Fire Protection
7Pages

{{requestButtons}}

Catalog excerpts

Fire Protection - 1

Fire Protection © ƒ½„¯ƒÀƒÂƒ¿ – A Concept for Progress and Quality 2/1 08/07 Fire Protection in Building Technology Constructional fire protection is playing an increasing important role in house and building technology. Increasingly complex piping systems and with that rising fire load risks are an increasing challenge to planning, design and installation of piping systems. This applies especially in the case of buildings for special purposes such as hospitals, old people's homes, shopping centres and schools where fire protection measures are indispensable. Escape and rescue routes or wall and ceiling penetrations for pipes are important areas where the challenge is to fulfil and combine the demands of constructional fire protection such as the minimum required duration of fire resistance as well as vibration control and thermal insulation. The specifications for building fire protection are given by, among others, the German Model Building Code (MBO), the German State Building Codes (LBO), DIN 4102, the German Pipe Systems Guideline LAR (MLAR) but also the DIN 4109 standard for vibration control considerations and the German Energy Saving Regulation (EnEV) in the area of thermal insulation. The Situation The Fire Protection Requirement according to LAR The following requirements are defined for fastenings in the region above self-supporting, fire-protecting false ceilings in terms of fire duration resistance: Fire resistance duration F30 in the region between ceiling and suspended fire-protection false ceiling Fire-proof fastenings for piping systems in escape and rescue routes Fastening to approved plugs and anchors made of steel with proof of fire protection Proof of stability and deformation of support systems by fire testing • • • • Fire-Tested MÜPRO Attachment Systems The use of fire-tested MÜPRO attachment systems in combination with a proper fire-protection design of the fixture construction creates a system that completely meets the high demands of a fire resistant attachment system as laid down in DIN 4102 and the LAR. The modular spectrum of fire-tested MÜPRO products allows you to build up a comprehensive set of of fireprotected attachment solutions. Our application technology team provides competent support in the planning and design of fixture solutions. The Challenge The Solution Fire-Tested MÜPRO Pipe Support Systems F30 false ceiling with General Construction Supervision Test Certificate (ABP) for fire exposure from above and below

Open the catalog to page 1
Fire Protection - 3

Fire Protection © ƒ½„¯ƒÀƒÂƒ¿ – A Concept for Progress and Quality 2/3 08/07 Plugs Product Size Type Fire Resistance MÜPRO Steel Anchor M10 M12 M16 galvanised V4A stainless steel F30–F120 Catalogue Section 9 MÜPRO Through Anchor M10 M12 M16 galvanised V4A stainless steel F30–F120 Catalogue Section 9 MÜPRO Heavy-Duty Anchor BZ M10 M12 M16 galvanised V4A stainless steel F30–F120 Catalogue Section 9 MÜPRO Hexagon Screw for Concrete M10 M12* galvanised V4A stainless steel* F30–F120 Catalogue Section 9 MÜPRO Injection Anchor M8 M10 M12 galvanised V4A stainless steel F30–F120 Catalogue Section 9 *...

Open the catalog to page 3
Fire Protection - 4

Fire Protection 2/4 © ƒ½„¯ƒÀƒÂƒ¿ – A Concept for Progress and Quality 08/07 MÜPRO products for the attachment of sprinkler systems Minimum requirements for supports in compliance with VdS Guideline 2092/CEA 4001 Nominal diameter [mm] Minimum load-bearing capacity at 20 °C [kg] Minimum cross-section area [mm2] Thread DN 50 200 30 M8 50 < DN 100 350 50 M10 100 < DN 150 500 70 M12 150 < DN 200 850 125 M16 Pipe Clamps Product designation Size Type Guideline MÜPRO Single Bossed Clamp, heavy-duty version without lining For pipe outer diameter from3/8" to 2", M8 from 70.0 mm to 4", M10 from 125.0...

Open the catalog to page 4
Fire Protection - 5

Fire Protection © ƒ½„¯ƒÀƒÂƒ¿ – A Concept for Progress and Quality 2/5 08/07 Anchor Plugs (continued) Product designation Size Type Guideline MÜPRO Hollow-core Slab Ceiling Anchor M8 M10 M12 galvanised VdS 2100 Catalogue Section Anchor Plugs MÜPRO Gas Concrete Under Cut Anchor M8 M10 galvanised VdS 2100 Catalogue Section Anchor Plugs Components for pipe suspensions Product designation Size Type Guideline MÜPRO Trapezoidal Sheet Hangers - with welded-on nut - with clearance hole - with adjusting nut M8 M10 galvanised VdS 2100 Catalogue Section Ventilation MÜPRO Girder Clamp M8 M10 M12...

Open the catalog to page 5
Fire Protection - 6

Fire Protection 2/6 © ƒ½„¯ƒÀƒÂƒ¿ – A Concept for Progress and Quality 08/07 MÜPRO products for the attachment of APPROVED sprinkler systems Minimum requirements for supports in compliance with FM Guidelines Classes 1951, 1952 and 1953 Nominal diameter [mm] [inch] Thread 20 DN 100 3/4–4 M8 125 DN 200 5–8 M10 250 DN 300 10–12 M12 Pipe Clamps Product designation Size Type Guideline MÜPRO Single Bossed Clamp, heavy-duty version without lining For pipe outer diameter from 3/4" to 6" Connection thread M10 and M12 galvanised FM 1951 Catalogue Section Pipe Clamps MÜPRO Filbow Clamp with Knurled Nut...

Open the catalog to page 6