EFA-300
1 /10Pages

EFA-300

EFA-300
1 /10Pages

Catalog excerpts

EFA-300-1

For Isotropic Measurement of Magnetic and Electric Fields Evaluation of Field Exposure compared to Major Standards and Guidance (selectable) Shaped Time Domain (STD) – an innovative technique for signal-shape-independent field measurements Fast Fourier Transform (FFT) Spectral Analysis Peak Value Measurement with Proper Phase Large-Capacity Data Storage Remote Control Frequency Range 5 Hz to 32 kHz Subject to change without notice

 Open the catalog to page 1
EFA-300-2

APPLICATIONS The EFA-300 is the ideal field analyzer for measuring magnetic and electric fields in the workplace and in public spaces. The unit is designed for professional users in the power industry, at municipal utilities, by insurers, and for health and safety professionals in industry. In the low frequency range, they handle any measurement, simply and precisely. This instrument provides field analysis using an FFT computation in addition to measuring magnetic and electric fields. The innovative STD mode opens up further application areas. With this new mode the measurement results for magnetic...

 Open the catalog to page 2
EFA-300-3

/ Safety Test Solutions Various standards and guidance take into account the fact that signal shape plays a major role in determining the workplace limit. For example, in Germany the employer's liability insurance association guideline on "Electromagnetic Fields" specifies different evaluation guidelines for different field shapes. Stationary sinusoidal and pulsed fields are differentiated. Occasionally both the RMS value and the peak value, (with proper phase) are critical for assessing exposure in the low- frequency range. The aim of this new generation of equipment is to greatly simplify the...

 Open the catalog to page 3
EFA-300-4

In broadband mode, the large, backlit display provides measurement and frequency results simultaneously. Two plug-in B-field probes extend the range of possibilities. The small "sniffer" probe has a 3 cm diameter while the larger, more sensitive probe, has a 100 cm2 cross-sectional area. Users can choose between RMS and peak value measurement from less than 1 nT to 31.6 mT. The EFA-300 can also measure the E-field from less than 1 V/m to 100 kV/m. STD (Shaped Time Domain) EVALUATION MODE Innovative Technique for Signal-Shape-Independent Field Measurements In many situations, detailed knowledge...

 Open the catalog to page 4
EFA-300-5

Safety Test Solutions Spectrum analysis considerably simplifies the process of quickly evaluating multi-frequency signals up to 32 kHz. All spectral components are evaluated at once. To provide a spectrum, the signal curve versus time is recorded via the probe and converted into the frequency domain using a mathematical procedure known as "Fast Fourier Transform". The EFA-300 is so powerful that even transient events ranging up to 2 kHz can be analyzed in real time. Evaluation is supported by graphics to clearly show the frequency spectrum and by cursor functions with frequency and level indications....

 Open the catalog to page 5
EFA-300-6

REMOTE AND DATA ANALYSIS SOFTWARE EFA-TS This optional software is used to: • • • • Provide remote control of the field analyzer and data readout Download the data stored in the device Save acquired data on the computer Analyze the data and provide a graphic representation of the results to support the user in the preparation of measurement reports Features • Windows interface to configure the instrument and/or to control it remotely. • Graphic representation of data stored in the internal memory of the instrument or in a file: o Line diagrams show field strength or Percent of Standard versus...

 Open the catalog to page 6
EFA-300-7

SPECIFICATIONS EFA-300 Magnetic (B-) Field 100 cm² Probe Sensor System Measurement Axis, selectable FIELD STRENGTH MODE Broadband (+0/-3 dB), selectable Frequency Range Band Pass / Band Reject Filter, adjustable Noise level (RSM), typical Coil (internal or external) Tri- Axial (Isotropic) or Single Axis Plate Electrode Damage Level (Peak) Damage Level (Peak) Electric (E-) Field 3 cm Probe RMS (averaging time 1 sec.) Peak Value (proper phase) Detection, selectable Measurement Range Internal Probe Damage Level (Peak) For magnetic field probes depending on frequency Broadband, 30 Hz to 2 kHz Broadband,...

 Open the catalog to page 7
EFA-300-8

Magnetic (B-) Field 100 cm² Probe EXPOSURE STD MODE Frequency Range (+0/-3 dB) Exposure Evaluation Measurement Range / Overload Limit 200% d Noise Level, typical <0.4% (for ICNIRP Occupational) b Uncertainty, typical (percent of reading) ±4% SPECTRUM FFT / HARMONICS MODE (Optional) Frequency Range Fundamental Range (HARMONICS only) Resolution by 2 kHz Range Marker: 32 kHz Range Frequency 2 kHz Range Scale, 32 kHz Range selectable: Detection, selectable Internal Probe Electric (E-) Field 3 cm Probe 5Hz to 32 kHz c Compared to Standards Stored in Meter 200% 200% 5 Hz to 2kHz 40 Hz to 32 kHz 10...

 Open the catalog to page 8
EFA-300-9

GENERAL SPECIFICATIONS Display Alarm, Adjustable Threshold Current Documentation (Specific Modes Only) Interface (Remote Control, Data Memory) Operating Temperature Range Humidity Operating Continuous Interval, typical Measurement Programmed Sequence Time Calibration Interval, recommended Battery LCD Dot Matrix 128x64 Pixel with Backlight Via B-Field Unit Acoustical, Optical Via B-Field Unit Input of Prevailing and Reference Current Value; N/A Storage with Measurement Value of Field Optical, Serial (RS-232) 0°C to +50°C <95 % or <29 g/m³ Occasional Brief Condensation Tolerable 10 Hours 24 Hours...

 Open the catalog to page 9
EFA-300-10

ORDERING INFORMATION EFA-300 Electric and Magnetic Field Analyzer Part number - Basic Unit (EFA-300, EM Field Analyzer System, 5 Hz-32kHz), Calibrated - Mode: FIELD STRENGTH, EXPOSURE STD, HARMONIC ANALYSIS - Hard case for EFA-300 - O/E Converter ORSD-9 Universal - Cable, Fiber Optic Duplex (1000µm), 2m - Software, EFA-200/-300 Tools - Power Supply 9VDC, 100V-240VAC, all Plugs - Operating Manual EFA-200/-300, English or German Probe, Electric Field for EFA-300 - E-Field-Probe 5 Hz-32 kHz for EFA-300, Calibrated - Power Supply 9VDC, 100V-240VAC, all Plugs - Cable, Fiber Optic Duplex (1000µm),...

 Open the catalog to page 10
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.