EHP-200A - 1

ELECTRIC AND MAGNETIC FIELD ANALYZER EHP-200A Selective and broadband high frequency field analysis New solution for isotropic measurements in the 9 kHz – 30 MHz range Electric Fields from 0.02 to 1000 V/m Magnetic Fields from 0.6 mA/m to 300 A/m Built-in Frequency Spectrum Analysis Built-in rechargeable Li-Ion battery Optical Fibre connection to PC Subject to change without notice

Open the catalog to page 1
EHP-200A - 2

EHP200A E&H FIELD ANALYZER The E-H field analyser mod. EHP-200A was designed for accurate isotropic measurements of both electric and magnetic fields in the 9 kHz - 30 MHz frequency range, with no or minimum perturbation of the fields to be measured. Field sensors and electronic measuring circuitry are fitted into robust housing, only 92 x 92 x 109 mm in size. Separate 3 axis and total values (actual and average) are measured with exceptional flatness and linearity of 0.5 dB. Results are expressed in V/m, A/m, μT, mW/cm2, mG, W/m2, Ohm, % (percentage of the selected Limit). When the...

Open the catalog to page 2
EHP-200A - 3

Safety Test Solutions EHP-TS application software The recently developed EHP-TS software allows the user to control Narda analyzers such as EHP-50C and EHP-200 through a Personal Computer. The optical cable coming from the analyzer (Max lenght: 40m) can be easi- ly connected to the PC by the provided optical to USB converter USB-OC. If longer distance is required the optional 8053-OC optical to RS232 con- verter can be used for optical fibre length up to 80m. A user friendly graphical interface includes commands to set all parame- To understand them better, controls are grouped in five...

Open the catalog to page 3
EHP-200A - 4

Safety Test Solutions The EHP-200 can also be easily operated through the accessory 8053-Display Unit, with the following limitations: • no wave impedance computing Span setting: The following functions are available: Field selection (E, H), 3-axis display, Min-Max-RMS, Logger, Alarms. By the Data logger mode of the 8053-Display Unit, the User can record the measurements and save them in a file in the memory of the 8053- Display Unit. All collected data files are progressively numbered and contain: • Time duration • Logger settings • Date and time when the measurement began • Average value...

Open the catalog to page 4
EHP-200A - 5

TECHNICAL SPECIFICATIONS EHP-200A E&H FIELD ANALYSER RF Specifications Frequency Range Measurement Range Dynamic range Sensitivity Resolution Flatness Anisotropy Linearity Frequency span width Resolution bandwidth Rejection to E- Field Rejection to H- Field Calibration Temperature error General Specifications AUX input Preamplifier Reading Units Optical link Internal battery Battery operation External supply Firmware update Operating temperature Storage temperature Dimensions and weight Recommended calibration interval Country of origin Electric Field Magnetic Field Magnetic Field AUX Input...

Open the catalog to page 5
EHP-200A - 6

Safety Test Solutions Subject to change without notice

Open the catalog to page 6
EHP-200A - 7

Safety Test Solutions Narda Safety Test Solutions GmbH E-Mail: support@narda-sts.de Narda Safety Test Solutions Narda Safety Test Solutions Sri E-Mail: support@narda-sts.it Subject to change without notice

Open the catalog to page 7

All Narda Safety Test Solutions GmbH catalogs and technical brochures

  1. NIM-511/513

    4 Pages

  2. NBM-580

    4 Pages

  3. HUMAN SAFETY

    8 Pages

  4. THM 1176

    6 Pages

  5. SRM-3006

    24 Pages

  6. EFC-400LF

    6 Pages

  7. EHP-50D

    12 Pages

  8. ELT-400

    8 Pages

  9. EFA-300

    10 Pages

  10. RadMan XT

    5 Pages

Archived catalogs

  1. SMARTS II

    4 Pages

  2. Nardalert XT

    6 Pages

  3. EHP-200

    7 Pages

  4. EHP-50

    9 Pages

  5. THM1176-PDA

    6 Pages