Maximum pressure 80 bar Flow rates to 160 l/min 10
Open the catalog to page 1Te c h n i c a l d a t a Filter housing (Materials) • NBR seals series A, compatible with: Mineral oils, synthetic fluids, aqueous emulsions and water and glycol. • Head: Aluminium • Housing: Cataphoresis Painting • FPM seals series V, compatible with: Synthetic fluids type HS-HFDR-HFDS-HFDU • Bypass valve: Brass - Aluminium Pressure Recommended maximum flow rate => see page 35 LMP 110 length: 1 - 2 - 3 - 4 • Working pressure: 80 bar (8 MPa) Filter Element Area Filter element in stainless steel mesh • Pulse pressure fatigue test: 1.000.000 cycles with pressure from 0 to 80 bar (8 MPa) Bypass...
Open the catalog to page 2Flow rate l/min Flow rate l/min Valves Bypass valve pressure drop Valves Bypass valve pressure drop LMP 110 - LMP 112 - LMP 116 - 119 Flow rate l/min 12 Flow rate l/min
Open the catalog to page 3Indicator port B (option) 60,6 Filter fixing holes LMP 110 - 112 - 116 - 118 - 119 B Double filter fixing holes Length Filter
Open the catalog to page 4Indicator port
Open the catalog to page 6Filter element O-Ring for filter element Indicator connection plug Filter assembly
Open the catalog to page 7Or dering infor mation LMP 1 10 - 119 1 Filter assembly Filter element Filter element Inorganic microfibre Inorganic microfibre 6 μ Inorganic microfibre 10 μ Wire mesh Wire mesh Without bypass (excluded LMP 118 - 119) Wire mesh Resin impregnated paper Resin impregnated paper Nominal Filtration With bypass With bypass Opening pressure: on request Nominal Filtration 8 - Max filter element differential pressure NBR (Compatible with fluid HFA, HFB, HFC) DIFFERENTIAL INDICATORS (see page 120) MP Filtri - The filter functions as described in this bulletin are valid exclusively for original MP Filtri...
Open the catalog to page 8Maximum pressure 80 bar Flow rates to 200 l/min 18
Open the catalog to page 9Te c h n i c a l d a t a Filter housing (Materials) Filter Element Area • Head: Aluminium Filter element in stainless steel mesh • Housing: Cataphoresis Painting • Bypass valve: Brass - Aluminium • Burst pressure: 380 bar (38 MPa) • Pulse pressure fatigue test: 1.000.000 cycles with pressure from 0 to 80 bar (8 MPa) Temperature • From -25°C to +110°C Bypass valve • Opening pressure 3.5 bar ±10% • Other opening pressures on request. Style LMP 122 Δp Elements type • Series N and W elements: 20 bar • Oil flow from exterior to interior. Filter housings Δp pressure drop The curves are plotted utilising...
Open the catalog to page 10Filter housings Δp pressure drop The curves are plotted utilising mineral oil with density of 0.86 kg/dm3 to ISO 3968. Δp varies proportionally with density. Flow rate l/min D.I. A LMP 123 - Δp Housing with check valve 2 bar setting 16 Cooler Flow rate l/min Valves Bypass valve pressure drop LMP 123 - Δp Housing with check valve 3 bar setting 16 Flow rate l/min 20 Flow rate l/min
Open the catalog to page 11Dimens ions LMP 120 Indicator port Indicator port Length Filter M10 x depth 12 mm M10 x depth 12 mm 3/8” UNC x depth 12 mm 3/8” UNC x depth 12 mm 3/8” UNC x depth 12 mm 3/8” UNC x depth 12 mm
Open the catalog to page 12M10 x depth 12 mm 3/8” UNC x depth 12 mm 3/8” UNC x depth 12 mm
Open the catalog to page 13FILTER Series LMP 120 - 122 - 123 See order table Filter assembly Filter element O-Ring for filter element Indicator connection plug
Open the catalog to page 14Filter assembly Filter element Filter element Without indicator port With indicator port Inorganic microfibre Inorganic microfibre 6 μ Inorganic microfibre 10 μ Without by-pass Wire mesh With bypass With by-pass Wire mesh Wire mesh Resin impregnated paper Resin impregnated paper Opening pressure: on request NBR (Compatible with fluid HFA, HFB, HFC) Nominal Filtration Nominal Filtration 8 - Max filter element differential pressure N 9 - Option 5 - Connection P01 Type DIFFERENTIAL INDICATORS (see page 120) MP Filtri - The filter functions as described in this bulletin are valid exclusively for...
Open the catalog to page 15Or deri ng infor mation LMP 1 23 1 Filter assembly Filter element Filter element 2 - Filter length 6 - Indicator port 1 2 Without indicator port With indicator port Check valve 2 bar Check valve 3 bar Inorganic microfibre 6 μ Inorganic microfibre 10 μ Inorganic microfibre 16 μ Inorganic microfibre Type 1 - Without bypass Type 2 - Without bypass G H Resin impregnated paper Nominal Filtration Nominal Filtration Check valve 2 bar Check valve 3 bar Resin impregnated paper Type 2 - With bypass Wire mesh Wire mesh Check valve 2 bar Check valve 3 bar Wire mesh Check valve 2 bar Check valve 3 bar Type...
Open the catalog to page 16LMP 124 In-Line Suction and Return Filter Maximum pressure 80 bar Flow rates to 160 l/min 26
Open the catalog to page 17Te c h n i c a l d a t a Filter housing (Materials) Filter Element Area • Head: Aluminium Filter element in stainless steel mesh • Housing: Cataphoresis Painting • Bypass valve: Brass - Aluminium • Test pressure: 120 bar (12 MPa) • Burst pressure: 380 bar (38 MPa) • Pulse pressure fatigue test: 1.000.000 cycles with pressure from 0 to 80 bar (8 MPa) Temperature • From -25°C to +110°C Bypass valve • Opening pressure 2.5 bar ±10% • Other opening pressures on request. Filter housings Δp pressure drop The curves are plotted utilising mineral oil with density of 0.86 kg/dm3 to ISO 3968. • Series N...
Open the catalog to page 18Flow rate l/min Flow rate l/min Flow rate l/min Flow rate l/min Flow rate l/min Flow rate l/min
Open the catalog to page 19Dimens ions LMP 124 Indicator port
Open the catalog to page 20FILTER Series LMP 124 See order table Filter assembly Filter element O-Ring for filter element Indicator connection plug
Open the catalog to page 21Or deri ng infor mation LMP 1 24 1 Filter assembly Filter element Filter element No Port G 1/8” switch For pressure switch Port G 1/4” For pressure switch Differential indicator port 8 - Max filter element differential pressure Customer request NBR (Compatible with fluid HFA, HFB, HFC) On request DIFFERENTIAL INDICATORS (see page 120) MP Filtri - The filter functions as described in this bulletin are valid exclusively for original MP Filtri filter elements and replacement parts. All rights reserved The data in this publication are purely guideline. MP Filtri reserves the right to make changes...
Open the catalog to page 2331 Pages
17 Pages
17 Pages
21 Pages
28 Pages
72 Pages
24 Pages
46 Pages
140 Pages
76 Pages
76 Pages
102 Pages
168 Pages
160 Pages
72 Pages
230 Pages
17 Pages
14 Pages
16 Pages
21 Pages
19 Pages
14 Pages
78 Pages
20 Pages
6 Pages
12 Pages
4 Pages
2 Pages
8 Pages
6 Pages
4 Pages
8 Pages
8 Pages
6 Pages
4 Pages
26 Pages
4 Pages
7 Pages
10 Pages
8 Pages
18 Pages
15 Pages
1 Page
4 Pages
4 Pages
4 Pages
20 Pages
10 Pages
5 Pages
4 Pages
12 Pages
8 Pages
78 Pages
10 Pages
4 Pages
14 Pages
116 Pages
108 Pages
64 Pages
68 Pages
19 Pages