FMP 039
4Pages

{{requestButtons}}

Catalog excerpts

FMP 039 - 1

Maximum pressure 110 bar Flow rates to 80 l/min Te c h n i c a l d a t a Filter housing (Materials) • Head: Anodized aluminium • Housing: Anodized aluminium • Bypass valve: Steel Filter housings Δp pressure drop The curves are plotted utilising mineral oil with density of 0,86 kg/dm3 to ISO 3968. Pressure • Working pressure: 110 bar (11 MPa) • Test pressure: 170 bar (17 MPa) • Burst pressure: 330 bar (33 MPa) • Pulse pressure fatigue test: 1.000.000 cycles with pressure from 0 to 110 bar (11 MPa) Δp varies proportionally with density. With bypass • From -25°C to +110°C Bypass valve • Opening pressure 6 bar ±10% • Other opening pressures on request. Δp Elements type • Microfibre filter elements series N: 20 bar • Wire mesh filter elements series N: 20 bar • Fluid flow through the filter element from OUT to IN. Flow rate l/min Valves Bypass valve pressure drop FMP 039 FILTERS ARE PROVIDED FOR VERTICAL MOUNTING Weights (kg) Length • FMP 039 Flow rate l/min Connections • FMP 039: In-line Inlet/Outlet PRESSURE FILTER Recommended maximum flow rate - Pressure drop of filter assembly equal to Δp 1,5 bar. - Oil kinematic viscosity 30 mm2/s (cSt). - Density 0,86 kg/dm3. - Connections of filter under test G 1/2”.

Open the catalog to page 1
FMP 039 - 2

Execution 1: Without indicator connection Execution 6: Double indicator connection (A - B) A: Closure cap with standard T2 steel. The position of the cap is reversible. B: Standard closure cap with plastic thread protection. If necessary, the second plug T2, see page 15 ordering information. Indicator port T2 Plug - A/F 30 Execution “6” Special connections on request PRESSURE FILTER Thread connections

Open the catalog to page 2
FMP 039 - 3

Item Description Filter assembly Filter element O-Ring for filter element Anti-extrusion ring O-Ring indicator PRESSURE FILTER Indicator connection plug

Open the catalog to page 3
FMP 039 - 4

Filter assembly Filter element Filter element Without indicator port With 2 indicators port* Inorganic microfibre 3 μm Inorganic microfibre 6 μm Without bypass With bypass Nominal Filtration 8 - Max filter element differential pressure Absolute filtration Inorganic Microfibre MP Filtri standard On request Indicator plug: Phosphated Steel plug T2 has to be ordered separately. Code Seal NBR Seal FPM PRESSURE FILTER For Clogging Indicator: See page 318 MP Filtri - The filter functions as described in this bulletin are valid exclusively for original MP Filtri filter elements and replacement...

Open the catalog to page 4

All MP Filtri catalogs and technical brochures

  1. LMS/LDS Series

    17 Pages

  2. LMC/LDC Series

    17 Pages

  3. LMG Series

    21 Pages

  4. ACCESSORIES

    28 Pages

  5. BELL HOUSING

    72 Pages

  6. COUPLINGS

    46 Pages

  7. Return Filters

    230 Pages

  8. FHD - DUPLEX

    17 Pages

  9. FHB - MANIFOLD

    16 Pages

  10. FHM - MANIFOLD

    21 Pages

  11. FHP

    19 Pages

  12. FMP

    14 Pages

  13. Spin-On Filter

    78 Pages

  14. LMP 124

    6 Pages

  15. MRSX

    12 Pages

  16. MSH

    4 Pages

  17. MPS

    8 Pages

  18. FRI

    10 Pages

  19. MPI

    8 Pages

  20. MPH

    18 Pages

  21. MPT

    15 Pages

  22. MST

    4 Pages

  23. STR

    4 Pages

  24. RF2

    4 Pages

  25. MPF

    20 Pages

  26. LMP 400 - 430

    10 Pages

  27. LMP 210

    5 Pages

  28. FAS

    4 Pages

  29. SF2 500

    12 Pages

  30. SF2 250

    8 Pages

  31. SA - SAP

    10 Pages

  32. STR

    4 Pages

  33. In-line filters

    108 Pages

  34. Accessories

    68 Pages

  35. Catalogue

    19 Pages