ELT-400 - 1

EXPOSURE LEVEL TESTER ELT-400 Safety Evaluation Within a Magnetic Field Environment Direct evaluation of field exposure in comparison with major standards Automatic exposure evaluation for various waveforms Eliminates the overestimation that occasionally occurs with FFT-based evaluation Ultra wide frequency range (1 Hz to 400 kHz) Wide measurement range (up to 80 mT, dependent on type) IEC 62233, EN 62233, EN 50366 : 2003 and A1 2006 standard compliant isotropic including 100 cm² probe and 3 cm² probe Three-axis analog signal output Exposure Level Tester ELT-400 Subject to change without notice

Open the catalog to page 1
ELT-400 - 2

APPLICATIONS The ELT-400 is an innovative exposure level meter for measuring magnetic fields in the workplace and in public spaces. The model is designed for health and safety professionals in industry, the insurance business and service industries. The instrument can simply and precisely handle practically any level measurement required in the low and medium-frequency range. It is comparable to the sound level meters that are commonly used in the assessment of noise at the workplace. Production Areas The ELT-400 is useful for checking fields caused by various manufacturing plant, including...

Open the catalog to page 2
ELT-400 - 3

and speed and ease of use are significantly better than all traditional methods. BASIC OPERATION The ELT-400 covers the wide frequency range of 1 Hz to 400 kHz. The measurement range of the ELT-400 is far wider than the reference limits of common guidelines. The instrument has an external isotropic 2 magnetic field probe with a 100 cm cross-sectional area. This is suitable for standards-compliant measurement even in nonhomogeneous fields. The ELT-400 has a rugged housing and is easy to operate using only six buttons. The measurement result and the instrument settings are clearly displayed...

Open the catalog to page 3
ELT-400 - 4

STD mode. This completely eliminates the need to analyze the waveform in the time domain using a scope. Even when faced with pulses that include DC fields, the EXPOSURE STD method provides valuable results. The ELT-400 covers all the signal components down to 1 Hz that are relevant in assessing such a situation. Occasionally both the RMS value and the peak value are critical for assessing exposure in the low-frequency range. Both detector types are provided, and are simultaneously activated in the default setting. Depending on the incoming signal and standard selected, the most suitable...

Open the catalog to page 4
ELT-400 - 5

ACTIVE FIELD PROBE Three-Axis Analogue Signal Output For scientific studies or advanced signal-shape / frequency analysis, a scope or an FFT analyzer can be connected to the analogue output. The output signal ensures proper phase within the three axes and covers the full bandwidth of the instrument. The buffered output provides an adequate voltage swing to allow for simple operation. Subject to change without notice

Open the catalog to page 5
ELT-400 - 6

SPECIFICATIONS a ELT – 400 with 100 cm2 probe Frequency range (-3 dB), selectable Antenna type Sensor type RMS Damage level Peak Measurement uncertainty E-Field response Mounting thread EXPOSURE STD MODE Exposure evaluation b MODE RANGE Overload limit c Noise level, typical Resolution Detection, selectable Display mode, selectable FIELD STRENGTH MODE Frequency response b MODE RANGE Overload limit e Noise level, typical Resolution Detection, selectable Display mode, selectable OUTPUT Analogue scope output Analogue output level Interface (remote control and readout) GENERAL SPECIFICATIONS...

Open the catalog to page 6
ELT-400 - 7

ELT – 400 with 3 cm2 probe Frequency range (-3 dB), selectable Antenna type Sensor type RMS Damage level Peak Measurement uncertainty E-Field response Mounting thread EXPOSURE STD MODE Exposure evaluation b MODE RANGE Overload limit c Noise level , typical Resolution Detection, selectable Display mode, selectable FIELD STRENGTH MODE Frequency range b MODE RANGE Overload limit e Noise level, typical Resolution Detection, selectable Display mode, selectable OUTPUT Analogue scope output Analogue output level Interface (remote control and readout) GENERAL SPECIFICATIONS Operating temperature...

Open the catalog to page 7
ELT-400 - 8

ORDERING INFORMATION ELT-400 Exposure Level Tester Calibrated Basic Unit and B-field probe (100 cm²), with calibration certificate, charger unit (fits all AC line connectors), operating / programming manual, and rechargeable batteries MODES (included in instrument) • EXPOSURE STD: ICNIRP gen. pub. 1998 • FIELDSTRENGTH: 320 µT Set 1 2304/101 • EXPOSURE STD: ICNIRP OCC. 1998 • FIELDSTRENGTH: 80 mT • EXPOSURE STD: BGV B11 EXP2 • EXPOSURE STD: BGV B11 2H/D Set 2 2304/102 • EXPOSURE STD: BGV B11 EXP1 • FIELDSTRENGTH: 8 mT • EXPOSURE STD: IEC/EN 62233 • FIELDSTRENGTH: 320 µT Set 4 2304/104 •...

Open the catalog to page 8

All Narda Safety Test Solutions GmbH catalogs and technical brochures

  1. NIM-511/513

    4 Pages

  2. NBM-580

    4 Pages

  3. HUMAN SAFETY

    8 Pages

  4. EHP-200A

    7 Pages

  5. THM 1176

    6 Pages

  6. SRM-3006

    24 Pages

  7. EFC-400LF

    6 Pages

  8. EHP-50D

    12 Pages

  9. EFA-300

    10 Pages

  10. RadMan XT

    5 Pages

Archived catalogs

  1. SMARTS II

    4 Pages

  2. Nardalert XT

    6 Pages

  3. EHP-200

    7 Pages

  4. EHP-50

    9 Pages

  5. THM1176-PDA

    6 Pages