Catalog excerpts

Calibration is a Comparison between the reading of a Device (Unit under Test) and that of a Standard. The process which establishes this relationship is a set of interrelated measurements and set of operations which provide the Comparison. After flow meters are manufactured / procured, they need to be calibrated before being sent out into the field. Most flow meter manufacturers have their own flow meter calibration facilities for performing this initial calibration. Calibration of flow meters enables us to optimize their utility, with the result that the Uncertainty between the actual...
Open the catalog to page 2
PROCESS FLOW METER CALIBRATION SYSTEM FLOCAL SERIES Flow meter measures the rate of flow of fluid which passes through it. Flow meters are used in wide variety of applications where accurate flow measurements are critical in various sectors like Energy, Power, Refineries, Utilities, Water Management, Aerospace, Pharmaceutical Industry etc. In critical applications like these, it's important to Calibrate the Flow Meters to enable make reliable measurements. Regular Calibrations assure you that the Flow Meter's Measurements are as accurate as their specifications. Even the most rugged Flow...
Open the catalog to page 3
3D VIEW OF FLOCAL SYSTEM COMPARISON METHOD
Open the catalog to page 4
Specifications / Features 'PROCESS' FLOW METER CALIBRATION SYSTEM Nofe: Gravimetric Calibration can be performed up to 6,000 Liters volume on the basis of 1 minute (60 Seconds) campaign (i.e. Flow rate 6000 LPM). For volume higher than 6,000 Liters (for e.g. flow rates higher than 6,000 liters I minute) Gravimetric Calibration Campaign time will be varied according to the set flow rate.
Open the catalog to page 5
3D VIEW OF FLOCAL SYSTEM AUTOMATIC SYSTEM
Open the catalog to page 6
Specifications / Features 'PROCESS' FLOW METER CALIBRATION SYSTEM Nofe: Gravimetric Calibration can be performed up to 12,000 Liters volume on the basis of 1 minute (60 Seconds) campaign (i.e. Flow rate 12000 LPM). For volume higher than 12,000 Liters (for e.g. flow rates higher than 12,000 liters I minute) Gravimetric Calibration Campaign time will be varied according to the
Open the catalog to page 7
WATER METER CALIBRATION TEST BENCH SYSTEM WATCAL SERIES It is every one's responsibility to save water, which is a precious commodity. After all, out of 100% of the Worlds' Water resource, only 3% of the water is usable, this imposes moral responsibility to precisely use this natural & scarce resource. Nag man Designed & introduced 'WATCAL' - Water Meter Calibration Systems, for Calibrating the Accuracy of: Domestic Water Meters, typically in sizes Industrial / Bulk Water Meters, typically in sizes In accordance with the Standard ISO4064/3, BIS 779 Domestic Water Meters and Bulk Water...
Open the catalog to page 8
3D VIEW OF WATCAL SYSTEM COMPARISON METHOD
Open the catalog to page 10
Specifications / Features WATER METER CALIBRATION TEST BENCH SYSTEM
Open the catalog to page 11
Specifications / Features WATER METER CALIBRATION TEST BENCH SYSTEM
Open the catalog to page 13
3D VIEW OF WATCAL SYSTEM VOLUMETRIC METHOD
Open the catalog to page 14
Specifications / Features WATER METER CALIBRATION TEST BENCH SYSTEM
Open the catalog to page 15
3D VIEW OF WATCAL SYSTEM
Open the catalog to page 16
Specifications / Features WATER METER CALIBRATION TEST BENCH SYSTEM
Open the catalog to page 17
WATER METER CALIBRATION TEST BENCH SYSTEM WATCAL 50300 SERIES (Contd.) Gravimetric Calibration can be performed up to 12,000 Liters volume on the basis of 1 minute (60 Seconds) campaign (i.e. Flow rate 12000 LPM). For volume higher than 12,000 Liters (for e.g. How rates higher than 12,000 liters/minute) Gravimetric Calibration Campaign time will be varied according to the set flow ** Volumetric Method: Measuring Capacity By using One Diverter System & 2 Nos. of Large Volumetric Tanks (2000 - 3000L) (Cascaded Double Decker). Once Maximum Level (5000 L) reaches in Tank 1, the PROXIMITY SWITCH...
Open the catalog to page 18
FLUID FLOW CALIBRATION LABORATORY Nagman's Centre for Calibration is the first Calibration Laboratory in India to be Accredited as per ISO/IEC 17025:2005 being managed by dedicated, highly qualified, trained & Competent Experts in the field of Calibration to take care of all types of Customer's specific requirements & provide solution. Centre for Calibration is a unit of Nagman Instruments & Electronics Private Ltd., Chennai. This Calibration Lab is Accredited by NABL India to provide Calibration Services as per ISO/IEC 17025:2005 Standards. The Team consists of Qualified & NABL Empaneled...
Open the catalog to page 19
DOMESTIC GAS METER CALIBRATION SYSTEM BELL PROVER METHOD GASCAL SERIES Calibration method for any particular flow meter is governed by the meter type, the ranges of flow and flow conditions, pressure, temperature and the accuracy of calibration required. In general all the methods have analogies with the liquid methods. The main difference between the calibration of a gas flow meter and a liquid device is the compressibility of the fluid. When calibrating a gas flow meter the temperature, pressure and hence volume of gas measured by the standard will be different from that at the device...
Open the catalog to page 20
GASCAL SYSTEM BELL PROVER
Open the catalog to page 21
DOMESTIC GAS METER CALIBRATION SYSTEM BELL PROVER METHOD The 'Calibration Standard' of the Test system is "Bell Prover", which is considered a Primary (Calibration) Standard to Test & Calibrate Domestic Gas Meters. The device is ideal for OEMs, Calibration Laboratories & Calibration Service Providers. The Test System with Bell Prover of Capacity (100L) will effectively cover Vey Low (Q min - 0.016 mVhr.) to Maximum (Q max - 4 mVhr.) Flow Rates. Accuracy: 0.5% F.S. It can test Q-max, 0.2Q-max, and Q- min separately as per different gas meters. Bell Prover has built-in Pump to deliver the Air...
Open the catalog to page 22
DOMESTIC GAS METER CALIBRATION SYSTEM BELL PROVER METHOD The 'Calibration Standard' of the Test system is "Bell Prover", which is considered a Primary (Calibration) Standard to Test & Calibrate Domestic Gas Meters. The device is ideal for OEMs, Calibration Laboratories & Calibration Service Providers. The Test System with Bell Prover of Capacity (200L) will effectively cover Vey Low (Q min - 0.016 m7hr.) to Maximum (Q max - 4 mVhr.) Flow Rates. Accuracy: 0.5% F.S. It can test Q-max, 0.2Q-max, and Q- min separately as per different gas meters. Bell Prover has built-in Pump to deliver the Air...
Open the catalog to page 23All Nagman Instruments & Electronics (P) Ltd. catalogs and technical brochures
-
Product Catalog Hand Book
48 Pages
-
MTC 650
2 Pages
-
ETC 600/ETC 600-2
1 Pages
-
MTC 1200
2 Pages
-
Centre for Calibration
4 Pages
-
Level Transmitters
4 Pages
-
Level Calibration System
1 Pages
-
Tri-Phase Metering Systems
4 Pages
-
Flow Meters
8 Pages
-
Foreign Principal Products
8 Pages
-
Test Bench
24 Pages
-
Product Flier
4 Pages
-
Product Catalog Hand Book
48 Pages
-
GCL & GCH Series
2 Pages
-
HHP Series
2 Pages
-
PHP2 Series
2 Pages
-
Model BBS-VH
2 Pages
-
Model BBSD
2 Pages
-
BBSL, BBSM & BBSH
2 Pages
-
Model 1500HN
2 Pages
-
Model 1200HN
2 Pages
-
Model MTC650
2 Pages
-
Model MP650
2 Pages
-
Model 650H
2 Pages
-
Model 350H
2 Pages
-
Model MP40R
2 Pages