Catalog excerpts
transformer series Control transformers
Open the catalog to page 1TRAFOX TRANSFORMERS LH-series 1- PHASE LOW VOLTAGE ISOLATION TRANSFORMERS, IP2X PROTECTED: The transformers are designed to have multiple functions and technical properties. This series of transformers fulfills the most common standards, including the naval requirements. The properties are meant to satisfy even the most demanding requirements. When designing this series of transformers, we have taken into account the need to reduce direct power losses, the indirect losses in production, storage and logistics as well as environmental aspects. transformer series These transformers are...
Open the catalog to page 2ORDER CODE: LH40_24 MODEL: LH40-230-400/24 trafox transformers lh -series TECHNICAL DATA Primary winding Secondary winding Power Frequency Protection class Isolation voltage Insulation class Ambient temperature Standard Mounting MEASUREMENTS POWER 40VA Order code ORDER CODE: LH40_230 MODEL: LH40-230-400/230 TECHNICAL DATA Primary winding Secondary winding Power Frequency Protection class Isolation voltage Insulation class Ambient temperature Standard Mounting 230/400V ±5% 230V AC 40VA 50/60Hz IP2X 4kV AC T60/B -20...+60°C EN61558-2-4, CE Screw or DIN rail mounting Order code
Open the catalog to page 3ORDER CODE: LH63_24 MODEL: LH63-230-400/24 TECHNICAL DATA Primary winding Secondary winding Power Frequency Protection class Isolation voltage Insulation class Ambient temperature Standard Mounting MEASUREMENTS 230/400V ±5% 24V AC 63VA 50/60Hz IP2X 4kV AC T60/B -20...+60°C EN61558-2-6, CE Screw or DIN rail mounting Order code ORDER CODE: LH63_230 MODEL: LH63-230-400/230 TECHNICAL DATA Primary winding Secondary winding Power Frequency Protection class Isolation voltage Insulation class Ambient temperature Standard Mounting 230/400V ±5% 230V AC 63VA 50/60Hz IP2X 4kV...
Open the catalog to page 4ORDER CODE: LH100_24 MODEL: LH100-230-400/24 trafox transformers lh -series TECHNICAL DATA Primary winding Secondary winding Power Frequency Protection class Isolation voltage Insulation class Ambient temperature Standard Mounting 230/400V ±5% 24V AC 100VA 50/60Hz IP2X 4kV AC T60/B -20...+60°C EN61558-2-6, CE Screw or DIN rail mounting POWER 100VA Order code ORDER CODE: LH100_230 MODEL: LH100-230-400/230 TECHNICAL DATA Primary winding Secondary winding Power Frequency Protection class Isolation voltage Insulation class Ambient temperature Standard Mounting 230/400V ±5% 230V...
Open the catalog to page 5ORDER CODE: LH160_24 MODEL: LH160-230-400/24 POWER 160VA TECHNICAL DATA Primary winding Secondary winding Power Frequency Protection class Isolation voltage Insulation class Ambient temperature Standard Mounting TECHNICAL DATA 230/400V ±5% 24V AC 160VA 50/60Hz IP2X 4kV AC T60/B -20...+60°C EN61558-2-6, CE Screw or DIN rail mounting Order code ORDER CODE: LH160_230 MODEL: LH160-230-400/230 Primary winding Secondary winding Power Frequency Protection class Isolation voltage Insulation class Ambient temperature Standard Mounting 230/400V ±5% 230V AC 160VA 50/60Hz IP2X 4kV...
Open the catalog to page 6ORDER CODE: LH250_24 MODEL: LH250-230-400/24 trafox transformers lh -series TECHNICAL DATA Primary winding Secondary winding Power Frequency Protection class Isolation voltage Insulation class Ambient temperature Standard Mounting 230/400V ±5% 24V AC 250VA 50/60Hz IP2X 4kV AC T60/B -20...+60°C EN61558-2-6, CE Screw or DIN rail mounting POWER 250VA Order code ORDER CODE: LH250_230 MODEL: LH250-230-400/230 TECHNICAL DATA Primary winding Secondary winding Power Frequency Protection class Isolation voltage Insulation class Ambient temperature Standard Mounting 230/400V ±5% 230V...
Open the catalog to page 7ORDER CODE: LH500_24 MODEL: LH500-230-400/24 POWER 500VA TECHNICAL DATA Primary winding Secondary winding Power Frequency Protection class Isolation voltage Insulation class Ambient temperature Standard Installation Order code ORDER CODE: LH500_230 MODEL: LH500-230-400/230 TECHNICAL DATA Primary winding Secondary winding Power Frequency Protection class Isolation voltage Insulation class Ambient temperature Standard Installation Order code
Open the catalog to page 8ORDER CODE: LH1000_24 MODEL: LH1000-230-400/24 TRAFOX TRANSFORMERS LH -SERIES TECHNICAL DATA Order code Primary winding Secondary winding Power Frequency Protection class Isolation voltage Insulation class Ambient temperature Standard Installation ORDER CODE: LH1000_230 MODEL: LH1000-230-400/230 TECHNICAL DATA Primary winding Secondary winding Power Frequency Protection class Isolation voltage Insulation class Ambient temperature Standard Installation Order code
Open the catalog to page 9ORDER CODE: LH1500_24 MODEL: LH1500-230-400/24 POWER 1500VA TECHNICAL DATA Primary winding Secondary winding Power Frequency Protection class Isolation voltage Insulation class Ambient temperature Standard Installation Order code ORDER CODE: LH1500_230 MODEL: LH1500-230-400/230 TECHNICAL DATA Primary winding Secondary winding Power Frequency Protection class Isolation voltage Insulation class Ambient temperature Standard Installation Order code
Open the catalog to page 10ORDER CODE: XHP2000_24 MODEL: XHP2000-230-400/24 trafox transformers lh -series TECHNICAL DATA Primary winding Secondary winding Power Frequency Protection class Isolation voltage Insulation class Ambient temperature Standard Installation Order code ORDER CODE: XHP2000_230 MODEL: XHP2000-230-400/230 TECHNICAL DATA Primary winding Secondary winding Power Frequency Protection class Isolation voltage Insulation class Ambient temperature Standard Installation Order code
Open the catalog to page 11trafox transformers lh -series ORDER CODE: XHP3000_24 MODEL: XHP3000-230-400/24 TECHNICAL DATA Primary winding Secondary winding Power Frequency Protection class Isolation voltage Insulation class Ambient temperature Standard Installation Order code ORDER CODE: XHP3000_230 MODEL: XHP3000-230-400/230 TECHNICAL DATA Primary winding Secondary winding Power Frequency Protection class Isolation voltage Insulation class Ambient temperature Standard Installation Order code
Open the catalog to page 12ORDER CODE: XHP4000_24 MODEL: XHP4000-230-400/24 trafox transformers lh -series TECHNICAL DATA Primary winding Secondary winding Power Frequency Protection class Isolation voltage Insulation class Ambient temperature Standard Installation Order code ORDER CODE: XHP4000_230 MODEL: XHP4000-230-400/230 TECHNICAL DATA Primary winding Secondary winding Power Frequency Protection class Isolation voltage Insulation class Ambient temperature Standard Installation Order code
Open the catalog to page 13All Muuntosähkö Oy - Trafox catalogs and technical brochures
-
Medical Transformers
4 Pages
-
DU/dt filters
4 Pages
-
Sine filters
2 Pages
-
LH series Control transformers
16 Pages
-
Sine Filters 460-1460A
2 Pages
-
LC Control Transformers
2 Pages
-
Water Cooled Reactors
4 Pages
-
Power Transformers Eco
2 Pages
-
Power Transformers brochure
2 Pages