Catalog excerpts
9010F FTT Time Domain Digital EMI Receiver & Real Time Analyzer • FFT-based, gapless EMI receiver & Analyzer, 10 Hz – 30 MHz • Full compliance to CISPR 16-1-1 • Reduces test time from hours to seconds • Real-time spectrum analysis • Rugged, light weight, small size, internal battery for best portability • User-friendly in stand-alone and with the powerful PMM Emission Suite • Expandable to higher frequencies
Open the catalog to page 1Measurement of conducted and radiated emissions of EUT in full compliance to CISPR, IEC-EN standards. Analyzing the emissions in short time is particularly suitable for EUT with short operation cycles, e.g. electric tools, food machinery and in general all appliances with electric motors subjected to over-heating if run for too long time. Fast and reliable tests provide the designer of an immediate feedback in the try-and-test process, an effective contribution to reduce the product time-to-market. The new EMI Receiver 9010F is based on very advanced analog to digital conversion and data...
Open the catalog to page 2SPECIFICATIONS Frequency range Resolution Frequency accuracy RF input VSWR 10 dB RF att. 0 dB RF att. Attenuator Preamplifier Gain Pulse limiter Zin 50 Ω, N fem. < 1.2 < 1.6 0 dB to 35 dB (5dB steps) 20 dB (after preselector) Built in (selectable) Max input level (without equipment damage) Sinewave AC voltage Pulse spectral density Noise level @ hold time 1s Quasi-peak (dBμV) Average (dBμV) Spurious response Peak, Hold time 100 ms Peak, Quasi-Peak, Avarage, RMS, RMS-Avarage, C-Avarage, APD Scan time SWEEP MODE FUll CISPR: preselector ON, QP detector Hold time 1 s, 200 Hz RBW Hold time 1 s,...
Open the catalog to page 3Ordering Information - PC software PMM Emission Suite - Standard Calibration Certificate ■ Contro, cable (USB, RS-232), BNC-BNC cable Optional Accessories and functions SjlesOifice: ^^^l k ■ / Safety Test Solutions Headquarter: Via Leonardo da Vinci, 21/23 ™ 1 K-^Tf =" (^communications company ViaBenessea, 29/B 20090 Segrate (Milano) - ITALY a Drana OT 17035 Cisano sul Neva (SV) - ITALY
Open the catalog to page 4All Narda Safety Test Solutions GmbH catalogs and technical brochures
-
Datasheet_EF6092
2 Pages
-
NIM-511/513
4 Pages
-
NBM-580
4 Pages
-
Narda EMF Monitors
8 Pages
-
NRA-RX Narda Remote Analyzer
12 Pages
-
Area monitoring
16 Pages
-
HUMAN SAFETY
8 Pages
-
EHP-200A
7 Pages
-
THM 1176
6 Pages
-
NRA-2500, NRA-3000 and NRA-6000
11 Pages
-
L3-500 3-phase LISN
2 Pages
-
L3-100 3-phase LISN
2 Pages
-
L3-64 3-phase LISN
2 Pages
-
L3-32 3-phase LISN
2 Pages
-
L1-500 Single-path LISN
2 Pages
-
7010 All-in-one EMI Receiver
2 Pages
-
SRM-3006
24 Pages
-
EFC-400LF
6 Pages
-
EHP-50D
12 Pages
-
ELT-400
8 Pages
-
EFA-300
10 Pages
-
RadMan XT
5 Pages
Archived catalogs
-
SMARTS II
4 Pages
-
Narda Area Monitor AMS 8060
5 Pages
-
Narda Area Monitor AMB 8057
8 Pages
-
Nardalert XT
6 Pages
-
Data sheet NBM-520
7 Pages
-
EHP-200
7 Pages
-
EHP-50
9 Pages
-
THM1176-PDA
6 Pages
-
Simulation Software EFC-400
2 Pages
-
ELECTROMAGNETIC FIELDS
12 Pages
-
EFA-200/300 Low Frequency
16 Pages