Catalog excerpts
Te c h n i c a l d a t a Filter housing (Materials) • Head: Anodised Aluminium • Housings compatible with: Mineral oils, synthetic fluids, aqueous emulsions, water and glycol • Housing: Anodised Aluminium • Bypass valve: Steel Pressure LMP 400 length: 2 - 3 - 4 • Working pressure: 60 bar (6 MPa) • The filter elements are compatible with: Mineral oils, synthetic fluids. Aqueous emulsions, water and glycol (series W required). • NBR seals series A, compatible with: Mineral oils, synthetic fluids, aqueous emulsions and water and glycol. • Pulsed pressure fatigue test: 1.000.000 cycles with...
Open the catalog to page 2Option P02 “Internal tube for reduced flow rate” is recommended for flow rate values below 100/150 I/min. The use of option P02 makes it easier to fill the housing with the operating fluid. Recommended maximum flow rate Recommended maximum flow rate for filters installed on lubrication lines, return or in-line filters is defined by the maximum oil velocity in the connections. For filters mounted on Off-Line lines the maximum recommended flow rate is defined by the pressure drop of the filter element. Filter for pressurised lubrication, max. oil velocity 2.5 m/sec. Return or in-line filter,...
Open the catalog to page 3Fixing holes and surface C Fixing holes and surface A - Breather plug - G 3/8” - A/F 8 B - Indicator port - Plug T2 - A/F 30 C - Bypass valve - A/F 17 D - Oil drain plug - G 3/8” - A/F 8 Thread IN - OUT connections Flanged IN - OUT connections LMP 400 - 401 Length Filter
Open the catalog to page 4P02 maintenance option from housing base P01 standard maintenance from head H1 Fixing holes and surface C Fixing holes and surface Length Filter B - Indicator connection - Plug T2 - A/F 30
Open the catalog to page 5Fixing holes and surface Fixing holes and surface A - Breather plug - G 3/8” - A/F 8 B - Indicator port - Plug T2 - A/F 30 D - Oil drain plug - G 3/8” - A/F 8 Thread IN - OUT connections Flanged IN - OUT connections LMP 430 - 431 Length Filter
Open the catalog to page 6Filter Element Filter element O-Ring Bonded seal for indicator Breather plug By-pass plug O-Ring Indicator connection plug Filter assembly
Open the catalog to page 7Filter assembly Filter Element Filter element O-Ring Bonded seal for indicator Breather plug for indicator By-pass plug O-Ring Indicator connection plug Housing spigot
Open the catalog to page 8Filter assembly Filter Element Filter element O-Ring Breather plug Indicator connection plug Housing spigot Tube assembly Spigot no by-pass 01044108 Spigot with by-pass 02001414 Length 5 - 02025041 Length 6 - 02025042
Open the catalog to page 9Filter assembly Filter element 6 - Filter element Filter element Inorganic microfibre Inorganic microfibre 6 μ Inorganic microfibre 10 μ Wire mesh Resin impregnated paper Nominal Filtration Nominal Filtration Without by-pass With bypass With by-pass Resin impregnated paper Wire mesh Wire mesh Absolute filtration 7 - Max filter element differential pressure N Opening pressure: on request NBR (Compatible with fluid HFA, HFB, HFC) Customer request Maintenance from base housing (only length 5 and 6) With internal tube for reduced flow rate MP Filtri standard Customer request Flanged Type...
Open the catalog to page 10All MP Filtri catalogs and technical brochures
-
MULTI-COMPONENTS
31 Pages
-
LMS/LDS Series
17 Pages
-
LMC/LDC Series
17 Pages
-
LMG Series
21 Pages
-
ACCESSORIES
28 Pages
-
BELL HOUSING
72 Pages
-
CLOGGING INDICATORS
24 Pages
-
COUPLINGS
46 Pages
-
CONTAMINATION CONTROL SOLUTIONS
140 Pages
-
Return / Suction Filters
76 Pages
-
SPIN-ON FILTERS
76 Pages
-
Stainless Steel Filters
102 Pages
-
Low & Medium Pressure Filters
168 Pages
-
High Pressure Filters
160 Pages
-
Suction Filters
72 Pages
-
Return Filters
230 Pages
-
FHD - DUPLEX
17 Pages
-
FHF 325 - MANIFOLD
14 Pages
-
FHB - MANIFOLD
16 Pages
-
FHM - MANIFOLD
21 Pages
-
FHP
19 Pages
-
FMP
14 Pages
-
Spin-On Filter
78 Pages
-
Stainless Steel
20 Pages
-
LMP 124
6 Pages
-
MRSX
12 Pages
-
MSH
4 Pages
-
CS - CG - CW - CT
2 Pages
-
MPS
8 Pages
-
LMP 952 - 954
6 Pages
-
LMP 900 - 901
4 Pages
-
LMD 400 - 401 - 431 DUPLEX
8 Pages
-
LMP MULTIPORT
8 Pages
-
FMM 050 - FHA 051
6 Pages
-
FMP 039
4 Pages
-
Clogging Indicators
26 Pages
-
SF2 250 - 350
4 Pages
-
Suction Strainer
7 Pages
-
FRI
10 Pages
-
MPI
8 Pages
-
MPH
18 Pages
-
MPT
15 Pages
-
filter element CH
1 Pages
-
MST
4 Pages
-
STR
4 Pages
-
RF2
4 Pages
-
MPF
20 Pages
-
LMP 210
5 Pages
-
LMP 110-120-123 MULTIPORT
25 Pages
-
FAS
4 Pages
-
SF2 500
12 Pages
-
SF2 250
8 Pages
-
Structural components
78 Pages
-
SA - SAP
10 Pages
-
STR
4 Pages
-
Condition monitoring products
14 Pages
-
Pressure filters
116 Pages
-
In-line filters
108 Pages
-
Structural components
64 Pages
-
Accessories
68 Pages
-
Catalogue
19 Pages