Flow Switch™ (Model FS4)
2Pages

{{requestButtons}}

Catalog excerpts

Flow Switch™ (Model FS4) - 1

FLOW SWITCH - Model FS4 Compatible with the CTCII and In-Line Monitor/controllers WHITE (2) 22 AWG LEAD WIRES 18" (457) LONG Service: Compatible liquids Wetted Materials: Housing and Shuttle: Noryl GFN3 (Polyphenylene Ether and Polystyrene) Spring: 316 Stainless Steel Retaining Clip: pH 15-7 MO Stainless Steel Magnet: Ceramic 1 Temperature Limits: 0 - 194°F/-21 - 90°C Pressure Limit: 100 psig/6,90 bar @ 70°F/21°C, 50 psig/3,45 bar @ 194°F/90°C Switch Type: SPST normally open hermetically sealed reed switch Electrical Rating: 1.5A @ 24 VDC resistive, 0.001A @ 200 VDC resistive, 0.5A @ 125 VAC Accuracy: ±20% Electrical Connections: 22 AWG, 18 in./460 mm long Process Connection: 3/4˝ FNPT Mounting Orientation: Switch can be installed in any position but the actuation flow rates are based on vertical up flow pipe runs and are nominal values. Set Point: 1.0 GPM activation on increasing flow Weight: 4.2 oz./0,119 kg Deadband: 20% maximum 1. CAUTION: Mechanical shock or vibration can cause permanent damage to the reed switch. Take care to avoid dropping the unit on hard surfaces or impacting the switch assembly. Note: Standard units are designed with springs for positive return of the shuttle at no-flow condition. This allows the Flow Switch to be mounted in any orientation, but actuation set points vary from stated values. 2. Liquid media containing particulate and/or debris should be filtered to ensure proper operation of the FS4 Flow Switch. 3. Apply Teflon® thread tape or sealant to the 3/4” MNPT pipe threads and install the switch into the piping system. Thread the Flow Switch onto the male pipe thread until hand-tight. Tighten pipe one additional turn. If improper seal results, continue turning pipe into Flow Switch in 1/4-turn increments. Do Not Exceed 1 Additional Turn. 4. Connect wiring in accordance with local electrical codes. 5. Inductive, capacitive, and lamp loads can all create conditions harmful to the reed switch. A) Inductive loads can be caused by electromagnetic relays, electromagnetic solenoids, and electromagnetic counters, all with inductive components as the circuit load. Continued Teflon® is a registered trademark of E.I. du Pont de Nemours and Company. Noryl® is a registered trademark General Electric Company. Water Quality Instrumentation Accuracy • Reliability

Open the catalog to page 1
Flow Switch™ (Model FS4) - 2

Capacitive loads can be caused by capacitors connected in series with or parallel to the reed switch. In a closed circuit the cable length (150 ft./45 meters or more) to the switch can introduce a capacitance. C) Lamp loads can be caused by switching lamp filaments, which have low cold resistance. In addition to these causes, exceeding any of the maximum electrical ratings can lead to premature or immediate failure. This includes inrush and surge currents greater than the maximum switching current. Use caution when evaluating system loads and current. 2450 Impala Drive Carlsbad, CA...

Open the catalog to page 2

All Myron L Company catalogs and technical brochures

  1. POOLPRO™

    4 Pages

  2. RO METERS™

    2 Pages

  3. POOLMETER™

    2 Pages

  4. LITHO-KIT™

    2 Pages

  5. CTCII™

    2 Pages

  6. TECHPRO

    2 Pages

  7. PoolMeter

    2 Pages

  8. POOLPRO

    4 Pages

  9. AGRI-METERS

    2 Pages

  10. AG-STIK

    2 Pages

  11. aquaswitch

    2 Pages