Product catalog summary
Overview: The document provides detailed information about Myron L Dialysate Meters, which are instruments used for testing dialysate solutions in medical settings. These meters are known for their accuracy, reliability, and simplicity, and have been trusted by hemodialysis professionals for over 35 years.
Features:
  • Fast and accurate testing of dialysate solutions.
  • Models available for both acetate and bicarbonate solutions.
  • Durable polyethylene cell cup resistant to chips and cracks.
  • Rugged and simple design with automatic temperature compensation.
Models:
  • Model D-1: Features an expanded scale of 11-15 millimhos, suitable for testing final dialysate. It includes an adjustable green color band for visual confirmation of safe dialysate concentration.
  • Model D-2: Offers dual scales for testing both acetate and bicarbonate dialysate, with ranges of 0-10 and 0-20 millimhos.
Specifications:
  • Accuracy: ±2% of full scale, ±1% at calibration point.
  • Repeatability: ±1%.
  • Automatic temperature compensation to 25°C/77°F for samples between 10-71°C/50-160°F.
  • Powered by two 9-volt batteries, lasting approximately 1 year or 2,000 tests.
  • Dimensions: 3.4 W x 4.5 D x 4.0 H inches (86 x 114 x 102 mm).
  • Weight: 1 lb (450 grams).
Accessories:
  • Standard Solutions for recalibration to ensure accuracy.
  • Porta-Pak Carry Case for protection during transport.
Warranty: The meters come with a two-year limited warranty covering materials and workmanship, with conditions for repair or replacement.
Additional Information: The document emphasizes the importance of automatic temperature compensation for accurate readings and provides contact information for further inquiries.
See more

Catalog excerpts

Dialysate Meters™ Single & Dual Range-1

DIALYSATE METERS™ Single and Dual Range Meters Reliable Conductivity Instruments for Testing Dialysate Solutions in the Hospital, Clinic, or Home FEATURES • Fast and accurate dialysate tests • Models for both acetate and bicarbonate solutions • Chip and crack resistant polyethylene cell cup • Rugged design • Simple to use • Automatic temperature compensation Calibration Solution The choice of hemodialysis professionals for over 35 years, these compact instruments have been designed specifically to test dialysate solutions. By measuring electrical conductivity, they will quickly determine if dialysate concentrations are correct. To use these hand-held instruments, the operator simply fills the cell cup with dialysate solution and pushes a button. The needle indicates the total concentrations of salts in the solution. Model D-1 has an expanded scale of 11-15 millimhos and is useful for testing final dialysate. A unique feature of this model is the adjustable green color band above the dial. This provides an immediate visual confirmation of whether or not the dialysate concentration is within the patient’s “safe zone”. Model D-2 features dual scales on the dial and can test both acetate and bicarbonate dialysate. Both instruments have built-in cell cups and are completely selfcontained. They are powered by 9-volt batteries which last for at least 2,000 tests. A glow light serves as a battery reserve indicator. Thousands of Myron L Dialysate Meters are still in daily use around the world after years of reliable service. For more information, please visit our website at: www.myronl.com FDA Establishment Registration #2020976 Water Quality Instrumentation Accuracy • Relia

 Open the catalog to page 1
Dialysate Meters™ Single & Dual Range-2

AUTOMATIC TEMPERATURE COMPENSATION: WHY IT’S IMPORTANT The graph at the right illustrates conductivity readings of a 14.0 millimhos dialysate sample tested with a nontemperature compensated conductivity meter. The same sample APPEARS to have a higher level of dialysate concentration when heated (and lower concentration when chilled). Actually, only conductivity readings change with temperature. Dialysate concentration does not change. Some instruments ignore the importance of temperature. Others require a separate thermometer for testing sample temperature then manual adjustment of the meter....

 Open the catalog to page 2

All Myron L Company catalogs and technical brochures