Introduction
This guide offers detailed instructions for selecting the appropriate bell-housing and drive coupling for IEC electric motors sized 63 to 225, covering specifications, installation procedures, and noise reduction strategies.

Specifications
The document specifies dimensions and codes for bell-housings and couplings, such as the LMC250 and LMS250 models, which require specific drilling codes like code 060 for a spigot hole of 82.55 mm and a PCD of 106.4 mm.

Procedures
It provides detailed steps for calculating bell-housing lengths and selecting coupling components, emphasizing that the bell-housing length must meet or exceed the calculated length (e.g., 135.5 mm). Guidance is also given for choosing the correct half-coupling length based on the bell-housing type.

Noise Reduction
The document explains noise theory and the role of bell-housings in noise transmission, recommending low noise bell-housings to reduce vibrations and noise emissions. Proper installation is crucial, with guidelines for mounting on oil tank lids and machines.

Installation Recommendations
Recommendations include using rigid suction pipes with resilient bulkhead flanges, flexible pressure pipelines, and anti-vibration devices to prevent vibration propagation.

Technical Data
Bell-housings are made from pressure die-cast aluminum with galvanized steel center rings and special paper gaskets, compatible with various fluids and operational between -30°C and +80°C.

Conclusion
For optimal performance, the document advises integrating the motor-and-pump unit into the hydraulic system without rigid connections, ensuring proper installation and noise reduction, and provides recommended tightening torques for motor/pump fixing on the bell-housing.
See more

Catalog excerpts

LMG Series-1

LMG series IEC electric motor range from size 63 up to size 225

 Open the catalog to page 1
LMG Series-2

BELL-HOUSING & COUPLING SIZING A GUIDE TO SELECT THE CORRECT BELL-HOUSING AND DRIVE COUPLING DATA REQUIRED - Electric motor power/motor size - Manufacturer and pump type TO VERIFY: 1 - Pump and motor shaft dimensions (see electric motor data sheet) 2 - Shaft and flange pump (see pump data sheet) Example: - Electric motor 2.2 kW - size 100-112 - Atos pump code PFE31 - Shaft 1 IEC Electric motor dimension Hydraulic pump dimension ø19.05 - key 4.76 Case A Solution with monobloc bell-housing series LMC/LDC Bell-Housing’s length calculation Pages 63 ÷ 69 for IEC Electric motor size 100-112 - LMC250...

 Open the catalog to page 2
LMG Series-3

BELL-HOUSING & COUPLING SIZING A GUIDE TO SELECT THE CORRECT BELL-HOUSING AND DRIVE COUPLING Coupling selection Motor half-coupling (see page 26) For IEC Electric motor size 100/112, the half-coupling is SGEA21M05060FG Spider (see page 31) For SGEA21, EGE2 - EGE2RR (choose spider material on the base of the application, oil, temperature and cycle machine, etc.) Pump half-coupling Choose the drilling code - see pages 18-19 for shaft 19.05 - key 4.76 - code: G01 Pump half-coupling length = BH length - THK Spider - THK Spigot LMC = 138 mm - 60 - 18 - 9.5 = 50.5 mm LMS = 148 mm - 60 - 18 - 9.5 =...

 Open the catalog to page 3
LMG Series-4

BELL-HOUSING & COUPLING SIZING Step Selection Software Select “BELL-HOUSING & COUPLING” Choose Manufacturer: select “Pump type” and “Pump model” Choose Coupling material Choose nr° of poles of “Electric motors”: select “Electric motors type” and “Elect

 Open the catalog to page 4
LMG Series-5

BELL-HOUSING & COUPLING SIZING Selection Software Step Push “CLICK HERE TO PROCEED”, then choose best solution for your application. Push “PREVIEW” to download the reports. Complete kit for: -IEC Electric Motor Size 160 -Pump Bosch Rexroth A10VSO45 shaft P Per errori ammissibili di quote senza tolleranze e per altre prescrizioni generali vedi UNI EN 22768-1/1996 - f For the permissible errors on the dimensions without tollerance and for other general specifications . See UNI EN 22768-1/1996 - f DESCRIPTION Monobloc Bellhousing Spider Motor Half Coupling Pump Half Coupling Tav./Sht. di/of Questo...

 Open the catalog to page 5
LMG Series-6

GENERAL INFORMATION Noise is a particularly pervasive problem so much so that there have been statutory regulations in place now for some years, designed to limit harmful occupational exposure. Many of the machines used in industry today are equipped with oil-hydraulic systems, which happen to be a major source of noise. THEORY AND DEFINITION OF NOISE From a health and hygiene standpoint, noise can be defined as an unpleasant and undesirable sound, or an unpleasant and annoying or intolerable auditory sensation (noise being any sound phenomena that may be accompanied by sensations of disturbance...

 Open the catalog to page 6
LMG Series-7

ASSEMBLY OF MOTOR AND PUMP UNIT Low noise bell-housing will help to attenuate the transmission of vibrations and the emission of noise generated by the system. Self-evidently, however, the mere adoption of a low noise bell-housing will achieve little unless the motor and pump are correctly installed on the machine or on the tank of the hydraulic power unit. Should be followed in order to achieve best possible results and correct installation: ® MOTOR AND PUMP UNIT MOUNTED HORIZONTALLY ON OIL TANK LID - The suction pipe attached to the pump must be rigid and fitted using a resilient bulkhead flange...

 Open the catalog to page 7
LMG Series-8

GENERAL INFORMATION PUMP INTERFACE CODES Valid configuration for bell-housing up to ø400 Bell-housing with nr. 2 holes at pump interface, aligned with through holes at motor interface. Spigot hole Bell-housing with nr. 4 holes at pump interface, aligned with thread holes at motor interface. Spigot hole Bell-housing with nr. 2 holes at pump interface + 22.5° compared to through holes at motor interface. Spigot hole Valid configuration for bell-housing from ø450 to ø660 Spigot hole Bell-housing with nr. 4 holes at pump interface + 22.5° compared to thread holes at motor interface.

 Open the catalog to page 8
LMG Series-11

LMG series IEC electric motor range from size 63 up to size 225

 Open the catalog to page 11
LMG Series-12

Bell-Housing - IEC electric motor range from size 63 up to size 225 Materials Temperature - Bell-housing: Pressure die casting Aluminium From -30 °C to +80 °C - Center ring: Galvanized Steel - Gasket: Special paper - Guarnital Note Compatibility with flUidS For temperatures outside this range contact MP Filtri Technical and Sales Department Modular bell-housing components compatible for use with: r - Mineral oils types HH-LL-HM-HR-HV-HC, to ISO 6743/4 standard - Water based emulsions types HFAE-HFAS, to ISO 6743/4 standard - Water glycol type HFC, to ISO 6743/4 standard: ask for anodized version...

 Open the catalog to page 12
LMG Series-13

Without centre ring allowing removal of half-coupling (which as a rule is keyed permanently to the pump shaft); motor mounting flange drilled with 4 clearance holes + 4 threaded holes. Used normally for vertically mounted motor and pump units with pump submerged in the oil tank. With centre ring allowing removal of half-coupling (which as a rule is keyed permanently to the pump shaft), motor mounting flange drilled with 4 clearance holes + 4 threaded holes. Normally used for motor and pump units mounted horizontally on the tank lid or on the machine for maximum ease of maintenance. With this...

 Open the catalog to page 13
LMG Series-14

Designation & Ordering code COMPLETE KIT (BELL-HOUSING & COUPLINGS) iSize Pump flange identification code Product revision code 4S 4 through holes + 4 threaded holes, motor interface without coupling removal ring 4E 4 through holes + 4 threaded holes, motor interface with coupling removal ring 8S 8 through holes, motor interface without coupling removal ring 8E 8 through holes, motor interface with coupling removal ring Bell-Housing series and size Pumps flange identification code Product revision code Note: - Bell-Housings with DI options are supplied complete with threaded closure plug. - Bell-Housing...

 Open the catalog to page 14
LMG Series-15

Dimensions Designation of pump flange and shaft ro 05 1 2 Spigot hole Pump half-coupling code FSZBR FSZFR FSZGR tapered 1:5 tapered 1:5 tapered 1:5

 Open the catalog to page 15

All MP Filtri catalogs and technical brochures

  1. LMS/LDS Series

    17  Pages

  2. LMC/LDC Series

    17  Pages

  3. ACCESSORIES

    28  Pages

  4. BELL HOUSING

    72  Pages

  5. COUPLINGS

    46  Pages

  6. SPIN-ON FILTERS

    76  Pages

  7. Suction Filters

    72  Pages

  8. Return Filters

    230  Pages

  9. FHD - DUPLEX

    17  Pages

  10. FHB - MANIFOLD

    16  Pages

  11. FHM - MANIFOLD

    21  Pages

  12. FHP

    19  Pages

  13. FMP

    14  Pages

  14. Spin-On Filter

    78  Pages

  15. Stainless Steel

    20  Pages

  16. LMP 124

    6  Pages

  17. MRSX

    12  Pages

  18. MSH

    4  Pages

  19. MPS

    8  Pages

  20. LMP 952 - 954

    6  Pages

  21. LMP 900 - 901

    4  Pages

  22. LMP MULTIPORT

    8  Pages

  23. FMP 039

    4  Pages

  24. SF2 250 - 350

    4  Pages

  25. FRI

    10  Pages

  26. MPI

    8  Pages

  27. MPH

    18  Pages

  28. MPT

    15  Pages

  29. MST

    4  Pages

  30. STR

    4  Pages

  31. RF2

    4  Pages

  32. MPF

    20  Pages

  33. LMP 400 - 430

    10  Pages

  34. LMP 210

    5  Pages

  35. FAS

    4  Pages

  36. SF2 500

    12  Pages

  37. SF2 250

    8  Pages

  38. SA - SAP

    10  Pages

  39. STR

    4  Pages

  40. Pressure filters

    116  Pages

  41. In-line filters

    108  Pages

  42. Accessories

    68  Pages

  43. Catalogue

    19  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.