CAPACITANCE PROBES - Special Push-Pull
1 / 5Pages

Catalog excerpts

CAPACITANCE PROBES - Special Push-Pull - 1

A worldwide leader in precision measurement solutions Capacitance Sensors for Ungrounded Targets or Poorly Grounded Targets PUSH/PULL PROBES TWO HIGH PRECISION SENSORS BUILT INTO ONE BODY

Open the catalog to page 1
CAPACITANCE PROBES - Special Push-Pull - 2

Capacitance Technology: Standard capacitive sensors require the target to be electrically grounded. Current flows from the probe face to the target and back to the amplifier to complete the circuit. The capacitance between probe and target is proportional to the distance and converted to a 0 - 10V output from the amplifier. The measurement of electrically grounded targets can be, however, affected by changes in the electrical conductivity or ground path of the target. Standard Capacitance Sensor Ground Shell Guard Sensing Area TARGET GROUND Ground Return Unique Push/Pull Technology: Two...

Open the catalog to page 2
CAPACITANCE PROBES - Special Push-Pull - 3

11.58 mm (0.456 inch) 20 mm (0.787 inch) 100 mm (3.937 inch) Spot Size 11.58 mm (0.456 inch) 16 mm (0.63 inch) 100 mm (3.937 inch) Spot Size Range Extension Range Extension 9.45 mm (0.372 inch) 14.8 mm (0.583 inch) 34.04 mm (1.34 inch) Spot Size 7.11 mm (0.28 inch) 16 mm (0.63 inch) 50 mm (1.969 inch) Spot Size Range Extension Probe Connector Types: (Ground shell must be grounded to amplifier for proper performance) ILA Integrated Lead Axial ILR Integrated Lead Radial

Open the catalog to page 3
CAPACITANCE PROBES - Special Push-Pull - 4

E 7.42 mm (0.292 inch) D 10.26 mm (0.404 inch) L 31.75 mm (1.25 inch) Spot Size Range Extension E 10.26 mm (0.404 inch) D 13.97 mm (0.55 inch) L 31.75 mm (1.25 inch) Spot Size Range Extension E 12.83 mm (0.505 inch) D 19.05 mm (0.75 inch) L 31.75 mm (1.25 inch) Spot Size Range Extension E 16.15 mm (0.636 inch) D 22.96 mm (0.904 inch) L 31.75 mm (1.25 inch) Spot Size Probe Connector: (Ground shell must be grounded to amplifier for proper performance) ILA Integrated Lead Axial

Open the catalog to page 4
CAPACITANCE PROBES - Special Push-Pull - 5

Push/Pull Probe Specifications Reference Range Spot Size Standard Push/Pull probes are operated at 5X range extension with AccumeasureTM 500 capacitance modular rack systems and AS-562 OEM Boards. Compatible with the following MTI Capacitance Amplifiers Analog Output Benchtop Capacitance Modular System Analog Output Capacitance OEM Board The FS-2 is an adjustable fixture to support and position probes over the target being measured. The system consists of a probe clamp, 2 positioning arms, magnetic base, c-clamp base and a micrometer with a 7mm (0.28") travel. The probe clamp holds probes...

Open the catalog to page 5

All MTI Instruments catalogs and technical brochures

  1. 1510A

    2 Pages

  2. PBS-4100+

    6 Pages

  3. MICROTRAK 3

    4 Pages

  4. PBS-4100R+

    8 Pages

  5. PV Series

    6 Pages

  6. 1510A

    6 Pages

  7. 42CA

    1 Pages

  8. 41CA

    1 Pages

  9. 45CA

    1 Pages

  10. TSC-4800A

    6 Pages

Archived catalogs

  1. APEX SERIES

    2 Pages

  2. TSC-4100R

    1 Pages