MICO-Family
12Pages

{{requestButtons}}

Catalog excerpts

MICO-Family - 1

mico Solutions for Intelligent Power Distribution ÔÔ Monitor ÔÔ Detect ÔÔ Switch Off

Open the catalog to page 1
MICO-Family - 2

02 | 03 vital to your system Thousands of satisfied customers Murrelektronik offers you... ontrol cabinet construction C Transformers Machine tools Switch mode power supplies Packaging industry I ntelligent power distribution Logistics uffer module B Process automation edundancy modules R Food&Beverage

Open the catalog to page 2
MICO-Family - 3

| SOLUTIONS FOR INTELLIGENT POWER DISTRIBUTION Complex power supply systems with many components require reliable load protection. Switch mode power supplies are the core of these systems since they electronically monitor output voltage and output current. If there is a short circuit or an overload, protective devices downstream (for example circuit breakers) react slower than the power supply and do not ensure selectivity. This can cause critical situations like voltage drops or even cable fires. Our compact MICO modules help eliminate these problems: MICO is an essential component for...

Open the catalog to page 3
MICO-Family - 4

04 | 05 | MICO – Solutions for intelligent power distribution CASCADING START MICO eliminates start-up peaks with a time-delayed (cascading) start of individual current paths. Advantage: Now you can use power supplies with lower output current. I nom (A ) competitor MICO 100 % 70 % channel 1 channel 2 channel 3 channel 4 Target-oriented protection is a big challenge for modern power supply systems. MICO is an intelligent power distribution system that meets this challenge! Errors are found quickly while availability remains high. MICO Monitors Currents: You can select a maximum, individual...

Open the catalog to page 4
MICO-Family - 5

stay connected EXAMPLE FOR A 6 A CIRCUIT BREAKER IN A 24 V DC SYSTEM Installation wire * Circuit breaker Specific resistance of copper (p) Wire resistance: Distributor cable resistance: Sensor cable resistance: Distributor cable Inner resistance of circuit breaker and connection terminals Sensor cable Total loop resistance Calculation of maximum possible current flow 1= — (limited by loop resistance) Required tripping current of the 6 A circuit breaker Type C Tripping current Max. current flow | THE PERFECT MICO FOR ANY APPLICATION For more information see our online shop

Open the catalog to page 5
MICO-Family - 6

06 | 07 | MICO+ – appealing features and even more options Mico saves energy: When loads are switched on, they need energy. Often current is already flowing, even though no productive activity is carried out. For example during pause times: Energy is consumed as stand-by power, pumps are running, displays lighten, loads are heating ... With MICO+ you can switch off all 4 output channels from a control input during idle times. This way, only those loads that actually require energy are supplied. This saves energy, results in fewer losses, increases lifetime and productivity. If the part of...

Open the catalog to page 6
MICO-Family - 7

YOUR BENEFITS 90 % warning notice – now available as digital signal: MICO's visual 90 % warning notice is a perfect tool for setting up machines and systems. If channels are near the limit, the LED starts blinking. Often the total current needed increases during operation. This happens for example, because valves and motors wear out. Therefore, the MICO+ 90 % warning notice is additionally available as signal. The signal is transferred to the control, the control sets off the alarm – and counter-measures can be immediately taken. ave energy during idle times S eact early to creeping...

Open the catalog to page 7
MICO-Family - 8

08 | 09 | MICO CLASSIC – Top Class Power Distribution Allows remote start with 24 V DC signal anually switch on each channel for start-up and shut-down M LED status indication for each channel Proven bridge concept connects several MICOs Minimum output resistance, almost no power loss ptimum labeling options, for device location and channels O Maintenance-free with spring clamp terminals Adjustable current range for each channel erfect shut-down function: as late as possible, as early as P necessary Visual warning notice when 90 % of the load current set is reached Less is more...

Open the catalog to page 8
MICO-Family - 9

| MICO CLASSIC 4.4.10 Actuator Sensor – FOR ANY APPLICATION MICO CLASSIC 4.4.10 Actuator-Sensor features two channels to protect sensors (current range 1 to 4 A) and two channels to protect actuators (4 to 10 A). It covers the complete current range from 1 - 10 A in one compact device! PERFECT FIT MICO CLASSIC is available in a two channel and four channel version: The modules can be installed in any combination to ensure a cost-effective and spacesaving system design. They are linked with a bridge set. This minimizes wiring efforts. 1…10 A channels, width 36 mm 2 channels, width 70 mm 4...

Open the catalog to page 9
MICO-Family - 10

10 | 11 | MICO BASIC – INTELLIGENT SWITCH OFF As early as necessary, as late as possible – MICO BASIC features intelligent switch off characteristics! The modules are suitable for any application that requires protection of a great number of sensors and actuators with similar demands. The current ranges for the individual circuits are fixed. The compact modules secure either four or eight channels with 2, 4, or 6 A. LEDs show the operating conditions of the individual channels and, when blinking, indicate that a maximum load of 90 % is reached. If there is an overload or short circuit, MICO...

Open the catalog to page 10
MICO-Family - 11

| MICO FUSE – COST-EFFECTIVE MONITORING WITH GLAS TUBE FUSES Protecting sensors and actuators is very important. However, using individual safety terminals requires time-consuming efforts. Now MICO FUSE makes this protection more convenient! The compact module features eight sockets for glass tube fuses that can be accessed from the front. It protects eight channels. MICO FUSE 24 LED has additional LEDs that indicate the operating condition of each channel in red and green. A group alarm contact sends the current status to the control. Sockets for 8 – accessible from the front glass tube...

Open the catalog to page 11
MICO-Family - 12

MICO – Solutions for Intelligent Power Distribution|09_12 EN|Art. No. 9843022 The information in this brochure has been compiled with the utmost care. Liability for the correctness, completeness and topicality of the information is restricted to gross negligence. ÔÔ www.murrelektronik.com

Open the catalog to page 12

All MURRELEKTRONIK catalogs and technical brochures

  1. F&B PRO

    2 Pages

  2. GENERAL CATALOG

    789 Pages

  3. ECO-RAIL-2

    2 Pages

  4. Cordsets

    4 Pages

  5. MASI20

    2 Pages

  6. Mico Pro®

    3 Pages

  7. Exact12 ATEX

    1 Pages

  8. Emparro67

    2 Pages

  9. Emparro MEF

    2 Pages

  10. Emparro Cap

    2 Pages

  11. Emparro

    2 Pages

  12. Demagnetizer

    2 Pages

  13. Cube20S

    2 Pages

  14. Cube

    8 Pages

  15. Comlight57

    2 Pages

  16. Brandlabel

    6 Pages

  17. Insights

    32 Pages

  18. Impact20

    2 Pages

  19. MIRO BT

    6 Pages

  20. Insight

    32 Pages

  21. AS Interface

    24 Pages

  22. Transformers

    12 Pages