True-RMS-AC Ammeters with Built-in CT FEATURES  Built-in CTs provide true-rms values of complex waveforms  Perfect for measuring AC current in IT applications  ranges measure: 0-0.2A, 0-2A, 0-20A, 0-30A Five and 0-50A  models features a split-core CT for easy installation 50A  Self-powered from 85-140Vac or 170-264Vac  Large, easy-to-read, red LED display with 0.37" digits  Reliable single-board construction  Digital replacement for analog meters  Approvals to UL/cUL/IEC/61010-1 Murata Power Solutions’ new ACA-20RM Series are the world’s first digital ac-ammeters to incorporate a built-in current transformer (CT) to directly measure the true-rms value of complex, non-sinusoidal ac currents from 2 to 50A – no bulky and expensive 5A “donut” CTs are required! Operation and setup is straightforward: simply pass the load-carrying wire through the on-board CT, apply power, and the ammeter is fully operational. Five input ranges measure 0-0.2 amps (0.1mA resolution), 0-2 amps (0.001A resolution), 0-20 amps (0.01A resolution), 0-30 amps (0.1A resolution) or 0-50 amps (0.1A resolution). The 50A model features an oversized split-core current transformer that easily accommodates wires sizes up to 4 AWG (21.2mm2). Two power supply options are available: 85-140V (47-63Hz), and 170-264V (47-63Hz). All models are totally self-contained; no external components are required. Power consumption from a nominal 120V or 220V ac supply is less than 50mA. And, precision autozeroing circuitry, super-stable components, and an rms-to-dc converter circuit combine to achieve excellent performance when measuring the complex, non-sinusoidal, ac currents found in today’s computer/telecom equipment. ACA-20RM Series ammeters feature full-size, 0.37" (9.4mm) high, 3½ digit, bright red LED-displays and a built-in bezel/filter assembly that features metal fasteners. They are panel-cutout compatible with MPS’s DMS-20 Series of ac voltage and frequency monitors, making ACA-20RM ammeters perfect replacements for older, less reliable, analog panel meters in today’s sophisticated IT instrumentation. RMS-to-DC CONVERTER BUILT-IN CURRENT TRANSFORMER POWER CONVERTER For full details go to www.murata-ps.com/rohs MEASURED AC LOAD CURRENT

 Open the catalog to page 1
ACA-20RM-1-AC3-RL-C-2

Mu rata Power Solutions ACA-20RM SeriesTrue-RMS-AC Ammeters with Built-in CT Input Range: Performance/Functional Specifications Typical at Ta = +25°C, unless otherwise noted. © Specified full-scale currents are those passing through the ammeter's built-in current transformer's primary load-circuit. See Notes 2 and 3 below for additional model-specific information. © The overcurrent rating of 1.5 x the rated full-scale current is a continuous rating and applies to the current passing through the built in current transformer only, it does not apply to any external circuit-wiring or external loads....

 Open the catalog to page 2
ACA-20RM-1-AC3-RL-C-3

ACA-20RM Series True-RMS-AC Ammeters with Built-in CT The calibration potentiometer has approximately ¾ of a turn of rotation; do not force its adjustment screw past the end stops. Contact MPS if additional information is required regarding calibration, setup, or any other technical issue pertaining to ACA-20RM ac ammeters. 3. Wire Gauges and Fusing: Wires specified in the Functional Specifications section must be used for making connections to ACA-20RM series ammeters. All power-supply and load wiring must be rated for the supply voltages and currents they will conduct and must comply with any...

 Open the catalog to page 3
ACA-20RM-1-AC3-RL-C-4

ACA-20RM Series True-RMS-AC Ammeters with Built-in CT PANEL INSTALLATIONS All connections to ACA-20RM Series ammeters must be made after the ammeter is securely attached to its panel and with all associated load and supply voltages de-energized (off). However, using extreme caution and observing all safety measures applicable to the user’s installation, 50A split-core CT models can be connected to energized current-carrying load conductors, but connections to TB1 must always be made with the ammeter’s power source off. Using Figure 4 as a guide, carefully insert the bezel/color filter assembly...

 Open the catalog to page 4
ACA-20RM-1-AC3-RL-C-5

ACA-20RM Series True-RMS-AC Ammeters with Built-in CT MECHANICAL SPECIFICATIONS Lead Length 2.0 (50.5) min. 0.35 (8.9) Diameter MECHANICAL DIMENSIONS: Inches (mm) TOLERANCES: 2 PL DEC ±0.02 (±0.51) 3 PL DEC ±0.010 (±0.254) 1. Description of safety marks: Caution, risk of electrical shock Caution, risk of danger Equipment is protected throughout by double or reinforced insulation 2. Cleaning Instructions: Gently clean with dry cloth only. 3. Caution: if the equipment is used in a manner not specified by Murata Power Solutions, the protection provided by the equipment may be impaired. Murata Power...

 Open the catalog to page 5

All Murata Power Solutions catalogs and technical brochures

  1. ACM3P Series

    6  Pages

  2. NXF1 Series

    9  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.