AIR DRIVEN LIQUID PUMPS
14Pages

{{requestButtons}}

Catalog excerpts

AIR DRIVEN LIQUID PUMPS - 1

Plant, components and devices for very high and high pressures (7000 bar and over) LIQUID PUMPS SERIES R AND R2

Open the catalog to page 1
AIR DRIVEN LIQUID PUMPS - 2

INTRODUCTION MCS® air-driven pumps operate on the simple but efficient principle of an automatic reciprocating differential area piston. A relatively large air-operated is connected to a smaller high-pressure piston to convert compressed air flow into fluid flow at high pressure. MCS® offers a complete range of single acting ratio pumps and double ratio pumps. The single acting pumps (R series) have one air piston and one high-pressure piston. The double ratio (R2 series) have two air piston and one high pressure piston. The diameter of the hydraulic piston varies and determines the ratio...

Open the catalog to page 2
AIR DRIVEN LIQUID PUMPS - 3

Check valve seats can be replaced within minutes. The check valves have soft seats, preventing capacity loss after a certain time of operating. Unlike other air driven pumps the air piston sealing and the pilot valve sealing of a MCS® airdriven pump is not an O-ring. It is provided with PTFE based slydrings (bearings) for excellent wear- and-slide qualities. The slydrings increase the service life of the sealing surface (air cylinder/air pilot valve) and the air piston sealing. Excellent control of flow and output pressure due to low frictional resistance of the air piston, even at low air...

Open the catalog to page 3
AIR DRIVEN LIQUID PUMPS - 4

As the frictional resistance of the MCS® air-driven piston is very low, only a small pressure drop or air drive pressure increase is required to restart the pump. The MCS® air-driven pumps can be mounted in any position. For maintenance reasons you are advised to mount pumps in vertical position, using the four thread holes in the air drive end caps or the mounting brackets. The pumps will deliver their rated capacity at 7 bar (101.5 psi) air drive pressure with the required air flow. The air supply line requires an air pressure regulator to control the output of the pump and a pneumatic...

Open the catalog to page 4
AIR DRIVEN LIQUID PUMPS - 5

NPT CONNECTION NPT threads must be sealed using a high quality PTFE tape and/or paste product. Refer to thread sealant manufacturer's instructions on how to apply thread sealant. - Sealing performance may vary based on many factors such as pressure, temperature, media, thread quality, thread material, proper thread engagement and proper use of thread sealant. - Customer should limit the number of times an NPT fitting is assembled and disassembled because thread deformation during assembly will result in deteriorating seal quality over time. When using only PTFE tape, consider using thread...

Open the catalog to page 5
AIR DRIVEN LIQUID PUMPS - 6

R SERIES LOW PRESSURE HIGH VOLUME PUMP Model R020 R040 All dimension are for reference only and are subject to change Technical Data Air drive pressure PL Minimum Suction pressure PA Maximum cycle Stall pressure Max operating temperature Media 1-7 bar / 14,5-145 psi 1 bar 180 / min PB = N x PL 60° C Hydraulic oil, water .. Group 2 fluid 97/23/CE Standard Connection Air drive Air pilot Media inlet Media outlet Materials of construction HP section High pressure head EN 1.4404 HP piston EN 1.4404 Check valves inlet components EN 1.4404 Balls EN 1.4034 Springs EN 1.4310 Check valve seats NBR +...

Open the catalog to page 6
AIR DRIVEN LIQUID PUMPS - 7

R SERIES HIGH PRESSURE LOW VOLUME PUMP Model R115 R180 R250 R400 All dimension are for reference only and are subject to change Technical Data Air drive pressure PL Minimum Suction pressure PA Maximum cycle Stall pressure Max operating temperature Media 1-7 bar / 14,5-145 psi 1 bar 180 / min PB = N x PL 60° C Hydraulic oil, water .. Group 2 fluid 97/23/CE Standard Connection Air drive Air pilot Media inlet Media outlet Materials of construction HP section High pressure head EN 1.4418 HP piston EN 1.4418 diamond graphite coated Check valves inlet components EN 1.4542 Balls EN 1.4034 Springs...

Open the catalog to page 7
AIR DRIVEN LIQUID PUMPS - 8

R2 SERIES HIGH PRESSURE LOW VOLUME PUMP Model R2-115 R2-180 R2-250 R2-400 All dimension are for reference only and are subject to change Technical Data Air drive pressure PL Minimum Suction pressure PA Maximum cycle Stall pressure Max operating temperature Media 1-7 bar / 14,5-145 psi 1 bar 180 / min PB = N x PL 60° C Hydraulic oil, water .. Group 2 fluid 97/23/CE Standard Connection Air drive Air pilot Media inlet Media outlet Materials of construction HP section High pressure head EN 1.4418 HP piston EN 1.4418 diamond graphite coated Check valves inlet components EN 1.4542 Balls EN 1.4034...

Open the catalog to page 8
AIR DRIVEN LIQUID PUMPS - 9

STANDARD DELIVERY OPTIONS H-PU seal Head connection straight NBR check valve seal Mounting brackets and pneumatic screws steel zinc plated OPTIONS ON REQUEST - A (head connection 90° ) example R-115-A - U34 (mounting high pressure outlet connection size ¾” -16 unf only for high pressure model) example R-115-U34 - U916 (mounting high pressure outlet connection size 9/16-18 unf only for high pressure model ) example R-115-U916 - V viton check valve seal Other options are available on request

Open the catalog to page 9
AIR DRIVEN LIQUID PUMPS - 10

All graph are for reference only and are subject to change 10

Open the catalog to page 10
AIR DRIVEN LIQUID PUMPS - 11

All graph are for reference only and are subject to change 11

Open the catalog to page 11
AIR DRIVEN LIQUID PUMPS - 12

All graph are for reference only and are subject to change 12

Open the catalog to page 12
AIR DRIVEN LIQUID PUMPS - 13

COMPANY PROFILE MULTI-COUPLING SYSTEM S.r.l. plans and produces hydrodynamic and hydraulic units and plants for the most various industrial fields and for specific applications. Therefore, with new devices, the factory has been able to modern the production cycles getting a better finished product for the national small, medium and big industry, both of builder than users which require a special fluidic technology in the productive process. The factory was born in Legnano but because of its development it was necessary its transferring in Canegrate and following in Villa Cortese in a bigger...

Open the catalog to page 13
AIR DRIVEN LIQUID PUMPS - 14

LIQUID PUMPS SERIES R AND R2 PRESSURE GENERATORS OEM SYSTEMS engineering multipedia.it TEST BENCHES Multi-Coupling System S.r.l. via dell'Artigianato, 8C - 20020 Villa Cortese (MI) - ITALY phone +39 0331 404830 - fax +39 0331 404867 www.multicoupling.com - info@multicoupling.com

Open the catalog to page 14