ds-37
14Pages

{{requestButtons}}

Catalog excerpts

ds-37 - 1

Technical Sales United States (866) 531-6285 info@ni.com Requirements and Compatibility | Ordering Information | Detailed Specifications | Pinouts/Front Panel Connections For user manuals and dimensional drawings, visit the product page resources tab on ni.com. Industrial M Series Multifunction DAQ – 16-Bit, ±10 V/±20 mA Analog I/O, 5 V/24 V Digital I/O Up to sixteen ±10 V or eight ±20 mA analog inputs at 16 bits, 250 kS/s Programmable input range (±10, ±5, ±1, ±0.2 V) per channel Up to four ±10 V or two 0 to 20 mA analog outputs at 16 bits, 500 kS/s (6 µs full-scale settling time) NI-MCal calibration technology for improved measurement accuracy 6 digital input and 4 digital output channels, 24 V (sourcing or sinking) or 5 V TTL/CMOS Two 32-bit, 80 MHz counter/timers 60 VDC continuous bank isolation, 1,400 Vrms/1,950 VDC channel-to-bus, isolation withstand for 5 s Per-channel selectable debounce filters for digital input lines and programmable power-up states for digital outputs Overview NI M Series industrial multifunction data acquisition (DAQ) devices combine the safety of isolation with the high-performance timing, amplification, and calibration methodologies unique to M Series devices to deliver accurate measurements and precise control. You can use industrial M Series devices for measurement, control, and design applications including measuring and controlling voltages and process currents from analog and digital sensors, transducers, relays, motors, valves, pumps, and other actuators. Back to Top Requirements and Compatibility OS Information Driver Information Software Compatibility Real-Time OS Windows 2000/XP Windows 7 Windows Vista x64/x86 ANSI C LabVIEW LabWindows/CVI Measurement Studio SignalExpress Visual Basic Visual Studio .NET Back to Top Comparison Tables NI Family NI 6230 Analog Input Channels Analog Output Channels 4 Digital Outputs Digital Voltage

Open the catalog to page 1
ds-37 - 2

Application and Technology Industrial Feature Set Industrial M Series multifunction DAQ devices offer a set of high-reliability features designed to automate even the most demanding applications. Isolation prevents ground loops, rejects high common-mode voltages, and protects users and equipment from high-voltage transients ±20 mA current inputs provide direct connectivity for 4 to 20 mA process current loops. Programmable digital debounce filters eliminate glitches/spikes and remove noise Change detection triggers on a digital event with minimal processor usage Sourcing or sinking digital...

Open the catalog to page 2
ds-37 - 3

Long cable lengths and the presence of electrical noise in industrial environments can make accurate voltage measurements difficult. As a result, industrial transducers that sense pressure, flow, proximity, and so on often emit current signals instead of voltage. Each of these current loops contains a power source, a transducer, and one or more data acquisition devices. The current signal is typically between 4 and 20 mA, with 0 mA indicating an open circuit; power supplies are typically in the range of 24 to 30 VDC. Because all the current that flows from one lead of the power supply must...

Open the catalog to page 3
ds-37 - 4

LabVIEW Professional Development System for Windows Advanced software tools for large project development Automatic code generation using DAQ Assistant and Instrument I/O Assistant Tight integration with a wide range of hardware Advanced measurement analysis and digital signal processing Open connectivity with DLLs, ActiveX, and .NET objects Capability to build DLLs, executables, and MSI installers Quickly configure projects without programming Control over 400 PC-based and stand-alone instruments Log data from more than 250 data acquisition devices Perform basic signal processing,...

Open the catalog to page 4
ds-37 - 5

NI offers design-in consulting and product integration assistance if you need NI products for OEM applications. For information about special pricing and services for OEM customers, visit ni.com/oem. Alliance Our Professional Services Team is comprised of NI applications engineers, NI Consulting Services, and a worldwide National Instruments Alliance Partner program of more than 700 independent consultants and integrators. Services range from start-up assistance to turnkey system integration. Visit ni.com/alliance. Back to Top Detailed Specifications Specifications listed below are typical...

Open the catalog to page 5
ds-37 - 6

Al <0..7> Small Signal Bandwidth Al *CMRR to Earth Ground

Open the catalog to page 6
ds-37 - 7

Positive Full Scale Negative Full Scale AbsoluteAccuracy = Reading · (GainError) + Range · (OffsetError) + NoiseUncertainty GainError = ResidualAIGainError + GainTempco · (TempChangeFromLastInternalCal) + ReferenceTempco · (TempChangeFromLastExternalCal) OffsetError = ResidualAIOffsetError + OffsetTempco · (TempChangeFromLastInternalCal) + INL_Error Absolute accuracy at full scale on the analog input channels is determined using the following assumptions: TempChangeFromLastExternalCal = 10 °C TempChangeFromLastInternalCal = 1 °C number_of_readings = 100 CoverageFactor = 3 σ For example, on...

Open the catalog to page 7
ds-37 - 8

Ground reference Input voltage range Minimum pulse width for timing signal Minimum input impedance Typical input current Maximum input current Propagation delay Low to high Digital Output (Port 1) Number of channels Ground reference Digital output type Refer to the NI 6238 Digital I/O Connections and the NI 6239 Digital I/O Connections figures. The NI 6238 Digital I/O Connections figure shows P0.<0..5> and P1.<0..3> on the NI 6238, and the NI 6239 Digital I/O Connections figure shows P0.<0..5> and P1.<0..3> on the NI 6239.

Open the catalog to page 8
ds-37 - 9

NI 6239 Digital I/O Connections Max external supply voltage (P1.VCC) On state saturation voltage Maximum current 100 mA for each line for simultaneous usage, 350 mA for single line usage Minimum pulse width for timing signal NI 6238 (source output) Propagation delay NI 6238 (source output) Open to close NI 6239 (sink output) Open to close General-Purpose Counter/Timers Number of counter/timers Counter measurements Edge counting, pulse, semi-period, period, two-edge separation Position measurements X1, X2, X4 quadrature encoding with Channel Z reloading; two-pulse encoding Output...

Open the catalog to page 9

All NATIONAL INSTRUMENTS catalogs and technical brochures

  1. NI 9381

    10 Pages

  2. NI 9402

    9 Pages

  3. BNC-2121

    3 Pages

  4. Counter/Timer

    10 Pages

  5. NI PXIe-6612

    12 Pages

  6. ds-392

    7 Pages

  7. ETC_196

    9 Pages

  8. ds-293

    13 Pages

  9. ds-353

    14 Pages

  10. ds-361

    5 Pages

  11. NI WSN-3202

    13 Pages

  12. cat_ni31xx

    5 Pages

  13. GPIB-USB-HS

    7 Pages

  14. Digital I/O,

    9 Pages

  15. NI PCIe-6321

    15 Pages

  16. NI USB-6509

    8 Pages

  17. NI_PCI-6713.

    5 Pages

  18. NI_PCIe-6363

    5 Pages

  19. NI_EVS-1464

    9 Pages

  20. ds-153

    18 Pages

  21. NI4065

    6 Pages

  22. 4daqsc253

    17 Pages

  23. NI_PCI-5122

    5 Pages

  24. NI_FPT-1015

    3 Pages

  25. NI_PXI-2501

    5 Pages

  26. cat_FET

    3 Pages

  27. 4daqsc253-265

    17 Pages

  28. usb-datasheet

    14 Pages

  29. NI_9478

    4 Pages

  30. NI_cDAQ-9171

    3 Pages

  31. NI_cDAQ-9174

    5 Pages

  32. NI_cDAQ-9178

    5 Pages

  33. NI_cDAQ-9181

    4 Pages

  34. NI_cDAQ-9188

    5 Pages

  35. NI_cDAQ-9139

    4 Pages

Archived catalogs