043918301101dlr

043918301101dlr

043918301101dlr

Product catalog summary
Overview and Applications
National Instruments 612x and 613x devices are designed for high-channel-count, high-speed applications with simultaneous sampling capabilities. They are ideal for applications such as IF digitization, transient recording, telecom manufacturing tests, ultrasound and sonar testing, and high-energy physics.
Features
These devices are part of the NI S Series, featuring simultaneous sampling with a dedicated A/D converter per channel. This setup enhances data throughput and dynamic specifications, offering multiple input ranges and large onboard memory. Key specifications include up to 16-bit resolution, up to 3 MS/s per channel, and up to 8 analog inputs.
Specifications
The NI 6123 and NI 6122 models offer 16-bit resolution with a maximum sampling rate of 500 kS/s per channel, while the NI 6133 and NI 6132 provide 14-bit resolution with up to 3 MS/s per channel. All models feature deep onboard memory (16 or 32 MS) and support digital and analog triggering.
Software and Compatibility
The devices are compatible with Windows 2000/NT/XP and are recommended for use with NI software such as LabVIEW, LabWindows/CVI, and Measurement Studio. They include the NI-DAQmx driver and other measurement services software to simplify configuration and data logging.
Toolkits and Add-ons
Several toolkits are available to enhance functionality, including the NI LabVIEW Sound and Vibration Toolkit, Signal Processing Toolkit, and Spectral Measurements Toolkit, providing advanced analysis and presentation capabilities.
Data Throughput and Transfer
Using NI-DAQmx, users can optimize data transfer and achieve high throughput rates. Data compaction features help improve stream-to-disk performance by reducing data size before recording.
Signal Conditioning
S Series devices are compatible with SCXI modules in parallel mode, allowing simultaneous sampling across channels with high sample rates.
Ordering Information
Various models are available for PCI and PXI buses, each with different memory configurations. For detailed specifications and pricing, users are directed to contact National Instruments or visit their website.
Additional Specifications
Counter/timers have a resolution of 24 bits, while the frequency scaler has a resolution of 4 bits. The system is compatible with TTL/CMOS. Base clocks available for counter/timers are 20 MHz and 100 kHz, and for the frequency scaler, they are 10 MHz and 100 kHz. The maximum source frequency is 20 MHz. Analog triggers can source from all analog input channels with a level of ± full-scale and a slope that is software selectable as positive or negative. The resolution is 8 bits, and hysteresis is programmable. Digital triggers are compatible with TTL and respond to rising or falling edges.
Cables and Accessories
Available accessories include the SH68-68-EP noise-rejecting shielded cable, R6868 low-cost ribbon cable, BNC-2110 noise-rejecting BNC I/O connector block, TB-2705 noise-rejecting front-mount I/O connector block, SCB-68 shielded I/O connector block with a general-purpose breadboard area, and CB-68LP and CB-68LPR low-cost I/O connector blocks with 68 screw terminals.
NI Services and Support
NI offers global services and support throughout the application life cycle, including training, professional services, OEM support, and local sales and technical support. Training and certification programs are available to enhance productivity with NI products. Professional services include start-up assistance and turnkey system integration. OEM support includes design-in consulting and product integration assistance. Local sales and technical support provide access to engineers and technical resources worldwide.
Hardware Services
NI Factory Installation Services (FIS) offer installation and configuration of PXI or PXI/SCXI systems. Calibration services ensure high-accuracy measurements with manual and automated calibration options. Repair and extended warranty services are available, including express repair and advance replacement services.
See more

Catalog excerpts

043918301101dlr-1

S Series Multifunction DAQ – up to 16-Bit, up to 3 MS/s per Channel, up to 8 Analog Inputs NI 6123, NI 6122, NI 6133, NI 6132 • 4 or 8 simultaneous-sampling differential analog inputs • 14- or 16-bit resolution • 3 MS/s1 or 500 kS/s per channel maximum sampling rate • 4 analog input ranges • Deep onboard memory – 16 or 32 MS • 8 digital I/O lines (5 V/TTL/CMOS); two 24-bit counter/timers • Digital and analog triggering • Measurement services that simplify configuration and measurements Operating Systems • Windows 2000/NT/XP Recommended NI Software • LabVIEW 7.x or higher • LabWindows/CVI 7.x or higher • Measurement Studio 7.x or higher • Digital Waveform Editor • SignalExpress 1.x or higher Other Compatible Software • VI Logger 2.x or higher • Visual Studio .NET • Visual Basic, C/C++, and C# Measurement Services Software (included) • NI-DAQmx driver • Measurement & Automation Explorer configuration utility • VI Logger Lite data-logging software Calibration Certificate Available Family NI 6123 NI 6122 NI 6133 NI 6132 12.5 Bus PCI, PXI PCI, PXI PCI, PXI PCI, PXI Analog Inputs 8 4 8 4 Input Resolution (bits) 16 16 14 14 Sampling Rate 500 kS/s per channel 500 kS/s per channel 3 MS/s per channel1 3 MS/s per channel1 Input Ranges 4 4 4 4 Digital I/O 8 @ 10 MHz 8 @ 10 MHz 8 @ 10 MHz 8 @ 10 MHz Counter/Timers 2, 24-bit 2, 24-bit 2, 24-bit 2, 24-bit Trigger Analog, digital Analog, digital Analog, digital Analog, digital MS/s with NI-DAQmx; 3 MS/s with additional download. Special conditions apply. Table 1. Channel, Speed, and Resolution Specifications Overview and Applications National Instruments 612x and 613x devices combine the latest in PC technologies to deliver simultaneous sampling for high-channelcount, high-speed applications. Use these modules in a variety of applications, including: • IF digitization • Transient recording • ISDN, ADSL, and POTS manufacturing test in the telecom industry • Ultrasound and sonar testing • High-energy physics constant, regardless of the number of active channels. S Series aggregate data throughput increases linearly with the number of active channels. Better Dynamic Specifications – The analog input path on S Series devices is tuned for both accurate DC and dynamic measurements, compared to traditional multiplexed data acquisition devices that suffer from settling time and distortion error created by switching the input channel. Traditional multiplexed data acquisition devices are ideal for DC measurements, but are not the best solution for dynamic measurements. Features These devices fall under the NI S Series product family. The “S” stands for simultaneous sampling, as this is the most apparent benefit of the dedicated analog-to-digital (A/D) converter per channel architecture. However, the architecture has other less obvious but very important advantages. More Data Throughput – The dedicated A/D converter per channel architecture provides a much higher aggregate sampling rate compared to traditional multiplexed data acquisition devices. Traditional multiplexed data acquisition devices share one A/D converter among multiple channels, keeping the aggregate data throughput Many Input Ranges – You can configure each analog input channel to use one of several voltage ranges. Make the most of your input resolution by selecting among the four voltage ranges offered by the NI 612x and 613x devices. Large Onboard Memory – NI 6123 and NI 6133 devices feature a 16 or 32 MS onboard memory while the NI 6122 and NI 6132 devices feature a 16 MS memory. With deep onboard memory, capture highbandwidth signals over long periods of time, regardless of bus limitations.

 Open the catalog to page 1
043918301101dlr-2

S Series Multifunction DAQ – up to 16-Bit, up to 3 MS/s per Channel, up to 8 Analog Inputs Professional Analysis and Presentation Toolkits There are several analysis and presentation add-on toolkits available from National Instruments that help make you more productive when developing custom applications with your S Series devices. Turn your S Series device into a transient recorder, spectrum analyzer, or one of several other instruments with these toolkits. NI LabVIEW Sound and Vibration Toolkit This toolkit includes a full set of frequency-domain analysis and presentation tools required for...

 Open the catalog to page 2
043918301101dlr-4

S Series Multifunction DAQ – up to 16-Bit, up to 3 MS/s per Channel, up to 8 Analog Inputs CAL Mux Address/Data DustMITE PGIA AI 0 16-Bit ADC Control AI 0 Channel Control 0 PGIA AI 1 16-Bit ADC Data (32) Config EEPROM AI 1 Address (32) Channel Control 1 SCARAB AI 2 Cal EEPROM Channel Control 2 I/O Connector PGIA AI 3 16-Bit ADC FPGA Channel Control 3 PGIA AI 4 16-Bit ADC AI Control AI 3 AI 4 STCA Channel Control 4 AI 5 16-Bit ADC DMA/IRQ AI 5 CPLD Trigger Analog Input Timing/ Control DMA/IRQ Counter/ Timing I/O DAQSTC Bus Interface Digital I/O PGIA Analog Output Timing/ Control Channel Control...

 Open the catalog to page 4
043918301101dlr-7

NI Services and Support NI has the services and support to meet your needs around the globe and through the application life cycle – from planning and development through deployment and ongoing maintenance. We offer services and service levels to meet customer requirements in research, design, validation, and manufacturing. Visit ni.com/services. Local Sales and Technical Support SERVICE NEEDS In offices worldwide, our staff is local to the country, giving you access to engineers who speak your language. NI delivers industryleading technical support through online knowledge bases, our applications...

 Open the catalog to page 7

All NATIONAL INSTRUMENTS catalogs and technical brochures

  1. NI 9381

    10  Pages

  2. NI 9402

    9  Pages

  3. NI PXIe-6612

    12  Pages

  4. ds-392

    7  Pages

  5. ETC_196

    9  Pages

  6. ds-293

    13  Pages

  7. ds-353

    14  Pages

  8. ds-361

    5  Pages

  9. NI WSN-3202

    13  Pages

  10. cat_ni31xx

    5  Pages

  11. GPIB-USB-HS

    7  Pages

  12. Digital I/O,

    9  Pages

  13. NI PCIe-6321

    15  Pages

  14. NI USB-6509

    8  Pages

  15. NI_PCI-6713.

    5  Pages

  16. NI_PCIe-6363

    5  Pages

  17. NI_EVS-1464

    9  Pages

  18. ds-153

    18  Pages

  19. ds-37

    14  Pages

  20. NI4065

    6  Pages

  21. 4daqsc253

    17  Pages

  22. NI_PCI-5122

    5  Pages

  23. NI_FPT-1015

    3  Pages

  24. NI_PXI-2501

    5  Pages

  25. cat_FET

    3  Pages

  26. cat_evs1464RT

    9  Pages

  27. 4daqsc253-265

    17  Pages

  28. 4daqsc208-209

    2  Pages

  29. usb-datasheet

    14  Pages

  30. NI_9478

    4  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.