Nanosurf Flex-ANA - 1

AFM for automated nanomechanical analysis Real-time, automated data collection and analysis Next-Level Nanotechnology Tools Ability to cope with large variations in sample height Ideal for nanomechanical testing of soft, rough, and sticky samples info@nanosurf.com / www.nanosurf.com swiss quality

Open the catalog to page 1
Nanosurf Flex-ANA - 2

Flex-ANA Flex-ANA workflow: Multiple samples, each with easily defined measurement locations Automated nanomechanical data acquisition and analysis The Nanosurf Flex-ANA system is an automated solution for AFM-based nanomechanical analysis. It is designed to investigate the nanomechanical properties of materials such as cells, tissues, scaffolds, hydrogels, and polymers on multiple or large samples in an easy-to-use fashion. Key Software Features •• Straight-forward experimental workflow Single modulus maps from all selected locations Only a few steps from sample mounting to results ••...

Open the catalog to page 2
Nanosurf Flex-ANA - 3

uncoated coating 1 coating 2 Polymeric coatings on medical tubing •• uning surface coatings for improved biocompatibility T •• Biocompatibility is crucial for many devices and consumables used in modern medicine, i.e. surfaces must be compatible with the tissue they interact with •• Polymer properties can be tailored to meet the requirements of the application, e.g. drug release or minimized blood coagulation and foreign body response •• Coated medical tubing analyzed with Flex-ANA •• The nanomechanical properties of uncoated and two differently coated tubings were investigated using...

Open the catalog to page 3
Nanosurf Flex-ANA - 4

Flex-ANA system workflow FlexAFM scan head specifications Mounting and calibrating the cantilever Automated measurement and calculation of deflection sensitivity and spring constant Laser class (wavelength) Spring constant calibration based on the Sader Method Maximum Petri dish height (fluid level) Resonance frequency and Q-factor extraction from thermal noise power spectrum Automatic approach range Maximum XY-scan range Maximum Z-range Sample loading and overview image Overview image covering up to 80 mm × 60 mm Definition of measurement locations and conditions Measurement locations can...

Open the catalog to page 4