ECS 8040 created by NC Technologies
11Pages

{{requestButtons}}

Catalog excerpts

ECS 8040 created by NC Technologies - 1

ECS8040 | ORGANIC ELEMENTAL ANALYZER CHNS-O Analyzer

Open the catalog to page 1
ECS 8040 created by NC Technologies - 2

ECS 8040 – CHNS-O Analyzer Organic Elemental Analysis ECS 8040 is a C-H-N-S-O Elemental Analyzer Model based on the Dumas combustion method. ECS 8040 is a state-of-the-art system for the elemental analysis based on sample combustion and separation of gases with a chromatographic column. The combustion products, i.e. CO2, H2O, N2 and SO2, are separated and quantified by a high resolution TCD detector. ECS 8040 is fully automatic, from the available samplers to the oxygen dosage, from the monitoring of consumables status to the automatic leak test.

Open the catalog to page 2
ECS 8040 created by NC Technologies - 3

ECS 8040 is composed by: Singlefurnace combustion system (for a better combustion and optimization of catalysts) Safety quick fit system for reactors connection (easy and safe way to set the instrument) Customized GC column Detection system Data acquisition and handling Several configurations may be set for the determination of the target element. Typical configurations are for: CHNS; CHN; CN; CNS; O Choose the best configuration by choosin g the right chemicals, consumables and prepacked reactors. The versatility of ECS 8040 can be expressed as: Sample weight Sample type Liquid or solid...

Open the catalog to page 3
ECS 8040 created by NC Technologies - 4

Three different samplers are available: Pneumatic autosampler up to 147 positions Electronic autosampler with 32, 50, 100 positions Manual sampler Leak Test ■unningg MaUjest^ Automatisms make it particularly user-friendly: Automatic oxygen dosage system (for a better consumption of oxygen and consumables) Automatic consumables status monitoring Automatic leak test Standby mode (gas, energy and time savings) Automatic oxygen dosage: main highlights. Details of sample are registered: Position Type Weight ECS 8040 will dose the oxygen for the right combustion. No oxygen or consumables...

Open the catalog to page 4
ECS 8040 created by NC Technologies - 5

EAS Clarity Powerful softwarefor powerful instrument Getting data, analyzing data, presenting data Integration There is extensive possibility to modify chromatograms. The chromatogram can be changed by entering global parameters or interactively, through direct graphic modification of the baseline. Overlay Simultaneously displays a virtually unlimited number of chromatograms and their mathematical modification. Calibration Internal and external standard calculation methods. Automated measuring support Sequence tables for any set of samples.

Open the catalog to page 5
ECS 8040 created by NC Technologies - 6

What the user can do Summary result tables Displays and prints selected results from all simultaneously displayed chromatograms. User settings User selects parameters for peak display and the specification for axes, including color from an extensive array of color settings. Text labels and lines, either as part of the area or anchored to a chromatogram, may also be inserted. Export Optional exportation of all results, with or without the chromatogram, in various formats, into a file or clipboard. Import Imports chromatograms or mathematical curves, which have been saved in text or...

Open the catalog to page 6
ECS 8040 created by NC Technologies - 7

ECS 8040 key points ü  Fully automated analysis system ü  High sensitivity, accuracy and precision ü  Consumables status monitoring for an optimization of catalysts usage ü  Three types of samplers available: electronic / pneumatic / manual. ü  Flexibility and versatility of applications ü  Detector does not require reference gas ü  Easy connection to Mass Spectrometers and other detectors for stable isotopes analysis ü  Powerful software for viewing results from a computer ü  Low operation and management costs ü  Touch-screen display for an easy settings management ü  Standby mode for gas,...

Open the catalog to page 7
ECS 8040 created by NC Technologies - 8

ECS 80 SERIES ECS 8040 application fileds ü  Environmental analysis ü  Organic chemistry and pharmaceutical ü  Petrol chemistry and energy ü  Soil science and geology- marine science (distinction between organic and inorganic carbon is available trough the previous acidification of the sample) ü  Materials characterization ü  Food (special configuration for big size samples is ea

Open the catalog to page 8
ECS 8040 created by NC Technologies - 9

Analytical and Technical Features Type Analysis time Analytical range Accuracy* Precision* Sampler CHNS-0 CN CHN CHNS 0 C H N S 0 <0.2% (certified standard; purity >99.9%) <0.1% (certified standard; purity >99.9%) Pneumatic autosampler Electronic autosampler Manual sampler Singlefurnace system Safety quick fit system Touch screen display Standby mode ■k Accuracy and precision are related to samples nature and homogeneity Dimensions Weight Power supply Adsorbed power Gas requirements 51x50x37 cm 53 kg 230V, 50/60Hz 4A, 900W Helium (99.999% purity), 3-5 bar Oxygen (99.999% purity), 3-5...

Open the catalog to page 9
ECS 8040 created by NC Technologies - 10

Analytical and Technical Features Analytical Conditions Gas carrier Leak test Furnace temperature Oven temperature Oxygen volume need Flow rate Gas separation Detector Software data analysis Calibration Active calibration Helium Automatic Left Furnace : max 1100°C RightFurnace : max 1100°C Max 110°C Automatically calculated by the oxygen doser Electronic Flow Rate 0.8-4 m GO Column High Sensitivity TCD EAS Clarity Linear, Quadratic, Cubic As needed Sample Sample size Sample type Capsule 0.1-500mg (depending on sample nature) Up to 1 g for soil samples Liquid Solid High purity tin and/or...

Open the catalog to page 10

All NC Technologies catalogs and technical brochures

  1. ECS8024

    11 Pages

  2. ECS8022

    11 Pages

  3. EA ID MICRO

    16 Pages