Catalog excerpts

BNC connectivity CompactDAQ counter compatibility Individually configurable channel directions The NI 9402 is a digital input/output module for any CompactDAQ or CompactRIO system. You can configure the direction of the channels for input or output on a per-channel basis. Each channel features 1,000 Vrms transient isolation between the channel and the backplane. With CompactRIO, you can use the LabVIEW FPGA Module to program the NI 9402 for implementing custom, high-speed counter/timers; digital communication protocols; pulse generation; and much more. • NI 9402 • NI 9402 Getting Started Guide • NI 9940 Backshell Kit (779567-01) • BNC-to-BNC Male Cables
Open the catalog to page 1
C SERIES DIGITAL INPUT/OUTPUT MODULE COMPARISON Product Name Signal Levels Update Rate Isolation Continuous NI provides more than 100 C Series modules for measurement, control, and communication applications. C Series modules can connect to any sensor or bus and allow for high-accuracy measurements that meet the demands of advanced data acquisition and control applications. • Measurement-specific signal conditioning that connects to an array of sensors and signals • Isolation options such as bank-to-bank, channel-to-channel, and channel-to-earth ground • -40 °C to 70 °C temperature range to...
Open the catalog to page 2
CompactDAQ CompactDAQ is a portable, rugged data acquisition platform that integrates connectivity, data acquisition, and signal conditioning into modular I/O for directly interfacing to any sensor or signal. Using CompactDAQ with LabVIEW, you can easily customize how you acquire, analyze, visualize, and manage your measurement data. Software LabVIEW Professional Development System for Windows Use advanced software tools for large project development Generate code automatically using DAQ Assistant and Instrument I/O Assistant Use advanced measurement analysis and digital signal processing...
Open the catalog to page 3
NI LabVIEW Real-Time Module Design deterministic real-time applications with LabVIEW graphical programming Download to dedicated NI or third-party hardware for reliable execution and a wide selection of I/O Take advantage of built-in PID control, signal processing, and analysis functions Automatically take advantage of multicore CPUs or set processor affinity manually Take advantage of real-time OS, development and debugging support, and board support Purchase individually or as part of a LabVIEW suite Circuitry Each channel on the NI 9402 can be configured in software for input or output....
Open the catalog to page 4
Input/Output Characteristics Number of channels Default power-on line direction Input/output type LVTTL, single-ended Digital logic levels Maximum input voltage Output high, VOH (3.4 V maximum) Sourcing 100 µA Maximum I/O switching frequency 4 channels 55 ns maximum, 18 ns typical 25 ns maximum Input high current, IIH (VIN = 4.5 V) Input impedance Input capacitance Input resistance Input rise/fall rate Input protection ±30 V maximum on one channel at a time 1,482,777 hours at 25 °C; Bellcore Issue 2, Method 1, Case 3, Limited Part Stress Method Propagation delay is the maximum amount of...
Open the catalog to page 5
Power Requirements Power consumption from chassis Active mode Sleep mode Thermal dissipation (at 70 °C) Active mode Sleep mode Physical Characteristics If you need to clean the module, wipe it with a dry towel. Cable Cable length Safety Voltages Connect only voltages that are within the following limits: Channel-to-earth ground Isolation Channel-to-channel Channel-to-earth ground Class I, Division 2, Groups A, B, C, D, T4; Class I, Zone 2, AEx nA IIC T4 Class I, Division 2, Groups A, B, C, D, T4; Class I, Zone 2, Ex nA IIC T4 Europe (ATEX) and International (IECEx) Safety and Hazardous...
Open the catalog to page 6
UL 60079-0; Ed 5, UL 60079-15; Ed 3 CSA 60079-0:2011, CSA 60079-15:2012 Note For UL and other safety certifications, refer to the product label or the Online Product Certification section. Electromagnetic Compatibility This product meets the requirements of the following EMC standards for electrical equipment for measurement, control, and laboratory use: • EN 61326-1 (IEC 61326-1): Class A emissions; Basic immunity • • • • EN 55011 (CISPR 11): Group 1, Class A emissions AS/NZS CISPR 11: Group 1, Class A emissions FCC 47 CFR Part 15B: Class A emissions ICES-001: Class A emissions Note For...
Open the catalog to page 7
Environmental Refer to the manual for the chassis you are using for more information about meeting these specifications. Operating temperature (IEC 60068-2-1, IEC 60068-2-2) Ingress protection Pollution Degree Maximum altitude Environmental Management NI is committed to designing and manufacturing products in an environmentally responsible manner. NI recognizes that eliminating certain hazardous substances from our products is beneficial to the environment and to NI customers. For additional environmental information, refer to the Minimize Our Environmental Impact web page at...
Open the catalog to page 8
Refer to the NI Trademarks and Logo Guidelines at ni.com/trademarks for information on NI trademarks. Other product and company names mentioned herein are trademarks or trade names of their respective companies. For patents covering NI products/technology, refer to the appropriate location: Help»Patents in your software, the patents.txt file on your media, or the National Instruments Patent Notice at ni.com/patents. You can find information about end-user license agreements (EULAs) and third-party legal notices in the readme file for your NI product. Refer to the Export Compliance...
Open the catalog to page 9All NATIONAL INSTRUMENTS catalogs and technical brochures
-
NI 9381
10 Pages
-
BNC-2121
3 Pages
-
Counter/Timer
10 Pages
-
NI PXIe-6612
12 Pages
-
ds-392
7 Pages
-
ETC_196
9 Pages
-
ds-293
13 Pages
-
ds-353
14 Pages
-
ds-361
5 Pages
-
NI WSN-3202
13 Pages
-
cat_ni31xx
5 Pages
-
PXI-4072 FlexDMM
5 Pages
-
GPIB-USB-HS
7 Pages
-
2005_6175_161_101
4 Pages
-
Digital I/O,
9 Pages
-
NI PCI-6624, NI PXI-6624
8 Pages
-
NI PCIe-6321
15 Pages
-
NI USB-6509
8 Pages
-
NI_PCI-6713.
5 Pages
-
NI_PCIe-6363
5 Pages
-
NI_GPIB-USB-HS
4 Pages
-
Counter_Timer_Devices
1 Pages
-
NI_EVS-1464
9 Pages
-
daqsc208-209_212-2
2 Pages
-
ds-153
18 Pages
-
ds-37
14 Pages
-
NI4065
6 Pages
-
4daqsc253
17 Pages
-
NI_1778_Smart_Camera
5 Pages
-
NI_PCI-5122
5 Pages
-
NI_EVS-1464_(Windows)
9 Pages
-
4daqsc253-265_194-196
17 Pages
-
NI-Datasheet-ds-293
13 Pages
-
NI_PXIe-8100_RT
3 Pages
-
NI_FPT-1015
3 Pages
-
NI_PXI-2501
5 Pages
-
2005_6174_161_101_d
5 Pages
-
cat_FET
3 Pages
-
cat_evs1464RT
9 Pages
-
4daqsc253-265
17 Pages
-
043918301101dlr
7 Pages
-
4daqsc208-209
2 Pages
-
usb-datasheet
14 Pages
-
NI_9478
4 Pages
-
NI_9472_Measurement_System
4 Pages
-
NI_9402_Measurement_System
4 Pages
-
NI_9263_Measurement_System
4 Pages
-
NI_9203_Measurement_System
4 Pages
-
NI_9208_Measurement_System
4 Pages
-
NI_9239_Measurement_
4 Pages
-
_Measurement_System
4 Pages
-
Measurement_System
4 Pages
-
_Measurement_
4 Pages
-
NI_cDAQ-9171
3 Pages
-
NI_cDAQ-9174
5 Pages
-
NI_cDAQ-9178
5 Pages
-
NI_cDAQ-9181
4 Pages
-
NI_cDAQ-9188
5 Pages
-
Wireless_Chassis
1 Pages
-
NI_cDAQ-9139
4 Pages
Archived catalogs
-
PXI Embedded Controllers
1 Pages
-
LabVIEW Real-Time Module
3 Pages
-
NI CompactDAQ Chassis
1 Pages