Overview: Navitar and DVC offer a cost-effective fluorescence imaging solution combining Navitar's Video ZFL Scope and DVC's scientific-grade digital cameras. This system provides sophisticated imaging capabilities without the complexity and expense of traditional research microscopes.
ZFL System Features:
  • Compact and affordable alternative to traditional microscopes.
  • Macro mode with a field of view up to 9.2 mm using a 2/3” CCD.
  • Micro mode with professional, infinity-corrected objectives.
  • BrightLight II light source with a long-life 4.8 watt LED.
  • Available in zoom and fixed systems with fine focus.
Suggested Uses:
  • Studies involving Green Fluorescent Protein (GFP) in living cells and tissues.
  • Plant cells, surfaces, soil samples, and parasite inspection.
  • Air and water pollution testing.
  • Forensic examinations including fingerprints, fibers, documents, and body fluids.
  • YFP and RFP labeled samples, colloidal gold labeled samples.
  • Small animal surgery and capillary flow observation.
  • Art restoration.
DVC Cameras Features:
  • Low noise and high quantum efficiency.
  • Various resolution options available.
  • Software selectable modes including dual-tap, 20/40MHz clocking, binning, and ROI.
  • Options for TE cooling and RGB color.
  • Gigabit Ethernet interface.
Software:
  • DVCView for Windows application.
  • Support for third-party software like Micro-Manager, LabVIEW, and ImageJ.
  • API/SDK available for Windows and Linux.
Camera Systems:
  • DVC340M-00-GE-S: Optimized for speed, 640 x 480 x 12-bits at up to 109 frames per second.
  • DVC1500M-00-GE-S: exVIEW HAD sensitivity, 1392 x 1040 x 12-bits at up to 23 frames per second.
  • DVC1500C-00-GE-S: RGB color version, 1392 x 1040 x 12-bits at up to 23 frames per second.

Note: For applications requiring long exposures, TE-cooling option is available.

Included Components:
  • Switching power supply.
  • PCIe GigE interface board.
  • 14ft GigE cable.
  • DVC software distribution disk.
Contact Information:
  • Navitar: Visit www.navitar.com or call 585.359.4000.
  • DVC: Visit www.dvcco.com or call 512.301.9564.
See more

Catalog excerpts

ZFL Video Fluorescence Scope - Macro Imaging-1

Fluorescence Imaging Powerful, Cost-Effective Solutions from DVC & Navitar Navitar’s Video ZFL Scope is a Macro/Micro fl uorescence vision system that utilizes interchangeable professional fl uorescence cubes and internal focus to create an image. It is a simple means of doing very sophisticated task-oriented fl uorescence imaging without the expense and complexity associated with a fully-loaded research microscope. DVC Company offers a variety of low noise, scientifi c-grade digital cameras and quantitative software that complement Navitar’s Video ZFL Scope. A powerful, yet cost effective fl uorescence imaging system is now possible by combining a DVC Camera with Navitar’s ZFL lens system. For more info on Navitar Visit: www.navitar.com Call: 585.359.4000 For more info on DVC Visit: www.dvcco.com Call: 512.301.9564 ZFL System: • Compact, lower cost alternative to traditional microscopes • Macro mode has a fi eld of view up to 9.2 mm with a 2/3” CCD • Micro mode utilizes professional, infi nity-corrected objectives • BrightLight II light source with long life 4.8 watt LED • Zoom and fi xed systems available, with fi ne focus Suggested Uses: • Green Fluorescent Protein (GFP) studies involving living cells and tissues: C. Elegans, D. Melanogaster, D. Rerio Larva, Zebra Fish, Oocytes, Nematodes, Drosophila DVC Cameras: • Low noise & High Quantum Effi ciency • Resolution - select from a range of offerings • Software selectable modes, including dual-tap, 20/40MHz clocking, Binning & ROI • Options - TE cooling, RGB Color • Gigabit Ethernet interface Software: • Application: DVCView for Windows • 3rd Party support: Micro-Manager, LabVIEW, ImageJ • API/SDK for Windows & Linux • Plant cells, plant surfaces, soil samples & parasite inspection • Air and water pollution testing • Examination of forensics - fi ngerprints, fi bers, documents and body fl uids • YFP and RFP labeled samples • Colloidal Gold labeled samples • Small animal surgery • Capillary fl ow observation • Art restoration

 Open the catalog to page 1
ZFL Video Fluorescence Scope - Macro Imaging-2

DVC Provides a Wide Range of Camera Systems Please select from the following partial list or visit www.dvcco.com for a wider selection. ƒÞ DVC340M-00-GE-S: optimized for speed, 640 x 480 x 12-bits @ up to 109f/sec ƒÞ DVC1500M-00-GE-S: exVIEW HAD sensitivity, 1392 x 1040 x 12-bits @ up to 23f/ sec* ƒÞ DVC1500C-00-GE-S: RGB color version of the above camera, 1392 x 1040 x 12-bits @ up to 23f/sec *If your fl uorescence imaging application requires long exposures, please contact DVC about adding the TE-cooling option. The above systems include the following: ƒÞ Switching power supply ƒÞ PCIe GigE...

 Open the catalog to page 2
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.