ACCUMEASURE CAPACITANCE PROBES - FOR DIGITAL ACCUMEASURE AMPLIFIER
5Pages

{{requestButtons}}

Catalog excerpts

ACCUMEASURE CAPACITANCE PROBES - FOR DIGITAL ACCUMEASURE AMPLIFIER - 1

A worldwide leader in precision measurement solutions ACCUMEASURE Capacitance Probes TM Standard and Custom Capacitance Probes Available

Open the catalog to page 1
ACCUMEASURE CAPACITANCE PROBES - FOR DIGITAL ACCUMEASURE AMPLIFIER - 2

An SMA connector is built in to the probe. The cable is connected to CONNECTOR TYPE RADIAL the capacitive sensor with a connector and it exits the probe radially. SMA CONNECTOR INTEGRAL LEAD RADIAL RADIAL PROBE MOUNTING SIDE VIEW The cable is low-noise highly flexible silicone integral to the ILR probe and exits the probe radially. BOTTOM VIEW CONNECTOR TYPE AXIAL The cable is connected to the CTA capacitive sensor with a connector and it exits the probe axially. INTEGRAL LEAD AXIAL AXIAL PROBE MOUNTING SIDE VIEW The cable is low-noise highly flexible silicone integral to the ILA probe and...

Open the catalog to page 2
ACCUMEASURE CAPACITANCE PROBES - FOR DIGITAL ACCUMEASURE AMPLIFIER - 3

PRODUCT CODE PRODUCT CODE PRODUCT CODE PRODUCT CODE PRODUCT CODE

Open the catalog to page 3
ACCUMEASURE CAPACITANCE PROBES - FOR DIGITAL ACCUMEASURE AMPLIFIER - 4

PRODUCT CODE PRODUCT CODE PANCAKE SQUARE RADIAL PROBES PRODUCT CODE PRODUCT NUMBER Range Min. Range Resolution at 10Hz RMS Max Range Extension1 Resolution at 5kHz RMS E L W T Hole Information nm µi mm Inch mm Inch mm Inch mm Inch

Open the catalog to page 4
ACCUMEASURE CAPACITANCE PROBES - FOR DIGITAL ACCUMEASURE AMPLIFIER - 5

Probe Recommended Stand-off Ranges Probe Specifications Cable and Probe Temperature Rating: Connector Temperature Rating: 1 Accuracy : Probe and Cable Interchangeability: Pressure Rating Standard: Material: -130°C (-202°F) to 200°C (392°F). Cryogenic and higher temperature probes are available up to 1200°C - consult MTI Factory. A BNC to SMA adapter is required -65°C (-85°F) to 85°C(185°F) ±0.01% FSR or better, of range when probe and amplifier are calibrated to a known standard at x1 range extension. Accurate to within ± 0.2% at X1 range extension without recalibration 1400kPa (200 psig)...

Open the catalog to page 5

All MTI Instruments catalogs and technical brochures

  1. 1510A

    2 Pages

  2. PBS-4100+

    6 Pages

  3. MICROTRAK 3

    4 Pages

  4. PBS-4100R+

    8 Pages

  5. PV Series

    6 Pages

  6. 1510A

    6 Pages

  7. 42CA

    1 Pages

  8. 41CA

    1 Pages

  9. 45CA

    1 Pages

  10. TSC-4800A

    6 Pages

Archived catalogs

  1. APEX SERIES

    2 Pages

  2. TSC-4100R

    1 Pages