video corpo

Water Cooled Reactors

Water Cooled Reactors

Water Cooled Reactors

Product catalog summary
General Information
Water cooled reactors are designed for continuous duty at nominal current with a design lifetime of 20 years. They feature a 3-phase inductor electrical connection and an open frame design with IP 00 protection class. The cooling type is liquid-based.
Mechanical Specifications
The maximum dimensions are 1000 x 1000 x 1000 mm, and the weight is less than 1000 kg. The reactors comply with vibration standards EN50178 and EN60068-2-6, and impact standards EN50178 and EN60068-2-27.
Connections
Electrical connections are made using copper/aluminium busbars, with a protective earth connector ranging from M8 to M12. Liquid cooling connections are specified by the customer, and temperature sensors are connected via a terminal block.
Electrical Specifications
The nominal voltage between phases is up to 1500 Vac, with a nominal current of up to 3000A. The continuous thermal current is 3000A, and the fundamental frequency is typically 50-60 Hz. The du/dt voltage is a maximum of 3000V/us. Inverter switching frequency ranges from 1.5-4.0 kHz with laminated steel and 5-10 kHz with amorphous steel. The isolation test voltage is 2500 Vac for 60 seconds, and insulation resistance is greater than 2 MΩ. The temperature class of the insulation is Class H (180 °C), and the electrical insulation system is UL recognized.
Liquid Cooling System
The cooling liquid is an ethylene glycol/water mixture, with a recommended ratio of 30/70%. The temperature range for the cooling liquid is -40 to +55 °C, with a nominal temperature of +50 °C. The maximum temperature of the cooling liquid (out) is +90 °C. The nominal liquid flow is a maximum of 10 dm3/min, with a maximum required flow of 15 dm3/min. The system is designed to dissipate a minimum of 70% heat to the liquid at 40 °C ambient temperature.
Ambient Operating Conditions
The ambient temperature range for operation is 5 to +65 °C, and for storage, it is -40 to +80 °C. Air humidity during operation is 5 to 96%, and in storage, it is 5 to 99%. The ambient air pressure ranges from 930 to 1065 mbar, and the maximum height from sea level is 1500 m. Maximum heat dissipation to air is 30% at 40 °C ambient temperature.
See more

Catalog excerpts

Water Cooled Reactors-1

TRAFOX FILTERS WATER COOLED REACTORS UP TO 3000A Water cooled reactors 1400A - 90µH General information Electrical connection: Protection class: Type of cooling: Running period: Design lifetime: 3 -phase inductor Open frame design IP 00 Liquid Continuous duty at nominal current 20 years Mechanical specification Maximum size (LxWxH): 1000 x 1000 x 1000 mm Maximum weight: < 1000 kg Vibration: EN50178, EN60068-2-6 Impacts: EN50178, EN60068-2-27 Connections Electrical connection: Copper/ aluminium busbars Protective earth connector: M8-M12 connector Liquid cold (in): Acc. to customer specification Liquid cold (out): Acc. to customer specification Temperature sensor: Terminal block Schematic diagram

 Open the catalog to page 1
Water Cooled Reactors-2

TRAFOX FILTER Water cooled reactors Temperature sensors ELECTRICAL SPECIFICATIONS Nominal voltage between phases Nominal current Continuous thermal current Peak value of current Fundamental frequency Du/dt voltage Inverter switching frequency 2- wired Pt-100 sensors at the hot spot of each winding Current ripple at switching frequency Propo Isolation test voltage Uisol Insulation resistance Rins Nominal phase inductance at peak current Lnom Maximum inductance difference between phases < 10% Saturation current Isat Saturation inductance Lsat Leakage capacitance between terminals of one phase Cleak...

 Open the catalog to page 2
Water Cooled Reactors-3

TRAFOX FILTERS Water cooled reactors LIQUID COOLING SYSTEM Cooling liquid Temperature of the cooling liquid (in) Nominal temperature of the cooling liquid (in) Maximum temperature of the cooling liquid (out) Nominal liquid flow Maximum required liquid flow Minimum heat dissipation to liquid Maximum pressure drop Maximum operating pressure Testing pressure Selection of materials in direct contact with liquid Ethylene glycol / water mixture 0/100…40/60%. 30/70% recommended Inhibitor enriched coolants for corrosion preventation. Range -40…+55 °C +50 °C +90 °C maximum 10 dm3/min maximum 15 dm3/min...

 Open the catalog to page 3
Water Cooled Reactors-4

Also 1 phase customer specified models! Muuntosähkö Oy - Trafox FINLAND - ESTONIA - CHINA P.O. Box 10, FI-00621 Helsinki, tel. +358 207 933 700, fax. +358 207 933 746, www.trafox.fi, [email protected]

 Open the catalog to page 4
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.