1. Catalogs
  2. NC Technologies
  3. ECS 8060 created by NC Technologies

ECS 8060 created by NC Technologies

ECS 8060 created by NC Technologies

ECS 8060 created by NC Technologies

Product catalog summary
Overview
The ECS 8060 is a Nitrogen and Protein Analyzer developed by NC Technologies Srl, utilizing the Dumas combustion method for elemental analysis. It is designed for both nitrogen and carbon determination, offering versatility for a wide range of sample types and sizes, including both liquids and solids.
Specifications
The ECS 8060 features a dual furnace combustion system, a water extraction system using Permapure, a CO2 adsorption system by Zeoquantum, and a high-resolution Thermal Conductivity Detector (TCD). It operates fully automatically, with features such as automatic oxygen dosage and consumable status monitoring.
Features and Benefits
  • Fully automated analysis system with high sensitivity, accuracy, and precision.
  • Application flexibility and versatility, capable of simultaneous nitrogen and carbon determination.
  • Powerful software for results visualization and a touch-screen display for easy management.
  • Low operation and management costs with easy connection to Mass Spectrometers for isotopic analysis.
Analytical and Technical Features
  • Analysis time: 2 minutes for nitrogen, 8 minutes for CN.
  • Analytical range: 80 mg for nitrogen, 100 mg for carbon.
  • Accuracy and precision are less than 0.2% and 0.1% respectively, depending on sample nature and homogeneity.
  • Physical specifications include dimensions of 98x50x37 cm, weight of 78 kg, and power supply requirements of 230V, 50/60Hz.
Analytical Conditions
  • Gas carrier: Helium with automatic leak test and electronic flow rate control.
  • Furnace temperature: Maximum 1100°C for both left and right furnaces.
  • Sample size: 0.1-400 mg, typically 300 mg for food samples and up to 1 g for soil samples.
Accessories and Support
  • Includes a kit, balance, and proprietary consumables from NC Technologies Srl.
  • Assistance is available by phone or email within 24 hours.
See more

Catalog excerpts

ECS 8060 created by NC Technologies-1

N,Protein Analyzer ECS 8060 is a Nitrogen, Protein Analyzer Model making use of the Dumas combustion method. ECS 8060 is a state-of-the-art instrument for the elemental analysis based on sample combustion and separation of gases. The N2 combustion product is quantified by a high resolution TCD detector. CO2 is trapped in the innovative Zeoquantum system while H2O is condensed by specific Permapure trap. Fully automatically operated: from the available samplers to the oxygen dosage, from the monitoring of consumables status to the zeolite regeneration system. ECS 8060 Model is composed by: ü Dual furnace combustion system (for a better combustion and optimization of catalysts) ü Water extraction system by Permapure and water trap ü Carbon dioxide adsorption system by Zeoquantum ü Detection system ü Data acquisition and handling. NC Technologies Srl Sede legale: Via Grosio, 10/10 - 20151 Milano(MI), Italy - Sede amministrativa e operativa: Via Milano, 15/a - 20060 Bussero (MI), Italy Phone: ++39029503469 [email protected] - www.nctechnologies.it Cod. Fisc. P.IVA 09284300960, Registro Imprese Milano 09284300960, R.E.A. MI - 20807

 Open the catalog to page 1
ECS 8060 created by NC Technologies-2

ECS 8060 can be configured for nitrogen as well as for the CN determination. Very versatile, it is very useful for analysis of a wide range of sample types and sizes - both liquids and solids, from micrograms to grams of organic materials. Thanks to the absence of a GC column, sample weight limits are wider. Pneumatic, electric and manual samplers and high quality consumables are available. Automatisms make ECS 8060 particularly user-friendly: the automatic oxygen dosage system allows a better consumption of oxygen and consumable status monitoring function optimizes the catalysts to be used....

 Open the catalog to page 2
ECS 8060 created by NC Technologies-3

Analytical and Technical Features ECS 8060 Features Type Analysis Time Analytical Range Accuracy* Precision* Sampler <0,2% (certified standard; purity >99.9%) <0,1% (certified standard; purity >99.9%) Pneumatic autosampler 147 positions Manual sampler Dual Furnace System Safety Quick-fit Integrated water trap Zeoquantum C02 adsorption and desorption system Touch-screen display Stand-by mode * Accuracy and precision are related to samples nature and homogeneity. Physical Specifications Dimensions Weight Power Supply Absorbed Power Gas Requirements 98x50x37cm 78kg 230V, 50/60HZ 5A, 1100W. Helium...

 Open the catalog to page 3
ECS 8060 created by NC Technologies-4

Analytical Conditions Gas carrier Leak test Furnace temperature Oxygen volume need Flow Rate Water trap Detector Detector Detector Software data analysis Calibrations Active calibration Helium Automatic leak test Left furnace :1100°C max Right furnace: 1100°C max Automatically calculated by the oxygen doser Electronic flow rate control Efficient and easy maintenance High Sensitivity TCD High Sensitivity TCD High Sensitivity TCD EAS Clarity Linear, Ouadratic, cubic As necessary Sample Sample size Sample type Capsule 0.1-400 mg (depending on sample nature) typically 300 mg for food samples up to...

 Open the catalog to page 4
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.