Catalog excerpts
Maximum pressure 80 bar Flow rates to 160 l/min 10
Open the catalog to page 1Te c h n i c a l d a t a Filter housing (Materials) • NBR seals series A, compatible with: Mineral oils, synthetic fluids, aqueous emulsions and water and glycol. • Head: Aluminium • Housing: Cataphoresis Painting • FPM seals series V, compatible with: Synthetic fluids type HS-HFDR-HFDS-HFDU • Bypass valve: Brass - Aluminium Pressure Recommended maximum flow rate => see page 35 LMP 110 length: 1 - 2 - 3 - 4 • Working pressure: 80 bar (8 MPa) Filter Element Area Filter element in stainless steel mesh • Pulse pressure fatigue test: 1.000.000 cycles with pressure from 0 to 80 bar (8 MPa)...
Open the catalog to page 2Flow rate l/min Flow rate l/min Valves Bypass valve pressure drop Valves Bypass valve pressure drop LMP 110 - LMP 112 - LMP 116 - 119 Flow rate l/min 12 Flow rate l/min
Open the catalog to page 3Indicator port B (option) 60,6 Filter fixing holes LMP 110 - 112 - 116 - 118 - 119 B Double filter fixing holes Length Filter
Open the catalog to page 4Indicator port
Open the catalog to page 6Filter element O-Ring for filter element Indicator connection plug Filter assembly
Open the catalog to page 7Or dering infor mation LMP 1 10 - 119 1 Filter assembly Filter element Filter element Inorganic microfibre Inorganic microfibre 6 μ Inorganic microfibre 10 μ Wire mesh Wire mesh Without bypass (excluded LMP 118 - 119) Wire mesh Resin impregnated paper Resin impregnated paper Nominal Filtration With bypass With bypass Opening pressure: on request Nominal Filtration 8 - Max filter element differential pressure NBR (Compatible with fluid HFA, HFB, HFC) DIFFERENTIAL INDICATORS (see page 120) MP Filtri - The filter functions as described in this bulletin are valid exclusively for original MP...
Open the catalog to page 8Maximum pressure 80 bar Flow rates to 200 l/min 18
Open the catalog to page 9Te c h n i c a l d a t a Filter housing (Materials) Filter Element Area • Head: Aluminium Filter element in stainless steel mesh • Housing: Cataphoresis Painting • Bypass valve: Brass - Aluminium • Burst pressure: 380 bar (38 MPa) • Pulse pressure fatigue test: 1.000.000 cycles with pressure from 0 to 80 bar (8 MPa) Temperature • From -25°C to +110°C Bypass valve • Opening pressure 3.5 bar ±10% • Other opening pressures on request. Style LMP 122 Δp Elements type • Series N and W elements: 20 bar • Oil flow from exterior to interior. Filter housings Δp pressure drop The curves are plotted...
Open the catalog to page 10Filter housings Δp pressure drop The curves are plotted utilising mineral oil with density of 0.86 kg/dm3 to ISO 3968. Δp varies proportionally with density. Flow rate l/min D.I. A LMP 123 - Δp Housing with check valve 2 bar setting 16 Cooler Flow rate l/min Valves Bypass valve pressure drop LMP 123 - Δp Housing with check valve 3 bar setting 16 Flow rate l/min 20 Flow rate l/min
Open the catalog to page 11Dimens ions LMP 120 Indicator port Indicator port Length Filter M10 x depth 12 mm M10 x depth 12 mm 3/8” UNC x depth 12 mm 3/8” UNC x depth 12 mm 3/8” UNC x depth 12 mm 3/8” UNC x depth 12 mm
Open the catalog to page 12M10 x depth 12 mm 3/8” UNC x depth 12 mm 3/8” UNC x depth 12 mm
Open the catalog to page 13FILTER Series LMP 120 - 122 - 123 See order table Filter assembly Filter element O-Ring for filter element Indicator connection plug
Open the catalog to page 14Filter assembly Filter element Filter element Without indicator port With indicator port Inorganic microfibre Inorganic microfibre 6 μ Inorganic microfibre 10 μ Without by-pass Wire mesh With bypass With by-pass Wire mesh Wire mesh Resin impregnated paper Resin impregnated paper Opening pressure: on request NBR (Compatible with fluid HFA, HFB, HFC) Nominal Filtration Nominal Filtration 8 - Max filter element differential pressure N 9 - Option 5 - Connection P01 Type DIFFERENTIAL INDICATORS (see page 120) MP Filtri - The filter functions as described in this bulletin are valid exclusively...
Open the catalog to page 15Or deri ng infor mation LMP 1 23 1 Filter assembly Filter element Filter element 2 - Filter length 6 - Indicator port 1 2 Without indicator port With indicator port Check valve 2 bar Check valve 3 bar Inorganic microfibre 6 μ Inorganic microfibre 10 μ Inorganic microfibre 16 μ Inorganic microfibre Type 1 - Without bypass Type 2 - Without bypass G H Resin impregnated paper Nominal Filtration Nominal Filtration Check valve 2 bar Check valve 3 bar Resin impregnated paper Type 2 - With bypass Wire mesh Wire mesh Check valve 2 bar Check valve 3 bar Wire mesh Check valve 2 bar Check valve 3 bar...
Open the catalog to page 16LMP 124 In-Line Suction and Return Filter Maximum pressure 80 bar Flow rates to 160 l/min 26
Open the catalog to page 17Te c h n i c a l d a t a Filter housing (Materials) Filter Element Area • Head: Aluminium Filter element in stainless steel mesh • Housing: Cataphoresis Painting • Bypass valve: Brass - Aluminium • Test pressure: 120 bar (12 MPa) • Burst pressure: 380 bar (38 MPa) • Pulse pressure fatigue test: 1.000.000 cycles with pressure from 0 to 80 bar (8 MPa) Temperature • From -25°C to +110°C Bypass valve • Opening pressure 2.5 bar ±10% • Other opening pressures on request. Filter housings Δp pressure drop The curves are plotted utilising mineral oil with density of 0.86 kg/dm3 to ISO 3968. • Series...
Open the catalog to page 18Flow rate l/min Flow rate l/min Flow rate l/min Flow rate l/min Flow rate l/min Flow rate l/min
Open the catalog to page 19Dimens ions LMP 124 Indicator port
Open the catalog to page 20FILTER Series LMP 124 See order table Filter assembly Filter element O-Ring for filter element Indicator connection plug
Open the catalog to page 21Or deri ng infor mation LMP 1 24 1 Filter assembly Filter element Filter element No Port G 1/8” switch For pressure switch Port G 1/4” For pressure switch Differential indicator port 8 - Max filter element differential pressure Customer request NBR (Compatible with fluid HFA, HFB, HFC) On request DIFFERENTIAL INDICATORS (see page 120) MP Filtri - The filter functions as described in this bulletin are valid exclusively for original MP Filtri filter elements and replacement parts. All rights reserved The data in this publication are purely guideline. MP Filtri reserves the right to make...
Open the catalog to page 23All MP Filtri catalogs and technical brochures
-
MULTI-COMPONENTS
31 Pages
-
LMS/LDS Series
17 Pages
-
LMC/LDC Series
17 Pages
-
LMG Series
21 Pages
-
ACCESSORIES
28 Pages
-
BELL HOUSING
72 Pages
-
CLOGGING INDICATORS
24 Pages
-
COUPLINGS
46 Pages
-
CONTAMINATION CONTROL SOLUTIONS
140 Pages
-
Return / Suction Filters
76 Pages
-
SPIN-ON FILTERS
76 Pages
-
Stainless Steel Filters
102 Pages
-
Low & Medium Pressure Filters
168 Pages
-
High Pressure Filters
160 Pages
-
Suction Filters
72 Pages
-
Return Filters
230 Pages
-
FHD - DUPLEX
17 Pages
-
FHF 325 - MANIFOLD
14 Pages
-
FHB - MANIFOLD
16 Pages
-
FHM - MANIFOLD
21 Pages
-
FHP
19 Pages
-
FMP
14 Pages
-
Spin-On Filter
78 Pages
-
Stainless Steel
20 Pages
-
LMP 124
6 Pages
-
MRSX
12 Pages
-
MSH
4 Pages
-
CS - CG - CW - CT
2 Pages
-
MPS
8 Pages
-
LMP 952 - 954
6 Pages
-
LMP 900 - 901
4 Pages
-
LMD 400 - 401 - 431 DUPLEX
8 Pages
-
LMP MULTIPORT
8 Pages
-
FMM 050 - FHA 051
6 Pages
-
FMP 039
4 Pages
-
Clogging Indicators
26 Pages
-
SF2 250 - 350
4 Pages
-
Suction Strainer
7 Pages
-
FRI
10 Pages
-
MPI
8 Pages
-
MPH
18 Pages
-
MPT
15 Pages
-
filter element CH
1 Pages
-
MST
4 Pages
-
STR
4 Pages
-
RF2
4 Pages
-
MPF
20 Pages
-
LMP 400 - 430
10 Pages
-
LMP 210
5 Pages
-
FAS
4 Pages
-
SF2 500
12 Pages
-
SF2 250
8 Pages
-
Structural components
78 Pages
-
SA - SAP
10 Pages
-
STR
4 Pages
-
Condition monitoring products
14 Pages
-
Pressure filters
116 Pages
-
In-line filters
108 Pages
-
Structural components
64 Pages
-
Accessories
68 Pages
-
Catalogue
19 Pages