1. Catalogs
  2. MPL
  3. Serial PC/104-Plus card with RS232, RS422/ RS485 ports

Serial PC/104-Plus card with RS232, RS422/ RS485 ports

Serial PC/104-Plus card with RS232, RS422/ RS485 ports

Serial PC/104-Plus card with RS232, RS422/ RS485 ports

Product catalog summary
Overview
The document provides technical specifications and features of the Octal Serial Communication Interface (OSCI) board family, designed by MPL AG. These boards offer up to eight serial lines on a single PC/104-Plus module, with selectable interface modes for RS232 or RS485/422.
Specifications
  • Interface Options: RS232 or RS485/422, with optional galvanic isolation on up to two ports (500 Vrms).
  • Baud Rates: Standard up to 250 kBaud, optional RS485/422 up to 6.25 Mbaud with 60V fail-safe.
  • Temperature Range: Standard -20°C to 70°C, optional -40°C to 85°C.
  • Power: Operates on 5V input power, with typical consumption of 0.7 W for OSCI-8MIX.
  • Physical Dimensions: 90.2 x 95.9 x 11 mm, weighing 90 g.
Features
  • Freely selectable ports for RS232 or RS485/422.
  • Extended temperature options for harsh environments.
  • Compatible with multiple operating systems including Windows NT, 2000, XP, Linux, VxWorks, and QNX.
Applications
The OSCI boards are ideal for industrial solutions requiring multiple serial ports, suitable for rugged and challenging environments.
Additional MPL Products
  • LAN104: Ethernet modules.
  • SPIDERLAN: Ethernet-Switch modules.
  • PATI: Analog and Timer-IO module.
  • PCCARD: PCMCIA adapter.
  • IDE2CF / IDE2PCC: IDE to CompactFlash or PC Card adapter.
Contact Information
MPL AG, Täfernstrasse 20, CH-5405 Baden-Dättwil, Switzerland. Email: [email protected], Website: www.mpl.ch
See more

Catalog excerpts

Serial PC/104-Plus card with RS232, RS422/ RS485 ports-1

4 or 8 x RS232/RS485/RS422 on a single PC/104-Plus Module General Description The Octal Serial Communication Interface (OSCI) board family provides on a single PC/104-Plus module up to eight serial lines. The interface mode of all eight ports are freely selectable either for RS232 or RS485/422. The configuration of all ports is done via software and can be changed at any time. All interfaces work with standard baudrates up to 250kBaud. Optional the RS485/422 interfaces are available with up to 6.25Mbaud and 60V fail safe. Further more galvanic isolation (500Vrms) on up to two RS485/422 ports is available. All serial interfaces are accessible on 2.54mm headers and allow an easy connection to standard serial DSUB-9 connectors. OSCI Specialties ■ Up to eight serial lines ■ All ports freely selectable as RS232 or RS485/422 ■ Galvanic isolation on up to two ports available (500 Vrms) ■ Optional: RS485/422 with up to 6.25Mbaud and 60V fail safe ■ Extended temperature option –40°C to +85°C ■ Drivers are freely available for Windows NT, 2000, XP, Linux and VxWorks, QNX These features make OSCI to the ideal expansion for any industrial solution where you need many serial RS232 and/or RS485/422 ports. The OSCI can be used in any embedded system independent whether it is being used in a rugged, hot or other difficult en- Cable kits with DSUB-9 and/or screw terminal block are available from stock. vironment. MPL has the solution you need For further customer specific versions please contact MPL. and you looked for.

 Open the catalog to page 1
Serial PC/104-Plus card with RS232, RS422/ RS485 ports-2

Technical Features OSCI Board Key Data RS232 Full modem interfaces RS485 2-wire half-duplex interfaces RS422 4-wire full-duplex interfaces Galvanic isolation on up to two RS485/422 ports Host Interface PC/104-Plus compliant PCI specification revision 2.3 compliant Power Runs with 5V input power only Physical / Power Size (length x width x height) Weight Power Power consumption Temperature Range Humidity 90.2 x 95.9 x 11 mm 3.550 x 3.775 x 0.435 inch 90 g / 0.2 lbs +5 VDC ± 5% Typically 0.7 W -20°C up to 70°C 5% - 95% non condensing up to 250 kBaud up to 250 kBaud optional up to 6.25 Mbaud up...

 Open the catalog to page 2
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.