Monitoring System Overview Featured with stable and reliable performance, high degree of automation and ppb-grade high detection sensitivity, NCS-CEMS volatile organic compounds online monitoring system is produced by conducting indepth development and integrated design of the advanced technology introduced from abroad. By adopting the measuring principle of gas chromatography photo-ionization Detector (GC-PID), gas chromatography ion mobility spectrometry (GC-IMS) and hydrogen flame ionization detector (FID), this instrument can follow the measurement...

Open the catalog to page 3
NCS-CEMS - 4

Application Oil refining; Petrochemical / chemical industry; Electronic / semiconductor; Medicine; Automobile; Printing and dyeing; Coating;Rubber; Environmental protection; Electric power and energy; Food; Metallurgy; Oil and gas engineering; Ship / military industry; Leather processing;Industrial gas. Product features ■ Automatic calibration and automatic zero correction, no need for manual operation, and little maintenance. ■ Adoption of dual cycle PID system, no need for any carrier gas, and low safety maintenance. ■ Intrinsic safety type installation and high explosion-proof grade. ■...

Open the catalog to page 4
NCS-CEMS - 5

NCS-CEMS VOCs Continuous Emission Monitoring System Main technical index of the system Detector Flame Ionization Detector(FID) Photoionization Detector(PID) Ion mobility spectroscopy(IMS) Monitoring substance Response time Zero/Span drift Detection limit Data unit Work environment System Composition Figure 1 Functional diagram

Open the catalog to page 5
NCS-CEMS - 6

NCS-CEMS VOCs Continuous Emission Monitoring System VOCs detection subsystem Sampling unit (probe, filter, thermostat) sampling line instrument cabinet (electric heating constant power Pretreatment unit  (sampling pump, Other parts fine filtration, drainage, etc.) Back flushing unit Analysis unit factor allocation)

Open the catalog to page 6
NCS-CEMS - 7

NCS-CEMS VOCs Continuous Emission Monitoring System This instrument is provided with a two-way diaphragm pump with one way used for sampling the other for internal circulation of carrier gas. There is no need for carrier gas during the application process, which can greatly reduce the costs of operation and maintenance at the later stage. In the process of sampling, the sample is completely in the flow state, and there is no existence of dead volume. Upon the entry of analysis process, samples can be led by carrier gas into the chromatography and detector through the fast switching of gas...

Open the catalog to page 7
NCS-CEMS - 8

NCS-CEMS VOCs Continuous Emission Monitoring System The flue gas monitoring subsystem is composed of humidity transmitter, pressure transmitter, flow transmitter and temperature transmitter. Technical Parameters Measuring range: 0-40 m/ss Measuring accuracy: ±5%FS Frequency of calibration: 12 months Response time: <1s Output signal: 4~20mA square-root proportional current, two-wire system Differential pressure (temperature, pressure) transmitter power supply: 24VDC, two-wire system Overvoltage limit of differential pressure transmitter: 4.0MPa Pitot tube material: 304, 316, 316L stainless...

Open the catalog to page 8
NCS-CEMS - 9

NCS-CEMS VOCs Continuous Emission Monitoring System Data acquisition and processing system Constituted by the data acquisition system, industrial control computer, display and system software, the system collect the data from VOCs monitoring subsystem and flue gas monitoring subsystem, and upload to the environmental protection department via the data acquisition instrument. Based on the requirements of environmental protection departments in different regions, it is possible to transmit by directly enabling the analysis meter to be switched in the data acquisition instrument. Integrated...

Open the catalog to page 9
NCS-CEMS - 10

NCS-CEMS VOCs Continuous Emission Monitoring System Integrated industrial control computer Size:341.5×87×41.1mm(H*L*W) Work environment:-20~60℃ Weight: 8kg Power:220VAC/28W Integrated industrial control computer: CPU J1900 quad core master frequency 2.0GHZ, hard disk 64G (SSD) or 500G (mechanical hard disk), memory 4GDDR, 5-way RS232 and 1-way RS485, 2-way analog input and output, 1-way relay output, 1-way Ethernet output, 6 USB ports, connectivity with mouse, keyboard, remote control and mobile storage equipment etc. The aluminum box structure has good shock-resistance and impact...

Open the catalog to page 10
NCS-CEMS - 11

NCS-CEMS VOCs Continuous Emission Monitoring System Software Satisfaction to various kinds of data exchange protocols, and acquisition of data via data exchange protocols when needed. Be capable of recording all instrument operating parameters, such as sampling conditions, temperature, pressure, etc. Accurate calculation of sample volume according to the measured sampling flow and the sampling time. Be capable of automatically saving the information of important parameters at any time, possessing the self-diagnosis ability and tracking the fault cause and location when the instrument become...

Open the catalog to page 11
NCS-CEMS - 12

(§) NCS TESTING TECHNOLOGY CO.,LTD. Address: No.13, Xie Jie, Gaoliangqiao, Haidian District, Beijing Zip Code: 100081 Tel: +86(010)62182188 Fax: +86(010)62182155 Website: http://www.ncschina.com E-Mail: beijing@ncschina.com