Selecting the insulation

Selecting the insulation

Selecting the insulation

Product catalog summary
Overview: The document provides guidelines for selecting the appropriate insulation for pipes and fittings in heating systems, service water, and drinking water in buildings. It emphasizes compliance with regulations to prevent heat loss and ensure energy efficiency.
Regulations and Standards: The document references the energy saving decree (EnEV) which mandates insulation thickness for heating and service water pipes with a nominal thermal rating above 4 kW. For drinking water pipes, DIN 1988, Part 2 specifies insulation requirements to prevent heating, condensation, and corrosion.
Insulation Benefits: Besides thermal insulation, the insulating layer reduces structure-borne noise and protects against acoustic bridges through plaster and mortar.
Insulation Thickness Guidelines: The document outlines insulation thickness requirements based on installation circumstances and relevant regulations:
  • Heating and Hot Water: Insulation thickness is determined by the EnEV energy saving decree 2002.
  • Cold Water: Insulation thickness follows DIN 1988-2 standards.
Specific Insulation Products: The document lists various MypoTHERM® products suitable for different applications, including Insulation Tubes, Foam Pipe Insulation, Eccentric Floor Tubes, Insulating Wraps, and Protection Sleeves.
Application Areas: Insulation requirements vary based on the location of pipes, such as unheated rooms, outer walls, shafts, channels, and floor constructions.
Additional Considerations: Even without EnEV requirements, insulation is necessary for corrosion protection, noise avoidance, and vibration reduction in hot water pipes. There is also an obligation to retrofit non-insulated, accessible pipes in older buildings.
See more

Catalog excerpts

Selecting the insulation-1

Insulation © ƒ½„¯ƒÀƒÂƒ¿ – A Concept for Progress and Quality 13/1 08/07 Selecting the insulation Making the right choice According to the applicable regulations, pipes and fittings for heating systems, service water and drinking water in all buildings have to be equipped with thermal insulation. To avoid heat losses, the energy saving decree (EnEV) prescribes the insulation thickness for heating and service water pipes for all heating systems with a nominal thermal rating of more than 4 kW. For drinking water pipes, DIN 1988, Part 2 indicates the corresponding insulation thicknesses for the protection of pipes against heating up, forming of condensation and corrosion. In addition to thermal insulation, the pipe insulating layer also reduces the radiation of structure-borne noise from the pipework and protects the pipes against acoustic bridges through plaster and mortar. The allocation of insulation thickness according to the installation circumstances of the pipes and the relevant regulations is shown in the following overview. Heating (according to the EnEV energy saving decree 2002) Hot water (according to the EnEV energy saving decree 2002) Cold water (according to DIN 1988-2) Insulation thickness 100 % MypoTHERM® Insulation Tube MypoTHERM® Foam Pipe Insulation MypoTHERM® Eccentric Floor Tube In unheated rooms and cellars In outer walls In parts of buildings next to unheated rooms and soil In shafts and channels In parts of buildings between heated rooms if not fitted with isolating valve: e. g. pipe manifolds • •• •• In unheated rooms and cellars In outer walls In parts of buildings next to unheated rooms and soil In shafts and channels In parts of buildings between heated rooms if not fitted with isolating valve: e. g. pipe manifolds • •• •• – Insulation thickness 50 % MypoTHERM® Insulation Tube MypoTHERM® Foam Pipe Insulation MypoTHERM® Eccentric Floor Tube In breakthroughs in walls and ceilings, in crossover regions of pipes, at pipe junctions, at central pipe network distributors In parts of buildings between heated rooms for various users • • In breakthroughs in walls and ceilings, in crossover regions of pipes, at pipe junctions, at central pipe network distributors In parts of buildings between heated rooms for various users • • –

 Open the catalog to page 1
Selecting the insulation-2

Insulation 13/2 © ƒ½„¯ƒÀƒÂƒ¿ – A Concept for Progress and Quality 08/07 Selecting the insulation Heating (according to the EnEV energy saving decree 2002) Hot water (according to the EnEV energy saving decree 2002) Cold water (according to DIN 1988-2) Insulation thickness 13 mm MypoTHERM® Insulation Tube MypoTHERM® Foam Pipe Insulation – – In channels, in wall cutouts, on concrete ceilings next to hot water pipes • MypoTHERM® Eccentric Floor Tube Pipes in floor constructions between heated rooms for various users • Pipes in floor constructions between heated rooms for various users • – Insulation...

 Open the catalog to page 2
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.