1. Catalogs
  2. Myron L Company
  3. CONDUCTIVITY SENSORS: CS951 & CS951LS

CONDUCTIVITY SENSORS: CS951 & CS951LS
1 /2Pages

CONDUCTIVITY SENSORS: CS951 & CS951LS

CONDUCTIVITY SENSORS: CS951 & CS951LS
1 /2Pages

Catalog excerpts

CONDUCTIVITY SENSORS: CS951 & CS951LS-1

CONDUCTIVITY SENSORS: CS951 & CS951LSConductivity Sensors for 900 Series Multi-Parameter Monitor / Controllers • Measurement range from 0 to 20,000 pS. • Can be installed in-line, in a tank or as a submersion sensor1. • Dual O-ring seals for long term, in stream reliability. • Customized cell constant is verified on each sensor for best accuracy. BENEFITS • Low Cost / High Performance. • Temperature and Chemically Resistant Construction. • Cable Lengths Up to 100ft Available. • Built in Temperature Sensor Measures Solution Temperature Directly. DESCRIPTION The Myron L® Company CS951 and CS951LS Conductivity sensors are designed to operate in demanding environments. They are an excellent sensor for a wide variety of water quality applications. Process connections are made via a 3/4” NPT fitting. This fitting may be installed into a line or tank, or may be reversed so that the sensor can be inserted into a standpipe for use in submersion applications1. The standard versions have a 316 stainless steel body and fittings made from temperature resistant and chemically non-reactive polypropylene. Optional fittings of stainless steel or PVDF (polyvinylidene difluoride) are available for even better chemical and temperature resistance. All CS951 and CS951LS sensors are completely encapsulated and feature a dual O-ring seal design that ensures long life under demanding conditions. The outer O-ring bears the brunt of environmental attacks allowing the inner O-ring to maintain a reliable seal. The built-in PT1000 RTD makes accurate and quick temperature measurements for superior temperature compensation2. Standard cable length is 10ft. (3.05m) terminated with 5, tinned leads (4 signal; 1 shield; separate 5-pin terminal block included). They are also available with optional 25ft (7.6m) or 100ft (30.48m) cables. For more information please visit our website at www.myronl.com 1 Sensor back seal at cable exit is not water tight. ALWAYS mount the sensor in a standpipe for submersion applications. andassembledintheusa 2 Temperature compensation can be deactivated to meet USP (United States Pharmacopoeia) requirements. MYRON L®| COMPANY J Water Quality Instrumentation Accuracy • Reliability • Simplicity

 Open the catalog to page 1
CONDUCTIVITY SENSORS: CS951 & CS951LS-2

Measurement Range: 1 Actual Cell Constant for each sensor is verified and recorded on the P/N label attached to the sensor cable. LIMITED WARRANTY Custom and OEM models available. All Myron L® Company Conductivity Sensors have a Two (2) Year Limited Warranty. If sensor fails to function normally, return the unit to the factory prepaid. If, in the opinion of the factory, failure was due to materials or workmanship, repair or replacement will be made without charge. A reasonable service charge will be made for diagnosis or repairs due to normal wear, abuse or tampering. Warranty is limited to the...

 Open the catalog to page 2

All Myron L Company catalogs and technical brochures

  1. POOLPRO™

    4  Pages

  2. POOLMETER™

    2  Pages

  3. RO METERS™

    2  Pages

  4. AGRI-METERS

    2  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.