Overview: This document is a technical data sheet for the ECD-H 10 lateral
valve, a 2/2 way valve designed for specific media and application requirements. It highlights standard and optional specifications, emphasizing the importance of precise order specifications to ensure correct valve design.
Specifications:- Pressure Range: 0-200 bar
- Orifice: DN 10 mm
- Connection: Thread
- Function: Direct acting, normally closed (NC) or normally open (NO)
- Design: Pressure balanced with spring return
- Body Materials: Brass, stainless steel
- Seal Materials: Synthetic resin on metal, NBR, PTFE, FPM, CR, EPDM
General Specifications:- Ports: ECD-H threads G 3/8
- Pressure Range: 0-200 bar (NC), 0-150 bar (NO)
- Kv Value: 1.5 m³/h
- Vacuum Leak Rate: < 10-6 mbar•l•s-1
- Media: Gaseous or liquid, abrasive media
- Switching Cycles: 100 per minute
- Switching Time: Opening 250 ms, Closing 110 ms
- Media Temperature: -20 to +100°C (DC), -20 to +160°C (AC)
- Ambient Temperature: -20 to +60°C
- Weight: 6.0 kg
Electrical Specifications:- Nominal Voltage: 24 V DC, 230 V AC (40-60 Hz)
- Insulation Rating: H 180°C
- Protection: IP65
- Connection: Plug according to DIN EN 175301-803
- Current Consumption: 24 V DC 2.64 A, 230 V AC 0.30 A
Additional Features:- Manual override
- Inductive limit switches
- Explosion proof options
Important Notes: The document stresses the importance of complete and precise application specifications to avoid incorrect valve design. It also notes that the application-specific layout may require modifications to materials and seal arrangements.