Programmable timer TP10V36A1 TYPE These timers control the opening and closing of feeding electromagnet. They have two operation ways: 1) Cyclical: Two possibilities at scheduled time, ON-OFF and OFF-ON. 2) Simple: Two possibilities at scheduled time, ON and OFF. Standard voltage: from 7 to 36VDC Maximum intensity: 1A Adjustable time: from 1 sec until 99h59min59sec Work temperature range: -10ºC to 50ºC Protection rate IP: IP65 mounted on base of connector DIN43650A General dimensions First two figures (beginning by the left) represent the hours, next two figures are the minutes and the last two are the seconds. MODE: Menu setting key. . Press this key during the operation, stops the work. .Press this key during stopping for selection mode. .After time setting press it to confirm NAFSA S.L. Model: TP10V36A1 Voltage: DC7-36V Switch: 1A ADD: increases the time DEC: decrease the time RESET: Key for reset and test. If it is pressed when stopping: Reset and stars to work. If it is pressed when working: tests if it works properly. IND: light on indicate ON and light off indicates OFF. TIMER SETTING: 1- Feed at standard voltage. 2 - Press MODE: the display shows (00.00.00), it's setted on stop mode. 3 - Press MODE: display screen shows (CLOSE) 4-Press MODE: set the closing time using ADD and DEC buttons. 5 - Press MODE: display screen shows (OPEN) 6 - Press MODE: set the openning time using ADD and DEC. 7 - Press MODE: We begin setting working mode. Using ADD and DEC buttons we can use four working modes: ON (the electromagnet is under voltage during OPEN time, and then it is disconnected until reset); OFF (the electromagnet is not under voltage during CLOSE time and then it is connected until reset); ON-OFF (the electromagnet works in a ON-OFF cycle until reset); OFF-ON (the electromagnet works in a OFFON cycle until reset). Once setted the working mode it must we confirmed by pussing MODE. RESET: Press RESET or stop power voltage supply. Voltage feeding face: 7 to 36VDC (it does not require polarization). WARNING: Do not connect the electromagnet to these terminals NAFSA, se reserva toda posibilidad de modificación Terminal 1 Connector base Terminal 2 Voltage exit face to the electromagnet. It is possible to be mounted in combination with electrical economizer EEC40-24-50 (See document A.1) Ordering code:

Open the catalog to page 1

All NAFSA catalogs and technical brochures

  1. CU20CP25-E

    1 Pages

  2. CU20CP100-E

    1 Pages

  3. CU20CPB

    1 Pages

  4. CU20CP25-2L

    1 Pages

  5. CU20CP100-2L

    1 Pages

  6. CP38

    1 Pages

  7. C30-M5-NC2

    1 Pages

  8. ERM300-35

    1 Pages

  9. VM135E

    1 Pages