1/8 Subject to change without notice Selective and broadband low frequency field analysis Electric and magnetic low frequency field analysis up to 100 kHz Isotropic measurement with a dynamic range of 140 dB Small size and optical fibre connection for spot measurement Built-in FFT spectrum analysis Wideband mode Built-in rechargeable battery with great autonomy Interface to 8053-Display and PC EHP-50C www.narda-sts.com ELECTRIC AND MAGNETIC FIELD ANALYZER EHP-50C 09-09 - EHP-50C
Open the catalog to page 109-09 - EHP-50C 2/8 Subject to change without notice Electrosmog is a popular term used to describe any phenomenon or problem associated with artificially generated electric or magnetic fields. A range of electric or electronic devices may cause an environmental risk and – under certain conditions - generate potentially hazardous electric or magnetic fields; however, special attention is devoted to low frequency fields, such as those generated by power transmission lines, traction lines and, in general, high current equipment (large electric motors, huge manufacturing machines, power generators,...
Open the catalog to page 209-09 - EHP-50C 3/8 Subject to change without notice Stand-alone continuous acquisition with internal data logger for 24 hours When a long monitoring campaign is a must – e.g. when measuring magnetic fields next to high, medium and low voltage transformers; measuring close to power lines or to machinery, air conditioning systems, large home appliances, etc. - the EHP-50C can be used in stand-alone mode without needing a PC or an 8053-Display connected to it. Once the measurement parameters have been programmed, through the PC software (supplied), the EHP-50C analyser can start acquisition by...
Open the catalog to page 309-09 - EHP-50C 4/8 Subject to change without notice The EHP-50C has an efficient battery management system enabling operations in Logger mode for a very long time (see the table, right). During the time the Data Logger - Low Power is operated, the Analyser takes a measurement and transfers it to the internal non volatile memory of the 8053-Display, after which it goes into a state of low consumption until the next measurement is started. The time interval between measurements can be set from 10 to 900 seconds (15 minutes). 8053-Display Logger Interface To enhance the monitoring capacity of the...
Open the catalog to page 409-09 - EHP-50C 5/8 Subject to change without notice The recently developed EHP-TS software allows the user to control Narda analyzers such as EHP-50C and EHP-200 through a Personal Computer. The optical cable coming from the analyzer (Max lenght: 40m) can be easily connected to the PC by the optical to USB converter USB-OC provided if longer distance is required the optional 8053-OC optical to RS232 converter can be used for optical fibre length up to 80m.. A user friendly graphical interface includes commands to set all parameters. To understand them better, controls are grouped in five selectable...
Open the catalog to page 509-09 - EHP-50C 6/8 Subject to change without notice EHP-50C Specifications Functional Specifications Electric Field Magnetic Field Frequency range 5 Hz /100 kHz Measuring Ranges 1 kV/m / 100 kV/m 0.1 mT / 10 mT Overload 200 kV/m @ 50 Hz 20 mT @ 50 Hz Resolution 0,001 V/m on 8053-Display and in "Stand Alone" mode 1 nT on 8053-Display and in "Stand Alone" mode 0,1 V/m with 8053-Display data logger 10 nT with 8053-Display data logger Sensitivity 0.01 V/m 1 nT Flatness (40 Hz – 10 kHz) ±0.5 dB ±0.5 dB Typical 3D anisotropy 6.5% (0,54dB) 1.4% (0.12dB) Linearity @ 50 Hz ±0.2 dB (1 V/m ÷ 100 kV/m)...
Open the catalog to page 6EHP-50C Specifications General Specifications Calibration Internal EEPROM Temperature Error (referred to 23°C) ±0.05 dB/°C between -10 and +23°C @40% RH ±0.01 dB/°C between +23 and +50°C @40% RH Humidity Error (referred to 40%) ±0.05 dB between 20% and 50% @+23°C ±0.05 dB between 50% and 80% @+23°C Internal Battery Rechargeable NiMH batteries (5 x 1,2 V) Operating Time > 10 hours in normal mode > 150 hours in low power mode 24 hours with internal data logger in stand alone mode Recharging Time < 4 hours External DC supply 10 / 15 V, about 200 mA Optical Fibre Link and operating distance Up to...
Open the catalog to page 709-09 - EHP-50C 7/8 Subject to change without notice ORDERING INFORMATION www.narda-sts.com 8053-Display Unit Specifications Functional Specifications Electric Field Magnetic Field Display Backlight LCD, 72 x 72 mm, 128 x 128 pixels Interfaces Optical Fibre; RS-232 Internal memory 32700 measurements Functions RMS/AVG, 30 s up to 30 min.; alarm 0-100 % f.sc. Data logger modes Sampling (1, 10 to 900 s); data change; over limit; manual; Clock Internal real time clock Internal battery Rechargeable NiMH batteries (5 x 1.2 V) External DC supply 10 / 15 V, about 500 mA Operational and Storage temperature...
Open the catalog to page 809-09 - EHP-50C 8/8 Subject to change without notice www.narda-sts.com Narda Safety Test Solutions GmbH Sandwiesenstrasse 7 72793 Pfullingen, Germany Phone: +49 (0) 7121-97 32-777 Fax: +49 (0) 7121-97 32-790 E-Mail: [email protected] www.narda-sts.de Narda Safety Test Solutions 435 Moreland Road Hauppauge, NY 11788, USA Phone: +1 631 231-1700 Fax: +1 631 231-1711 E-Mail: [email protected] www.narda-sts.com Narda Safety Test Solutions srl Via Leonardo da Vinci, 21/23 20090 Segrate (MI) ITALY Phone: +39 02 26.998.71 Fax: +39 02 26.998.700 E-Mail: [email protected] www.narda-sts.it
Open the catalog to page 92 Pages
4 Pages
4 Pages
8 Pages
12 Pages
16 Pages
8 Pages
7 Pages
6 Pages
11 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
24 Pages
6 Pages
12 Pages
8 Pages
10 Pages
5 Pages
4 Pages
5 Pages
8 Pages
6 Pages
7 Pages
7 Pages
6 Pages
2 Pages
12 Pages
16 Pages