Overview: The HPDry refrigeration dryers are designed for high-pressure applications up to 50 bar(g), with nominal air flows ranging from 1.46 to 119 m3/min. These dryers are part of MTA's comprehensive range for high-pressure needs, offering significant energy savings and operational flexibility.
Key Features:
  • Energy Efficiency: HPDry operates only when necessary, cycling on and off based on air flow and ambient conditions, achieving up to 80% energy savings compared to traditional dryers.
  • Flexibility: Available in both air-cooled and water-cooled versions, with options for 50 Hz and 60 Hz, and UL listing. Special approvals are available upon request.
  • Microprocessor Control: Automatic adaptation to operating conditions with user-friendly digital controls displaying main parameters and alerts.
  • Ease of Use: Front access to major components and automatic cycling reduce space requirements and simplify operation.
  • Optimum Dew Points: Thermal storage buffers sudden load demands, preventing dew point spikes, with stainless steel demisters ensuring effective separation.
Technical Specifications:
  • Air Circuit: Comprises two shell & tube exchangers for air-to-air and water/glycol-to-air sections, with a large buffer tank and circulating pump.
  • Refrigeration Circuit: Operates only as needed, reducing energy consumption and maintaining constant dew points.
  • Materials and Design: Stainless steel air-side tubes and a simple refrigeration circuit enhance reliability and ease of use.
Additional Components:
  • Condensate Drains: Available in mechanical zero-loss, electronic zero-loss, and timed configurations.
  • Air Receivers: Complements the compressed air network.
  • Filters & Separators: PureTec filters and PureSep separators for pressures up to 250 barg, with four filtration grades.
  • Adsorption Dryers: DryXtreme range for extremely low dew points, available in heatless and heat regenerated configurations.
  • Aftercoolers: CoolPro air and water-cooled aftercoolers for high-pressure applications.
Correction Factors: Tables provide correction factors for pressure dew point, working pressure, air inlet temperature, and ambient temperature to guide accurate selection.
Model Specifications: Detailed specifications for various models, including nominal air flow, absorbed power, air connections, dimensions, and weight.
Compliance and Certification: MTA products comply with European safety directives and are ISO9001 certified, ensuring customer satisfaction.
Contact Information: MTA is represented in over 80 countries, with contact details for offices in Italy, France, Germany, Spain, USA, and Australasia.
See more

Catalog excerpts

HPDry-1

HPDry Refrigeration dryers for 50 bar(g) Nominal air flow 1,46 - 119 m3/min. Purifying your compressed air, increasing your efficiency.

 Open the catalog to page 1
HPDry-2

HPDry has been specifically designed for the needs of the high pressure dryer User, offering working pressures of up to 50 barg. The extremely reliable design concept ensures that HPDry operates perfectly at all times and in all conditions. HPDry automatically adopts its operation to the air flow and ambient conditions, offering energy savings of up to 80% compared with traditional dryers. HPDry forms part of a complete range of MTA products for higher pressures, ensuring all User needs are perfectly satisfied. High energy savings Microprocessor control Flexible to your needs HPDry only operates...

 Open the catalog to page 2
HPDry-3

Unique air circuit How it works: HPDry’s air circuit is made up of two shell & tube exchangers, one for the air-to-air section, the second for the water/glycol-to-air section. The auxiliary water/glycol circuit features a large buffer tank, which acts as a thermal storage, and a circulating pump. The chilled water/glycol mixture circulates through the shell & tube exchanger, cooling the air to the dew point temperature. When the temperature of the water/glycol mixture increases beyond a set value the refrigeration circuit switches on to replenish the buffer tank, switching off again once the...

 Open the catalog to page 3
HPDry-4

Nominal absorbed power (*) (kW) (*) Data refers to the following working conditions: air FAD 20 °C / 1bar A, pressure 40 bar(g), ambient temperature 25 °C, air inlet temperature 35 °C, pressure dew point 3 °C, according to ISO 8573.1 standards. DE dimensions refer to version with iDRAIN. Weights are net (without packing). The refrigerant used is R134a (DE HP) and R410A (HPD). Maximum working pressure 50 bar(g); maximum inlet temperature 70 °C (DE HP) and 65 °C (HPD). Power supply: 230V ±10% / 1Ph / 50Hz (DE015HP-095HP); 400V ±10% / 3Ph / 50Hz (DE170HP-235HP and all HPD models); 60Hz available...

 Open the catalog to page 4

All MTA S.p.A catalogs and technical brochures

  1. DE X - Flyer

    2  Pages

  2. ARIES G

    2  Pages

  3. OCEAN TECH ME

    2  Pages

  4. AQUARIUS G ME

    2  Pages

  5. CYGNUS TECH

    2  Pages

  6. EnerDyer

    4  Pages

  7. PureTec

    6  Pages

  8. LiquiPure

    2  Pages

  9. LiquiPro

    2  Pages

  10. DE iTECH

    8  Pages

  11. CoolPro

    6  Pages

  12. ETM DM

    8  Pages

  13. DE ETM

    8  Pages

  14. HOCEAN TECH

    2  Pages

  15. HTAURUS TECH

    2  Pages

  16. HCYGNUS TECH

    2  Pages

  17. iHCYGNUS TECH

    2  Pages

  18. HARIES TECH

    2  Pages

  19. HAEevo TECH

    2  Pages

  20. TWEevo TECH

    2  Pages

  21. AQUARIUS G

    2  Pages

  22. NEPTUNE TECH

    2  Pages

  23. TAURUS G

    2  Pages

  24. TAURUS TECH

    2  Pages

  25. PHOENIX G

    2  Pages

  26. iPHOENIX G

    2  Pages

  27. ARIEST TECH 2

    2  Pages

  28. TAEevo LWT

    2  Pages

  29. TAEevo TECH

    2  Pages

  30. TAE N Mini

    4  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.