1. Catalogs
  2. MP Filtri
  3. LMS/LDS Series

LMS/LDS Series

LMS/LDS Series
1 / 17 PagesView full catalog

LMS/LDS Series

Product catalog summary
Introduction
This document serves as a comprehensive guide for selecting the appropriate bell-housing and drive coupling for IEC electric motors ranging from size 100 to 315. It covers specifications, procedures, and recommendations for installation and noise reduction.

Specifications
The guide provides sizing information based on motor power, size, manufacturer, and pump type. It includes specific codes and dimensions for motor sizes like LMC250 and LMS250, with detailed drilling codes and spigot hole dimensions.

Procedures
  • Bell-Housing Length Calculation: Ensure the bell-housing length is at least 135.5 mm.
  • Coupling Selection: Use MP Filtri's software for automatic calculation and selection of components.
  • Installation: Follow guidelines for horizontal mounting on oil tank lids or machines, using flexible pipelines and anti-vibration devices.

Standards and Recommendations
Recommendations include using low noise bell-housings, ensuring correct installation to prevent noise, and following recommended tightening torques for motor/pump fixing.

Materials and Compatibility
Bell-housing components are made from pressure die-cast aluminium alloy, with a damping ring of vulcanized aluminium and NBR 75 Shore A, compatible with various fluids per ISO 6743/4 standards.

Noise Considerations
The document emphasizes minimizing noise emissions through low noise bell-housings and proper installation techniques.

Conclusion
For optimal performance, avoid rigid connections between motor and pump units to prevent vibration and noise. Detailed guidelines and specifications are provided for correct selection and installation.

General Information
Technical specifications and guidelines for MP Filtri's bell-housing products are provided, with emphasis on evaluation and approval for specifications outside the provided range.

Bell-Housing Specifications
Various sizes and dimensions are listed, including shaft ends and spigot holes, with weights for each model.

IEC Motor Compatibility
Compatibility with IEC electric motors from size 100 to 315 is outlined, with specific shaft end dimensions.

Configuration and Options
Bell-housings are available in different series and sizes, with options like rotated holes, double sets of holes, and black anodized finishes. Customization is available upon request.

Dimensions and Weights
Tables provide dimensions and weights for bell-housing models, specifying measurements like D1, D2, D3, H1, H2, F, H3, and D6.

Comparative Table
A table guides interchangeability with codes from other manufacturers, noting that not all bell-housings are fully interchangeable.

Safety and Standards
Safety standards, specifically DIN EN 292 part 2, are mentioned regarding protection by plastic threaded plugs on inspection holes.
See more

Catalog excerpts

LMS/LDS Series-1

LMS/LDS series IEC electric motor range from size 100 up to size 315

 Open the catalog to page 1
LMS/LDS Series-2

BELL-HOUSING & COUPLING SIZING A GUIDE TO SELECT THE CORRECT BELL-HOUSING AND DRIVE COUPLING DATA REQUIRED - Electric motor power/motor size - Manufacturer and pump type TO VERIFY: 1 - Pump and motor shaft dimensions (see electric motor data sheet) 2 - Shaft and flange pump (see pump data sheet) Example: - Electric motor 2.2 kW - size 100-112 - Atos pump code PFE31 - Shaft 1 IEC Electric motor dimension Hydraulic pump dimension ø19.05 - key 4.76 Case A Solution with monobloc bell-housing series LMC/LDC Bell-Housing’s length calculation Pages 63 ÷ 69 for IEC Electric motor size 100-112 - LMC250...

 Open the catalog to page 2
LMS/LDS Series-3

BELL-HOUSING & COUPLING SIZING A GUIDE TO SELECT THE CORRECT BELL-HOUSING AND DRIVE COUPLING Coupling selection Motor half-coupling (see page 26) For IEC Electric motor size 100/112, the half-coupling is SGEA21M05060FG Spider (see page 31) For SGEA21, EGE2 - EGE2RR (choose spider material on the base of the application, oil, temperature and cycle machine, etc.) Pump half-coupling Choose the drilling code - see pages 18-19 for shaft 19.05 - key 4.76 - code: G01 Pump half-coupling length = BH length - THK Spider - THK Spigot LMC = 138 mm - 60 - 18 - 9.5 = 50.5 mm LMS = 148 mm - 60 - 18 - 9.5 =...

 Open the catalog to page 3
LMS/LDS Series-4

BELL-HOUSING & COUPLING SIZING Step Selection Software Select “BELL-HOUSING & COUPLING” Choose Manufacturer: select “Pump type” and “Pump model” Choose Coupling material Choose nr° of poles of “Electric motors”: select “Electric motors type” and “Elect

 Open the catalog to page 4
LMS/LDS Series-5

BELL-HOUSING & COUPLING SIZING Selection Software Step Push “CLICK HERE TO PROCEED”, then choose best solution for your application. Push “PREVIEW” to download the reports. Complete kit for: -IEC Electric Motor Size 160 -Pump Bosch Rexroth A10VSO45 shaft P Per errori ammissibili di quote senza tolleranze e per altre prescrizioni generali vedi UNI EN 22768-1/1996 - f For the permissible errors on the dimensions without tollerance and for other general specifications . See UNI EN 22768-1/1996 - f DESCRIPTION Monobloc Bellhousing Spider Motor Half Coupling Pump Half Coupling Tav./Sht. di/of Questo...

 Open the catalog to page 5
LMS/LDS Series-6

GENERAL INFORMATION Noise is a particularly pervasive problem so much so that there have been statutory regulations in place now for some years, designed to limit harmful occupational exposure. Many of the machines used in industry today are equipped with oil-hydraulic systems, which happen to be a major source of noise. THEORY AND DEFINITION OF NOISE From a health and hygiene standpoint, noise can be defined as an unpleasant and undesirable sound, or an unpleasant and annoying or intolerable auditory sensation (noise being any sound phenomena that may be accompanied by sensations of disturbance...

 Open the catalog to page 6
LMS/LDS Series-7

ASSEMBLY OF MOTOR AND PUMP UNIT Low noise bell-housing will help to attenuate the transmission of vibrations and the emission of noise generated by the system. Self-evidently, however, the mere adoption of a low noise bell-housing will achieve little unless the motor and pump are correctly installed on the machine or on the tank of the hydraulic power unit. Should be followed in order to achieve best possible results and correct installation: ® MOTOR AND PUMP UNIT MOUNTED HORIZONTALLY ON OIL TANK LID - The suction pipe attached to the pump must be rigid and fitted using a resilient bulkhead flange...

 Open the catalog to page 7
LMS/LDS Series-8

GENERAL INFORMATION PUMP INTERFACE CODES Valid configuration for bell-housing up to ø400 Bell-housing with nr. 2 holes at pump interface, aligned with through holes at motor interface. Spigot hole Bell-housing with nr. 4 holes at pump interface, aligned with thread holes at motor interface. Spigot hole Bell-housing with nr. 2 holes at pump interface + 22.5° compared to through holes at motor interface. Spigot hole Valid configuration for bell-housing from ø450 to ø660 Spigot hole Bell-housing with nr. 4 holes at pump interface + 22.5° compared to thread holes at motor interface.

 Open the catalog to page 8
LMS/LDS Series-11

LMS/LDS series IEC electric motor range from size 100 up to size 315

 Open the catalog to page 11
LMS/LDS Series-12

GENERAL INFORMATION Technical data Bell-Housing - IEC electric motor range from size 100 up to size 315 Materials - Motor base bell-housing: Pressure die-cast aluminium alloy - Pump flange: Pressure die-cast aluminium alloy - Internal ring: Pressure die-cast aluminium alloy - Damping ring: Vulcanized aluminium + NBR 75 Shore A Compatibility with fluids Modular bell-housing components compatible for use with: - Mineral oils types HH-LL-HM-HR-HV-HC, to ISO 6743/4 standard - Water based emulsions types HFAE-HFAS, to ISO 6743/4 standard - Water glycol type HFC, to ISO 6743/4 standard: ask for anodized...

 Open the catalog to page 12
LMS/LDS Series-13

GENERAL INFORMATION LMS/LDS Bell-Housing size

 Open the catalog to page 13
LMS/LDS Series-14

LMS/LDS Designation & Ordering code LMS Configuration example: Configuration example: Bell-Housing series and size Pump interface codes Drain hole + inspection hole Holes rotated through 45° in relation to standard position Double set of hole Black anodized finish Clearance holes at motor interface Customer specification LDS Bell-Housing series and size Pump interface codes Drain hole + inspection hole Holes rotated through 45° in relation to standard position Double set of hole Black anodized finish Clearance holes at motor interface Customer specification Note: - Bell-housings with DI options...

 Open the catalog to page 14
LMS/LDS Series-15

IEC - Electric motors Motor size Shaft end [d x l]

 Open the catalog to page 15
LMS/LDS Series-16

Dimensions IEC - Electric motors Bell-housing Dimensions [mm] On request Spigot hole Weight Motor size Shaft end [d x l] code D1 D2 D3 H1 H2 F P H3 D6 Minimum [mm] [kg]

 Open the catalog to page 16
LMS/LDS Series-17

IEC - Electric motors Motor size Shaft end [d x l] Note: The above table is guideline only. Not all bell-housings are fully interchangeable.

 Open the catalog to page 17

All MP Filtri catalogs and technical brochures

  1. LMC/LDC Series

    17  Pages

  2. LMG Series

    21  Pages

  3. ACCESSORIES

    28  Pages

  4. BELL HOUSING

    72  Pages

  5. COUPLINGS

    46  Pages

  6. SPIN-ON FILTERS

    76  Pages

  7. Suction Filters

    72  Pages

  8. Return Filters

    230  Pages

  9. FHD - DUPLEX

    17  Pages

  10. FHB - MANIFOLD

    16  Pages

  11. FHM - MANIFOLD

    21  Pages

  12. FHP

    19  Pages

  13. FMP

    14  Pages

  14. Spin-On Filter

    78  Pages

  15. Stainless Steel

    20  Pages

  16. LMP 124

    6  Pages

  17. MRSX

    12  Pages

  18. MSH

    4  Pages

  19. MPS

    8  Pages

  20. LMP 952 - 954

    6  Pages

  21. LMP 900 - 901

    4  Pages

  22. LMP MULTIPORT

    8  Pages

  23. FMP 039

    4  Pages

  24. SF2 250 - 350

    4  Pages

  25. FRI

    10  Pages

  26. MPI

    8  Pages

  27. MPH

    18  Pages

  28. MPT

    15  Pages

  29. MST

    4  Pages

  30. STR

    4  Pages

  31. RF2

    4  Pages

  32. MPF

    20  Pages

  33. LMP 400 - 430

    10  Pages

  34. LMP 210

    5  Pages

  35. FAS

    4  Pages

  36. SF2 500

    12  Pages

  37. SF2 250

    8  Pages

  38. SA - SAP

    10  Pages

  39. STR

    4  Pages

  40. Pressure filters

    116  Pages

  41. In-line filters

    108  Pages

  42. Accessories

    68  Pages

  43. Catalogue

    19  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.